1
00:00:00,050 --> 00:00:01,770
In this lesson, we're going to explore

2
00:00:01,770 --> 00:00:03,540
the Characteristics, Capabilities,

3
00:00:03,540 --> 00:00:06,090
and Applications of Copper Media.

4
00:00:06,090 --> 00:00:08,039
Now, copper media has been the default type

5
00:00:08,039 --> 00:00:10,620
of cable used in our network for decades, which

6
00:00:10,620 --> 00:00:12,690
in turn has made them an indispensable part

7
00:00:12,690 --> 00:00:14,400
of our network infrastructure.

8
00:00:14,400 --> 00:00:18,030
So in this lesson, we're going to explore the 802.3 Standard

9
00:00:18,030 --> 00:00:19,410
that includes these specifications

10
00:00:19,410 --> 00:00:23,010
for Ethernet network protocols and its associated wiring.

11
00:00:23,010 --> 00:00:26,430
The 802.3 Standard is a collection of IEE Standards

12
00:00:26,430 --> 00:00:27,630
that define the physical layer

13
00:00:27,630 --> 00:00:29,880
and data link layer's media access control

14
00:00:29,880 --> 00:00:33,090
or MAC for a given wired Ethernet network.

15
00:00:33,090 --> 00:00:35,399
Now this 802.3 Standard is commonly used

16
00:00:35,399 --> 00:00:38,160
in local area networks and it provides a basis

17
00:00:38,160 --> 00:00:40,530
for the operation of that network.

18
00:00:40,530 --> 00:00:43,500
Inside of our wired networks, the most common type of cable

19
00:00:43,500 --> 00:00:46,590
that we're going to be using is known as a twisted pair cable.

20
00:00:46,590 --> 00:00:49,530
Now under the IEEE 802.3 Standard,

21
00:00:49,530 --> 00:00:51,120
there are numerous different types of cables

22
00:00:51,120 --> 00:00:53,820
that are going to be defined, including copper cables,

23
00:00:53,820 --> 00:00:57,510
like twisted pair cables, coaxial cables, twinaxial cables,

24
00:00:57,510 --> 00:01:00,510
and direct attach copper, as well as fiber optic cables

25
00:01:00,510 --> 00:01:02,250
and their specifications.

26
00:01:02,250 --> 00:01:04,379
So in this lesson, let's focus just

27
00:01:04,379 --> 00:01:06,780
on the copper cables, including twisted pair

28
00:01:06,780 --> 00:01:09,330
cables, coaxial cables, twinaxial cables,

29
00:01:09,330 --> 00:01:11,190
and direct attach copper.

30
00:01:11,190 --> 00:01:14,070
First, let's discuss twisted pair cables.

31
00:01:14,070 --> 00:01:16,320
Now, a twisted pair cable is a type of wiring

32
00:01:16,320 --> 00:01:17,400
in which two conductors

33
00:01:17,400 --> 00:01:20,250
of a single circuit are twisted together for the purpose

34
00:01:20,250 --> 00:01:22,530
of canceling out the electromagnetic interference

35
00:01:22,530 --> 00:01:26,220
or EMI from any of the external sources and crosstalk

36
00:01:26,220 --> 00:01:28,560
that might occur from neighboring cables.

37
00:01:28,560 --> 00:01:30,840
Now, twisted pair cables are the preferred method

38
00:01:30,840 --> 00:01:33,360
for transmitting both data and voice signals,

39
00:01:33,360 --> 00:01:34,680
and they can be used for both network

40
00:01:34,680 --> 00:01:36,810
and telecommunication services.

41
00:01:36,810 --> 00:01:38,850
By twisting the cables, the consistency

42
00:01:38,850 --> 00:01:40,650
of the data transmission is increased

43
00:01:40,650 --> 00:01:42,150
and its susceptibility to noise

44
00:01:42,150 --> 00:01:44,490
and interference is going to be reduced.

45
00:01:44,490 --> 00:01:45,540
There are two main types

46
00:01:45,540 --> 00:01:47,910
of twisted pair cables you need to be aware of.

47
00:01:47,910 --> 00:01:51,063
These are unshielded twisted pair cables or UTP

48
00:01:51,063 --> 00:01:54,240
and shielded twisted pair cables or STP.

49
00:01:54,240 --> 00:01:55,950
Now, unshielded twisted pair cables

50
00:01:55,950 --> 00:01:58,410
or UTP cables are the most common type

51
00:01:58,410 --> 00:02:00,420
of twisted pair cables that are being used

52
00:02:00,420 --> 00:02:02,670
in telecommunications and computer networks.

53
00:02:02,670 --> 00:02:06,180
The unshielded twisted pair cable is comprised of pairs

54
00:02:06,180 --> 00:02:07,920
of wires that are twisted together

55
00:02:07,920 --> 00:02:10,889
without additional shielding being added to that cable.

56
00:02:10,889 --> 00:02:14,460
This design makes UTP cables very lightweight, flexible,

57
00:02:14,460 --> 00:02:16,350
and cost effective for a variety

58
00:02:16,350 --> 00:02:18,300
of different applications, including most

59
00:02:18,300 --> 00:02:20,910
of our Ethernet based local area networks.

60
00:02:20,910 --> 00:02:22,260
Now, the lack of shielding inside

61
00:02:22,260 --> 00:02:24,690
of these cables does make our UTP cables smaller

62
00:02:24,690 --> 00:02:26,850
in diameter, easier for us to install,

63
00:02:26,850 --> 00:02:28,740
and overall, they're less expensive

64
00:02:28,740 --> 00:02:30,600
than shielded alternatives.

65
00:02:30,600 --> 00:02:32,730
On the other hand, shielded twisted pair

66
00:02:32,730 --> 00:02:35,820
or STP cables are designed with a layer of insulation

67
00:02:35,820 --> 00:02:39,480
or shielding made out of copper tape, a conducting polymer

68
00:02:39,480 --> 00:02:42,090
or a braided mesh of copper wires.

69
00:02:42,090 --> 00:02:43,860
This shielding adds a protective layer

70
00:02:43,860 --> 00:02:46,440
against the electromagnetic interference or EMI

71
00:02:46,440 --> 00:02:47,940
by allowing the STP cables

72
00:02:47,940 --> 00:02:50,010
to more effectively reduce their noise

73
00:02:50,010 --> 00:02:51,990
and improve their signal quality.

74
00:02:51,990 --> 00:02:54,540
These shielded twisted pair cables are commonly used

75
00:02:54,540 --> 00:02:56,100
in environments where there's a high degree

76
00:02:56,100 --> 00:02:58,650
of electromagnetic interferon because they can provide us

77
00:02:58,650 --> 00:03:01,620
with a more stable and secure network connection.

78
00:03:01,620 --> 00:03:04,290
As you can see, the UTP cables are available

79
00:03:04,290 --> 00:03:05,310
at a lower cost.

80
00:03:05,310 --> 00:03:06,960
They support easier installations

81
00:03:06,960 --> 00:03:08,580
and are more suitable for a wide range

82
00:03:08,580 --> 00:03:10,320
of common networking applications

83
00:03:10,320 --> 00:03:12,960
where electromagnetic interference is not a big concern

84
00:03:12,960 --> 00:03:14,490
in our organization.

85
00:03:14,490 --> 00:03:18,150
However, UTP cables are more susceptible to EMI

86
00:03:18,150 --> 00:03:20,850
and noise, which can then degrade the signal quality

87
00:03:20,850 --> 00:03:24,480
over longer distances or in individual environments.

88
00:03:24,480 --> 00:03:26,340
To counteract this, you should utilize

89
00:03:26,340 --> 00:03:27,960
a shielded twisted pair cable

90
00:03:27,960 --> 00:03:30,300
because it offers better protection against interference

91
00:03:30,300 --> 00:03:31,470
and crosstalk.

92
00:03:31,470 --> 00:03:34,290
This means that the STP cables are a better choice

93
00:03:34,290 --> 00:03:37,110
for environments with significant EMI being present,

94
00:03:37,110 --> 00:03:39,900
and this can also help us to maintain higher data rates

95
00:03:39,900 --> 00:03:43,950
over longer distances than if we're using a UTP cable.

96
00:03:43,950 --> 00:03:45,120
Now the biggest downside

97
00:03:45,120 --> 00:03:46,980
to using shielded twisted pair cables is

98
00:03:46,980 --> 00:03:48,930
that they're more expensive, they're bulkier,

99
00:03:48,930 --> 00:03:51,030
and they're more difficult to install due

100
00:03:51,030 --> 00:03:52,980
to that additional shielding that's being added

101
00:03:52,980 --> 00:03:54,480
into that design.

102
00:03:54,480 --> 00:03:56,430
Now, regardless of whether you use a shielded

103
00:03:56,430 --> 00:03:58,470
or an unshielded twisted pair cable,

104
00:03:58,470 --> 00:04:01,530
each cable will also be categorized using a number such

105
00:04:01,530 --> 00:04:06,530
as CAT 5, CAT 5e, CAT 6, CAT 6a, CAT 7, and CAT 8.

106
00:04:07,200 --> 00:04:08,670
Let's take a moment and break down each

107
00:04:08,670 --> 00:04:09,720
of these different categories

108
00:04:09,720 --> 00:04:11,940
in the 802.3 Ethernet standard

109
00:04:11,940 --> 00:04:15,120
to better understand their speed and distance limitations.

110
00:04:15,120 --> 00:04:17,160
Now, CAT 5 is the oldest category

111
00:04:17,160 --> 00:04:18,390
that you're probably still going to run

112
00:04:18,390 --> 00:04:20,700
across today out in the real world.

113
00:04:20,700 --> 00:04:23,490
CAT 5 cables only support data transfer speeds

114
00:04:23,490 --> 00:04:25,380
up to a hundred megabits per second

115
00:04:25,380 --> 00:04:26,670
with a maximum cable length

116
00:04:26,670 --> 00:04:29,010
of a hundred meters using frequencies of up

117
00:04:29,010 --> 00:04:30,720
to 100 megahertz.

118
00:04:30,720 --> 00:04:32,550
This type of cable is also referred

119
00:04:32,550 --> 00:04:37,550
to as a 100 BASE-T network or under the term fast Ethernet.

120
00:04:38,010 --> 00:04:41,460
CAT 5e or category five enhanced is an advancement

121
00:04:41,460 --> 00:04:44,010
over this older CAT 5 cable standard.

122
00:04:44,010 --> 00:04:46,710
CAT 5e will support data transfer speeds up

123
00:04:46,710 --> 00:04:49,800
to 1000 megabits per second, which is also equivalent

124
00:04:49,800 --> 00:04:53,220
to one Gigabit per second, and it has a maximum cable length

125
00:04:53,220 --> 00:04:55,350
of a hundred meters and uses a frequency

126
00:04:55,350 --> 00:04:57,030
of a hundred megahertz.

127
00:04:57,030 --> 00:05:00,180
Essentially, a CAT 5e cable contains more twist

128
00:05:00,180 --> 00:05:02,082
than the older CAT 5 cable, and this helps

129
00:05:02,082 --> 00:05:04,770
to reduce crosstalk as the data is being transmitted

130
00:05:04,770 --> 00:05:05,850
over that cable.

131
00:05:05,850 --> 00:05:08,790
And this in turn provides us with better signal integrity

132
00:05:08,790 --> 00:05:11,000
that allows us to support up to one Gigabit per second

133
00:05:11,000 --> 00:05:13,950
of speed instead of only supporting a hundred megabits

134
00:05:13,950 --> 00:05:15,150
per second of speed that

135
00:05:15,150 --> 00:05:17,580
that CAT 5 cable normally supported.

136
00:05:17,580 --> 00:05:21,540
This type of cable is also referred to as a 1000 BASE-T

137
00:05:21,540 --> 00:05:23,820
or Gigabit Ethernet connection.

138
00:05:23,820 --> 00:05:25,770
As we move into more modern cabling,

139
00:05:25,770 --> 00:05:28,920
we find our next category, which is known as CAT 6.

140
00:05:28,920 --> 00:05:31,920
Now, CAT 6 cables only support data transfer speeds of up

141
00:05:31,920 --> 00:05:34,680
to one Gigabit per second with a maximum cable length

142
00:05:34,680 --> 00:05:39,120
of 100 meters using frequencies of up to 250 megahertz.

143
00:05:39,120 --> 00:05:42,060
If your cable length is 55 meters or less, then you can

144
00:05:42,060 --> 00:05:43,740
also support data transfer speeds

145
00:05:43,740 --> 00:05:46,500
of up to 10 Gigabits per second instead.

146
00:05:46,500 --> 00:05:48,450
This type of cable is also referred to

147
00:05:48,450 --> 00:05:52,470
as 10G BASE-T when it's used under 55 meters

148
00:05:52,470 --> 00:05:55,080
and supports up to 10 Gigabits per second,

149
00:05:55,080 --> 00:05:58,260
and it's also referred to as 10 Gigabit Ethernet.

150
00:05:58,260 --> 00:06:00,630
But if you're using it as a hundred meters

151
00:06:00,630 --> 00:06:02,340
or less, you're going to refer to this

152
00:06:02,340 --> 00:06:06,330
as a 1000 BASE-T just like you did with CAT 5e,

153
00:06:06,330 --> 00:06:07,163
and this is going to be used

154
00:06:07,163 --> 00:06:09,480
to support a one Gigabit per second connection,

155
00:06:09,480 --> 00:06:12,810
and therefore it'll be referred to as Gigabit Ethernet.

156
00:06:12,810 --> 00:06:14,940
Next we have CAT 6a.

157
00:06:14,940 --> 00:06:18,480
Now CAT 6a is known as category six augmented.

158
00:06:18,480 --> 00:06:21,330
CAT 6a cables support data transfer speeds of up

159
00:06:21,330 --> 00:06:24,060
to 10 Gigabits per second with a maximum cable length

160
00:06:24,060 --> 00:06:28,170
of 100 meters using frequencies up to 500 megahertz.

161
00:06:28,170 --> 00:06:32,070
This type of cable is also referred to as 10G BASE-T

162
00:06:32,070 --> 00:06:34,200
or 10 Gigabit Ethernet.

163
00:06:34,200 --> 00:06:37,650
Basically, CAT 6a has increased the crosstalk protection

164
00:06:37,650 --> 00:06:39,750
over a CAT 6 cable, and this means

165
00:06:39,750 --> 00:06:42,420
that CAT 6a can support data transfer speeds of up

166
00:06:42,420 --> 00:06:46,080
to 10 Gigabits per second, even as far as a hundred meters,

167
00:06:46,080 --> 00:06:49,500
unlike CAT 6, which was limited to 55 meters in length

168
00:06:49,500 --> 00:06:52,590
when you want to operate at 10 Gigabits per second.

169
00:06:52,590 --> 00:06:55,500
The next cable type we have is CAT 7.

170
00:06:55,500 --> 00:06:57,900
CAT 7 cables are not actually recognized

171
00:06:57,900 --> 00:07:00,930
by TIA/EIA as a standard,

172
00:07:00,930 --> 00:07:02,850
but you're still going to find plenty of devices

173
00:07:02,850 --> 00:07:05,520
and cables that do support CAT 7.

174
00:07:05,520 --> 00:07:08,220
CAT 7 cables support data transfer speeds of up

175
00:07:08,220 --> 00:07:10,980
to 10 Gigabits per second with a maximum cable length

176
00:07:10,980 --> 00:07:14,220
of 100 meters just like CAT 6a does.

177
00:07:14,220 --> 00:07:15,450
The difference here is

178
00:07:15,450 --> 00:07:17,940
that CAT 6a only supported frequencies up

179
00:07:17,940 --> 00:07:19,470
to 500 megahertz,

180
00:07:19,470 --> 00:07:22,190
but CAT 7 supports frequencies all the way up

181
00:07:22,190 --> 00:07:24,360
to 600 megahertz instead.

182
00:07:24,360 --> 00:07:28,110
CAT 7 cables are also used to support 10G BASE-T

183
00:07:28,110 --> 00:07:30,900
or 10 Gigabit Ethernet networks.

184
00:07:30,900 --> 00:07:34,200
The final one we have when it comes to CATs is CAT 8.

185
00:07:34,200 --> 00:07:36,690
CAT 8 is a modern advanced standard

186
00:07:36,690 --> 00:07:38,310
that supports data transfer speeds of up

187
00:07:38,310 --> 00:07:41,250
to 40 Gigabits per second with a maximum cable length

188
00:07:41,250 --> 00:07:42,720
of only 30 meters,

189
00:07:42,720 --> 00:07:45,630
and it uses frequencies up to 2000 megahertz, which is

190
00:07:45,630 --> 00:07:48,870
also considered to be two gigahertz in frequency.

191
00:07:48,870 --> 00:07:50,880
Now, the CAT 8 cable was designed for use

192
00:07:50,880 --> 00:07:53,130
in data centers and enterprise applications

193
00:07:53,130 --> 00:07:55,380
where high speed data transfer was crucial

194
00:07:55,380 --> 00:07:57,180
and shorter distances such

195
00:07:57,180 --> 00:07:59,220
as between two servers inside of a rack or

196
00:07:59,220 --> 00:08:01,260
between two neighboring server racks could

197
00:08:01,260 --> 00:08:03,540
be used by using CAT 8 cables instead

198
00:08:03,540 --> 00:08:05,280
of using a fiber cable.

199
00:08:05,280 --> 00:08:06,600
Now the second thing we need to look

200
00:08:06,600 --> 00:08:08,970
at is to look at coaxial cables.

201
00:08:08,970 --> 00:08:11,370
Now, coaxial cables also known simply

202
00:08:11,370 --> 00:08:14,100
as coax, has been a fundamental part of networking

203
00:08:14,100 --> 00:08:16,290
and broadcasting for decades.

204
00:08:16,290 --> 00:08:18,780
Coaxial cables consist of a single copper conductor

205
00:08:18,780 --> 00:08:20,700
at its core with an insulating layer

206
00:08:20,700 --> 00:08:23,040
and a conductive shield wrapped around it.

207
00:08:23,040 --> 00:08:24,960
Originally, most people were introduced

208
00:08:24,960 --> 00:08:27,570
to coaxial cables from their use in broadband systems

209
00:08:27,570 --> 00:08:29,250
like cable television systems

210
00:08:29,250 --> 00:08:31,620
because these cables could carry numerous television

211
00:08:31,620 --> 00:08:35,580
channels into our homes over a single coaxial cable line.

212
00:08:35,580 --> 00:08:38,250
These days though, these same coaxial cables are

213
00:08:38,250 --> 00:08:40,559
also being used to carry data at high speeds

214
00:08:40,559 --> 00:08:42,330
over longer distances.

215
00:08:42,330 --> 00:08:45,720
In most residential installations, the RG-6 coaxial cable

216
00:08:45,720 --> 00:08:48,270
will be used to support faster internet speeds when

217
00:08:48,270 --> 00:08:49,980
you're using a cable modem.

218
00:08:49,980 --> 00:08:53,370
These RG-6 cables have a heavier center copper core,

219
00:08:53,370 --> 00:08:54,990
which makes it great for high bandwidth

220
00:08:54,990 --> 00:08:57,780
and higher frequency applications like cable modems

221
00:08:57,780 --> 00:09:00,120
and digital video transmission systems.

222
00:09:00,120 --> 00:09:02,370
In the old days, there was actually an older standard

223
00:09:02,370 --> 00:09:05,370
for coaxial cables known as RG-59,

224
00:09:05,370 --> 00:09:07,110
but this isn't commonly used anymore

225
00:09:07,110 --> 00:09:09,540
because it is an inner copper core that's much thinner

226
00:09:09,540 --> 00:09:11,100
than an RG-6 cable.

227
00:09:11,100 --> 00:09:14,310
And these older RG-59 cables can only really be used

228
00:09:14,310 --> 00:09:17,340
in analog video and closed circuit television installations

229
00:09:17,340 --> 00:09:18,660
because of their lower bandwidth

230
00:09:18,660 --> 00:09:20,970
and lower frequency capabilities.

231
00:09:20,970 --> 00:09:21,803
Now, when it comes

232
00:09:21,803 --> 00:09:24,540
to coaxial cables, the data transfer speeds associated

233
00:09:24,540 --> 00:09:27,420
with an RG-6 coaxial cable really does depend

234
00:09:27,420 --> 00:09:29,460
on the specific application you're using,

235
00:09:29,460 --> 00:09:32,610
but most modern coaxial cables can support speeds of up

236
00:09:32,610 --> 00:09:36,660
to one Gigabit per second at a distance of up to 300 meters.

237
00:09:36,660 --> 00:09:39,180
Now, a newer form of coaxial cabling is referred

238
00:09:39,180 --> 00:09:42,990
to as direct attach copper or DAC cables.

239
00:09:42,990 --> 00:09:45,120
Direct attach copper cables are a form

240
00:09:45,120 --> 00:09:47,400
of fixed assembly copper cabling that's used

241
00:09:47,400 --> 00:09:50,370
to connect switches, routers, firewalls, and servers,

242
00:09:50,370 --> 00:09:52,890
and they're primarily used within server racks inside

243
00:09:52,890 --> 00:09:55,050
of a data center or within close range

244
00:09:55,050 --> 00:09:57,300
of your network infrastructure's hardware.

245
00:09:57,300 --> 00:09:59,490
These direct attach copper cables come

246
00:09:59,490 --> 00:10:01,920
with connectors already attach when you purchase them,

247
00:10:01,920 --> 00:10:04,110
and they're really favored for their cost effectiveness

248
00:10:04,110 --> 00:10:06,360
and reduced power consumption as compared

249
00:10:06,360 --> 00:10:09,510
to fiber optics when they're used for short distances.

250
00:10:09,510 --> 00:10:12,690
Direct attach cables can operate at a maximum data speed

251
00:10:12,690 --> 00:10:15,330
of a hundred Gigabits per second at 15 meters

252
00:10:15,330 --> 00:10:17,610
or less when using an active cable

253
00:10:17,610 --> 00:10:20,430
or 100 Gigabits per second at seven meters

254
00:10:20,430 --> 00:10:23,160
or less when you're using passive cables.

255
00:10:23,160 --> 00:10:24,810
These direct attach cables can

256
00:10:24,810 --> 00:10:26,700
also support high speed data transmissions

257
00:10:26,700 --> 00:10:28,650
with speeds of 10 Gigabits per second,

258
00:10:28,650 --> 00:10:29,880
40 Gigabits per second,

259
00:10:29,880 --> 00:10:32,700
or up to a hundred Gigabits per second depending

260
00:10:32,700 --> 00:10:34,110
on the distance being covered,

261
00:10:34,110 --> 00:10:35,400
and this makes them well suited

262
00:10:35,400 --> 00:10:36,960
for interconnect applications

263
00:10:36,960 --> 00:10:40,800
between two servers, routers, switches, or other devices.

264
00:10:40,800 --> 00:10:42,840
Another coaxial cable you may hear mentioned

265
00:10:42,840 --> 00:10:45,600
is what we refer to as a twinaxial cable.

266
00:10:45,600 --> 00:10:48,150
Now, a twinaxial cable is often a component

267
00:10:48,150 --> 00:10:50,220
of a direct attach copper assembly,

268
00:10:50,220 --> 00:10:53,130
and it's considered another specialized form of cabling.

269
00:10:53,130 --> 00:10:55,050
Unlike a traditional coaxial cable,

270
00:10:55,050 --> 00:10:56,730
a twinaxial cable consists

271
00:10:56,730 --> 00:10:59,160
of two separate insulated copper conductors

272
00:10:59,160 --> 00:11:02,130
that are run parallel within the same outer shield.

273
00:11:02,130 --> 00:11:04,500
This twinaxial cable design is optimized

274
00:11:04,500 --> 00:11:06,540
for short range, high speed differential

275
00:11:06,540 --> 00:11:08,250
signaling applications.

276
00:11:08,250 --> 00:11:11,490
Twinaxial cables are commonly used for SFP+,

277
00:11:11,490 --> 00:11:14,010
which is a small form factor pluggable plus

278
00:11:14,010 --> 00:11:16,830
or QSFP, which is a quad small

279
00:11:16,830 --> 00:11:19,680
form factor pluggable direct attach application

280
00:11:19,680 --> 00:11:22,050
between two different routers or switches.

281
00:11:22,050 --> 00:11:24,690
These twinaxial cables provide a reliable solution

282
00:11:24,690 --> 00:11:26,370
for high frequency transmissions

283
00:11:26,370 --> 00:11:30,030
and offer superior signal integrity over shorter distances.

284
00:11:30,030 --> 00:11:32,167
As compared to a traditional unshielded cable,

285
00:11:32,167 --> 00:11:34,170
twinaxial cables are less susceptible

286
00:11:34,170 --> 00:11:35,850
to electromagnetic interference,

287
00:11:35,850 --> 00:11:37,260
which is a significant advantage

288
00:11:37,260 --> 00:11:40,440
in tightly packed data centers where signal interference can

289
00:11:40,440 --> 00:11:42,840
become a major issue for your network.

290
00:11:42,840 --> 00:11:45,480
These twinaxial cables can support data transfer speeds

291
00:11:45,480 --> 00:11:48,690
of 10 Gigabits per second, 25 Gigabits per second,

292
00:11:48,690 --> 00:11:51,930
40 Gigabits per second, or 100 Gigabits per second

293
00:11:51,930 --> 00:11:54,000
at a distance of up to 100 meters

294
00:11:54,000 --> 00:11:55,920
for the 10 Gigabit per second cables,

295
00:11:55,920 --> 00:11:57,330
or as short as seven meters

296
00:11:57,330 --> 00:11:59,910
for the 100 Gigabit per second cables.

297
00:11:59,910 --> 00:12:01,830
The last thing we need to discuss is the difference

298
00:12:01,830 --> 00:12:04,560
between plenum and non-plenum cables.

299
00:12:04,560 --> 00:12:06,090
Now, plenum cables are designed

300
00:12:06,090 --> 00:12:08,040
with fire-retardant plastic jackets

301
00:12:08,040 --> 00:12:11,580
that are made from materials such as PVC or FEP.

302
00:12:11,580 --> 00:12:13,800
PVC is poly vinyl chloride,

303
00:12:13,800 --> 00:12:16,620
and FEP is Fluorinated Ethylene Propylene.

304
00:12:16,620 --> 00:12:18,660
This is used to prevent flames from spreading

305
00:12:18,660 --> 00:12:20,220
and reduces the amount of smoke produced

306
00:12:20,220 --> 00:12:22,290
during the fire of those cables.

307
00:12:22,290 --> 00:12:24,510
These characteristics are essential for the cables

308
00:12:24,510 --> 00:12:25,740
that run in the plenum spaces

309
00:12:25,740 --> 00:12:28,110
of our buildings, which are those areas typically used

310
00:12:28,110 --> 00:12:30,600
to route air circulating for heating, ventilation,

311
00:12:30,600 --> 00:12:32,400
and air conditioning systems.

312
00:12:32,400 --> 00:12:35,040
Since these spaces have an abundant supply of oxygen

313
00:12:35,040 --> 00:12:38,010
and can facilitate the rapid spread of fire, these cables

314
00:12:38,010 --> 00:12:39,630
that are installed here must adhere

315
00:12:39,630 --> 00:12:41,430
to strict fire safety standards,

316
00:12:41,430 --> 00:12:43,710
and that's why we use plenum-rated cables

317
00:12:43,710 --> 00:12:45,540
because these plenum-rated cables meet

318
00:12:45,540 --> 00:12:46,650
the stringent requirements

319
00:12:46,650 --> 00:12:49,080
of the National Fire Protection Association

320
00:12:49,080 --> 00:12:51,120
and the National Electrical Code.

321
00:12:51,120 --> 00:12:53,760
Although they are more expensive, their use is critical

322
00:12:53,760 --> 00:12:56,220
in minimizing the risks associated with fire and smoke

323
00:12:56,220 --> 00:12:59,340
in building spaces where air circulation can occur outside

324
00:12:59,340 --> 00:13:00,630
of your duct work.

325
00:13:00,630 --> 00:13:01,860
Now, non-plenum cables

326
00:13:01,860 --> 00:13:04,050
on the other hand, are what we use most of the time

327
00:13:04,050 --> 00:13:05,820
in our home office networks.

328
00:13:05,820 --> 00:13:07,800
Non-plenum cables are not designed

329
00:13:07,800 --> 00:13:10,140
with the same stringent fire-retardant properties

330
00:13:10,140 --> 00:13:12,090
and therefore they're not suitable for use

331
00:13:12,090 --> 00:13:13,650
in plenum spaces.

332
00:13:13,650 --> 00:13:15,690
Typically, these cables have jackets made

333
00:13:15,690 --> 00:13:17,160
from less expensive materials

334
00:13:17,160 --> 00:13:20,040
that do not have enhanced fire-resistant characteristics

335
00:13:20,040 --> 00:13:21,960
of those plenum-rated cables.

336
00:13:21,960 --> 00:13:24,180
These non-plenum cables are typically used

337
00:13:24,180 --> 00:13:27,090
in spaces where there's no environmental air return, such as

338
00:13:27,090 --> 00:13:28,830
between walls, in conduit,

339
00:13:28,830 --> 00:13:30,480
and in other areas where the potential

340
00:13:30,480 --> 00:13:34,110
for fire to propagate through open air spaces is much lower.

341
00:13:34,110 --> 00:13:35,400
While they're more cost effective

342
00:13:35,400 --> 00:13:37,710
than plenum cables, they do produce more smoke

343
00:13:37,710 --> 00:13:40,260
and toxic fumes when they're exposed to flame,

344
00:13:40,260 --> 00:13:43,170
and this makes them a really bad choice for any areas

345
00:13:43,170 --> 00:13:44,370
that could contribute to the spread

346
00:13:44,370 --> 00:13:45,990
of fire throughout a building.

347
00:13:45,990 --> 00:13:46,823
For installations

348
00:13:46,823 --> 00:13:48,930
that don't require the stringent fire safety standards

349
00:13:48,930 --> 00:13:51,840
of plenum-rated cables though, non-plenum cables provide

350
00:13:51,840 --> 00:13:55,020
a practical and economical solution for us to use.

351
00:13:55,020 --> 00:13:57,150
Now remember, there are a few different ways for us

352
00:13:57,150 --> 00:13:59,250
to categorize our copper cables.

353
00:13:59,250 --> 00:14:00,960
First, we can categorize them

354
00:14:00,960 --> 00:14:03,390
as either twisted pair or coaxial.

355
00:14:03,390 --> 00:14:04,470
Then if we're looking

356
00:14:04,470 --> 00:14:06,780
at twisted pair cables, we classify them

357
00:14:06,780 --> 00:14:09,330
as either shielded or unshielded twisted pair,

358
00:14:09,330 --> 00:14:12,300
and then we assign them a CAT number like CAT 5,

359
00:14:12,300 --> 00:14:16,650
CAT 5e, CAT 6, CAT 6a, CAT 7, or CAT 8.

360
00:14:16,650 --> 00:14:19,620
Then we finally can classify them as either being plenum

361
00:14:19,620 --> 00:14:21,720
or non-plenum-rated cables.

362
00:14:21,720 --> 00:14:23,910
On the other hand, if we're categorizing our cable

363
00:14:23,910 --> 00:14:26,070
as coaxial cable, we can then determine

364
00:14:26,070 --> 00:14:27,960
if it's a standard coaxial cable,

365
00:14:27,960 --> 00:14:31,350
a direct attach copper cable or a twinaxial cable

366
00:14:31,350 --> 00:14:34,050
to best classify its capabilities, limitations,

367
00:14:34,050 --> 00:14:35,400
and use cases.

368
00:14:35,400 --> 00:14:37,470
When it comes to copper media, it's important

369
00:14:37,470 --> 00:14:38,760
that you remember the basic speed

370
00:14:38,760 --> 00:14:40,560
and distance for each type of cable.

371
00:14:40,560 --> 00:14:42,150
So let's review those one more time

372
00:14:42,150 --> 00:14:44,010
before we end this lesson.

373
00:14:44,010 --> 00:14:48,450
CAT 5 cables can go 100 meters at 100 megabits per second.

374
00:14:48,450 --> 00:14:52,680
CAT 5e cables can go 100 meters at one Gigabit per second.

375
00:14:52,680 --> 00:14:56,340
CAT 6 cables can go 100 meters at one Gigabit per second,

376
00:14:56,340 --> 00:14:59,610
or 55 meters at 10 Gigabits per second.

377
00:14:59,610 --> 00:15:03,750
CAT 6a cables can do 100 meters at 10 Gigabits per second.

378
00:15:03,750 --> 00:15:07,440
CAT 7 cables can do 100 meters at 10 Gigabits per second,

379
00:15:07,440 --> 00:15:10,650
and CAT 8 cables can do about 30 meters at 25

380
00:15:10,650 --> 00:15:12,660
to 40 Gigabits per second.

381
00:15:12,660 --> 00:15:15,480
Now, as a quick reminder, all these CAT cables are limited

382
00:15:15,480 --> 00:15:17,370
to a hundred meters in length except

383
00:15:17,370 --> 00:15:19,890
for CAT 6, which is limited to 55 meters,

384
00:15:19,890 --> 00:15:21,720
if you want to provide the maximum speed

385
00:15:21,720 --> 00:15:23,310
of 10 Gigabits per second

386
00:15:23,310 --> 00:15:26,460
and CAT 8, which is limited to 30 meters.

387
00:15:26,460 --> 00:15:28,860
When it comes to speed, you can start with CAT 5

388
00:15:28,860 --> 00:15:31,290
at 100 megabits per second and then step up

389
00:15:31,290 --> 00:15:33,930
by a factor of 10 as you move up the scale.

390
00:15:33,930 --> 00:15:36,870
So CAT 5 is 100 megabits per second,

391
00:15:36,870 --> 00:15:40,020
but CAT 5e is 1000 megabits per second, which is

392
00:15:40,020 --> 00:15:42,540
also written as one Gigabit per second.

393
00:15:42,540 --> 00:15:45,870
CAT 6 is either one Gigabit per second, like CAT 5e,

394
00:15:45,870 --> 00:15:48,470
or you can reach 10 Gigabits per second with a cable

395
00:15:48,470 --> 00:15:51,540
at 55 meters or less, which again increases

396
00:15:51,540 --> 00:15:54,000
by a factor of 10 in terms of speed.

397
00:15:54,000 --> 00:15:57,120
CAT 6a is always going to be 10 Gigabits per second,

398
00:15:57,120 --> 00:16:00,240
which is 10 times higher than CAT 5e and CAT 6

399
00:16:00,240 --> 00:16:02,640
with that longer 100 meter cable.

400
00:16:02,640 --> 00:16:03,990
And CAT 7 will remain

401
00:16:03,990 --> 00:16:06,480
at 10 Gigabits per second, just like CAT 6.

402
00:16:06,480 --> 00:16:09,330
But then when we go to CAT 8, it increases again,

403
00:16:09,330 --> 00:16:11,760
but this time it goes from 10 Gigabits per second

404
00:16:11,760 --> 00:16:14,670
to 25 or 40 Gigabits per second depending on

405
00:16:14,670 --> 00:16:16,020
that cable length.

406
00:16:16,020 --> 00:16:18,150
On the coaxial cable side, you'll find

407
00:16:18,150 --> 00:16:21,110
that a traditional RG-6 coaxial cable can support speeds

408
00:16:21,110 --> 00:16:23,610
of up to one Gigabit per second added length

409
00:16:23,610 --> 00:16:25,170
of around 300 meters.

410
00:16:25,170 --> 00:16:28,080
Twinaxial cables have a much shorter distance

411
00:16:28,080 --> 00:16:31,050
of only 10 meters, but it does support much higher speeds

412
00:16:31,050 --> 00:16:34,110
by going up to 10 Gigabits per second or more.

413
00:16:34,110 --> 00:16:35,880
Direct attach cables are the newest

414
00:16:35,880 --> 00:16:38,730
and most modern copper cable type, and they support speeds

415
00:16:38,730 --> 00:16:42,480
of up to 100 Gigabits per second at a distance of 15 meters

416
00:16:42,480 --> 00:16:45,810
for active cables and only up to a distance of seven meters

417
00:16:45,810 --> 00:16:48,930
for passive cables at 100 Gigabits per second.

418
00:16:48,930 --> 00:16:51,180
Now, I know that was a ton of facts and figures,

419
00:16:51,180 --> 00:16:53,400
and I do recommend that you take a little time offline

420
00:16:53,400 --> 00:16:55,170
to study these numbers from your notes

421
00:16:55,170 --> 00:16:56,310
because they will be important

422
00:16:56,310 --> 00:16:58,320
during your troubleshooting and network design work

423
00:16:58,320 --> 00:17:00,780
as a network technician out in the real world.

424
00:17:00,780 --> 00:17:02,700
Even though much of the world is slowly moving over

425
00:17:02,700 --> 00:17:05,490
to fiber, copper media will remain a vital part

426
00:17:05,490 --> 00:17:07,859
of our network infrastructure for years to come

427
00:17:07,859 --> 00:17:09,630
because it provides us with a versatility

428
00:17:09,630 --> 00:17:12,329
and robustness required for various networking needs

429
00:17:12,329 --> 00:17:14,670
at a lower price and is much easier to install

430
00:17:14,670 --> 00:17:16,500
and maintain for many applications

431
00:17:16,500 --> 00:17:18,782
and workplace environments than fiber is.

