1
00:00:00,150 --> 00:00:00,983
In this video,

2
00:00:00,983 --> 00:00:03,510
we're going to discuss the various issues you may experience

3
00:00:03,510 --> 00:00:06,810
with connectivity that are caused by cable signaling issues.

4
00:00:06,810 --> 00:00:10,620
This includes attenuation, interference, and decibel loss.

5
00:00:10,620 --> 00:00:12,450
First, we have attenuation.

6
00:00:12,450 --> 00:00:15,240
Attenuation is a loss of signal strength on a network cable

7
00:00:15,240 --> 00:00:17,700
or connection over the length of the cable.

8
00:00:17,700 --> 00:00:19,590
This is a common occurrence in both wired

9
00:00:19,590 --> 00:00:20,910
and wireless connections,

10
00:00:20,910 --> 00:00:22,680
but for right now, we're going to focus

11
00:00:22,680 --> 00:00:24,570
on wired connections only.

12
00:00:24,570 --> 00:00:27,120
When we're using a copper cable, such as a twisted pair

13
00:00:27,120 --> 00:00:28,470
or a coaxial cable,

14
00:00:28,470 --> 00:00:30,600
we're going to transmit data across the cable

15
00:00:30,600 --> 00:00:33,120
by sending electrical signals of varying voltages

16
00:00:33,120 --> 00:00:35,340
that represent our binary ones and zeros

17
00:00:35,340 --> 00:00:36,810
of the data being sent.

18
00:00:36,810 --> 00:00:38,760
The copper conduit inside these cables

19
00:00:38,760 --> 00:00:40,050
are going to carry those signals,

20
00:00:40,050 --> 00:00:43,110
but that copper has a natural level of resistance,

21
00:00:43,110 --> 00:00:44,790
and the longer the cable becomes,

22
00:00:44,790 --> 00:00:46,590
the higher that resistance becomes,

23
00:00:46,590 --> 00:00:48,120
and the data has a harder time

24
00:00:48,120 --> 00:00:50,010
traveling down the copper cable.

25
00:00:50,010 --> 00:00:51,690
This causes the signal to weaken

26
00:00:51,690 --> 00:00:55,080
or attenuate as it travels along the distance of the cable.

27
00:00:55,080 --> 00:00:57,660
When you learned about twisted pair cable, I told you

28
00:00:57,660 --> 00:01:00,750
that we had this maximum distance of about a hundred meters.

29
00:01:00,750 --> 00:01:03,120
Now, this is caused because of attenuation.

30
00:01:03,120 --> 00:01:04,980
Once you get further than a hundred meters,

31
00:01:04,980 --> 00:01:07,740
the signal's going to weaken and become unreliable.

32
00:01:07,740 --> 00:01:10,110
With coaxial cables, you have more shielding

33
00:01:10,110 --> 00:01:11,640
or insulation around it.

34
00:01:11,640 --> 00:01:13,320
Therefore, you can reach distances

35
00:01:13,320 --> 00:01:15,150
of up to about 500 meters.

36
00:01:15,150 --> 00:01:16,980
But when you pass that limit,

37
00:01:16,980 --> 00:01:19,140
the attenuation again becomes too much,

38
00:01:19,140 --> 00:01:21,870
and the signal strength weakens to an unusable level.

39
00:01:21,870 --> 00:01:24,510
So distance is going to be our main factor when we're dealing

40
00:01:24,510 --> 00:01:27,150
with attenuation, but there's a couple other factors

41
00:01:27,150 --> 00:01:29,190
that can affect your signal strength too.

42
00:01:29,190 --> 00:01:31,710
This includes frequencies that are used by the connection,

43
00:01:31,710 --> 00:01:33,000
the noise in the environment,

44
00:01:33,000 --> 00:01:35,220
and the physical surroundings near the connection.

45
00:01:35,220 --> 00:01:36,360
You see, all networking

46
00:01:36,360 --> 00:01:39,360
and electrical cables operate at a specific frequency.

47
00:01:39,360 --> 00:01:41,550
For example, power cables in a residential

48
00:01:41,550 --> 00:01:44,520
or office setting are usually going to operate at 60 hertz

49
00:01:44,520 --> 00:01:46,140
in the United States and Canada.

50
00:01:46,140 --> 00:01:47,730
But if you're in another country,

51
00:01:47,730 --> 00:01:49,920
it may operate at 50 hertz.

52
00:01:49,920 --> 00:01:50,940
Ethernet cables though,

53
00:01:50,940 --> 00:01:52,800
operate at different frequencies too.

54
00:01:52,800 --> 00:01:55,020
If you're using a CAT 5e cable, for instance,

55
00:01:55,020 --> 00:01:57,450
it uses a frequency of a hundred megahertz.

56
00:01:57,450 --> 00:01:59,340
Well, a CAT 6 cable is going to use a frequency

57
00:01:59,340 --> 00:02:01,050
of 250 megahertz.

58
00:02:01,050 --> 00:02:04,470
A CAT 6a cable uses a frequency of 500 megahertz,

59
00:02:04,470 --> 00:02:07,980
and a CAT 7 cable uses a frequency of 600 megahertz.

60
00:02:07,980 --> 00:02:10,229
Now, in general, the higher the frequency,

61
00:02:10,229 --> 00:02:11,400
the higher the bandwidth

62
00:02:11,400 --> 00:02:13,830
that a particular cable is going to be able to produce.

63
00:02:13,830 --> 00:02:16,560
This is because each hert is one cycle per second

64
00:02:16,560 --> 00:02:19,740
in frequency, and so the more cycles you have in a second,

65
00:02:19,740 --> 00:02:21,360
the more times you could put a one

66
00:02:21,360 --> 00:02:23,160
or a zero down that cable.

67
00:02:23,160 --> 00:02:24,723
So if you're going to use a network cable

68
00:02:24,723 --> 00:02:26,910
that uses a frequency similar to the frequencies

69
00:02:26,910 --> 00:02:29,460
of the cable surrounding it, you can have something known

70
00:02:29,460 --> 00:02:32,970
as crosstalk or interference that's going to occur.

71
00:02:32,970 --> 00:02:34,470
Now, this brings us to the concept

72
00:02:34,470 --> 00:02:36,300
of noise in your environment.

73
00:02:36,300 --> 00:02:38,070
If there's additional electrical frequency

74
00:02:38,070 --> 00:02:40,560
or radio frequency noise in your area,

75
00:02:40,560 --> 00:02:43,080
this can cause your network cables to have problems

76
00:02:43,080 --> 00:02:45,030
and increase the rate of attenuation

77
00:02:45,030 --> 00:02:47,640
and decreasing your associated signal strength.

78
00:02:47,640 --> 00:02:49,500
For example, if you have a network cable

79
00:02:49,500 --> 00:02:51,720
that's located near an area where heavy machinery

80
00:02:51,720 --> 00:02:54,660
or power generators are being used, this will create noise

81
00:02:54,660 --> 00:02:57,180
and signal interference that will decrease the distance

82
00:02:57,180 --> 00:02:58,980
that cable is going to be able to support

83
00:02:58,980 --> 00:03:00,630
because there's more attenuation

84
00:03:00,630 --> 00:03:03,030
and more noise across that signal.

85
00:03:03,030 --> 00:03:04,590
Finally, the physical surroundings

86
00:03:04,590 --> 00:03:06,000
you're using your copper cables in

87
00:03:06,000 --> 00:03:08,040
can also increase your attenuation.

88
00:03:08,040 --> 00:03:10,440
Things like temperature, the construction of the walls

89
00:03:10,440 --> 00:03:13,290
or other barriers, and the type of wire insulation itself,

90
00:03:13,290 --> 00:03:15,780
can all negatively affect your signal strength.

91
00:03:15,780 --> 00:03:17,700
If you have freezing temperatures, for instance,

92
00:03:17,700 --> 00:03:19,620
your copper cables will become more brittle

93
00:03:19,620 --> 00:03:22,620
and inflexible, which in turn slows down the connection

94
00:03:22,620 --> 00:03:24,270
and attenuates the signal.

95
00:03:24,270 --> 00:03:26,040
When you're experiencing hotter temperatures,

96
00:03:26,040 --> 00:03:27,750
the signals can actually overheat

97
00:03:27,750 --> 00:03:30,180
and the network cable could potentially even catch fire

98
00:03:30,180 --> 00:03:32,070
if the outside plastic melts away

99
00:03:32,070 --> 00:03:35,250
and the inside wire becomes exposed to flammable materials.

100
00:03:35,250 --> 00:03:37,140
For this reason, it's always important

101
00:03:37,140 --> 00:03:38,730
to have well insulated wires

102
00:03:38,730 --> 00:03:41,040
and attempt to maintain the proper temperature control

103
00:03:41,040 --> 00:03:42,690
that your network connection needs

104
00:03:42,690 --> 00:03:45,750
to maintain a strong signal and minimal attenuation.

105
00:03:45,750 --> 00:03:49,020
So, what can you do when you experience attenuation?

106
00:03:49,020 --> 00:03:51,750
First, you can make sure you're using the proper cables

107
00:03:51,750 --> 00:03:54,180
for the physical environment you're operating within.

108
00:03:54,180 --> 00:03:55,470
If you're operating in a hotter

109
00:03:55,470 --> 00:03:57,600
or colder environment, you may need to switch

110
00:03:57,600 --> 00:03:59,250
to shielded twisted pair instead

111
00:03:59,250 --> 00:04:01,470
of unshielded twisted pair, for example.

112
00:04:01,470 --> 00:04:03,690
Second, you can shorten the distance.

113
00:04:03,690 --> 00:04:05,490
While the maximum length is a hundred meters

114
00:04:05,490 --> 00:04:06,390
for these cables,

115
00:04:06,390 --> 00:04:07,950
it's a good idea to use cables

116
00:04:07,950 --> 00:04:09,330
that are a bit shorter than that

117
00:04:09,330 --> 00:04:11,430
to ensure you always have a good, clear signal

118
00:04:11,430 --> 00:04:13,080
on all of your connections.

119
00:04:13,080 --> 00:04:15,930
Personally, I tend to implement an 80 meter limit

120
00:04:15,930 --> 00:04:19,079
on all of my twisted pair cables inside my networks.

121
00:04:19,079 --> 00:04:22,110
Third, you can use an amplifier or a repeater.

122
00:04:22,110 --> 00:04:23,370
These are layer one devices

123
00:04:23,370 --> 00:04:26,280
that take in the signal on one end, boost up the signal

124
00:04:26,280 --> 00:04:28,380
and retransmit it out the other side.

125
00:04:28,380 --> 00:04:29,990
This means if I need to run a twisted pair

126
00:04:29,990 --> 00:04:33,550
of cable over 150 meters, I could use a 75

127
00:04:33,550 --> 00:04:36,390
or 80 meter cable connected to a repeater,

128
00:04:36,390 --> 00:04:39,180
and then I can go the next 75 to 80 meters

129
00:04:39,180 --> 00:04:41,520
to make the total 150 meters.

130
00:04:41,520 --> 00:04:44,220
By using this repeater, there's going to be no signal loss

131
00:04:44,220 --> 00:04:47,250
because we essentially re-broadcast out a new signal again

132
00:04:47,250 --> 00:04:50,760
from that repeater as we start over our distance limitation.

133
00:04:50,760 --> 00:04:52,410
If you're dealing with fiber cables instead

134
00:04:52,410 --> 00:04:55,110
of copper cables, you have a lot of the same issues in terms

135
00:04:55,110 --> 00:04:57,210
of attenuation because of distance,

136
00:04:57,210 --> 00:05:00,480
but they don't begin to occur until much further out.

137
00:05:00,480 --> 00:05:01,920
This is because we're using light

138
00:05:01,920 --> 00:05:03,600
instead of electricity here.

139
00:05:03,600 --> 00:05:06,390
Now, for example, let's say you have a single mode fiber

140
00:05:06,390 --> 00:05:09,000
that is a maximum distance of 40 kilometers.

141
00:05:09,000 --> 00:05:11,010
You're not going to really suffer much signal loss

142
00:05:11,010 --> 00:05:14,400
until you get around 30 to 40 kilometers from your source,

143
00:05:14,400 --> 00:05:16,470
depending on your environmental conditions.

144
00:05:16,470 --> 00:05:18,960
Another cause of attenuation in fiber cables tends

145
00:05:18,960 --> 00:05:21,300
to occur if you have cheaply constructed fiber cables

146
00:05:21,300 --> 00:05:24,210
or you have fiber cables that have dirty connectors.

147
00:05:24,210 --> 00:05:26,070
Let's imagine you have a pair of sunglasses on

148
00:05:26,070 --> 00:05:28,380
and you have fingerprints all over the lenses.

149
00:05:28,380 --> 00:05:30,360
That makes it really hard to see through 'em, right?

150
00:05:30,360 --> 00:05:32,070
Because you have dirty glasses.

151
00:05:32,070 --> 00:05:34,710
Well, the same thing happens with fiber connectors.

152
00:05:34,710 --> 00:05:36,210
When you're dealing with fiber connections

153
00:05:36,210 --> 00:05:38,550
and your fiber connectors are dirty, this can lead

154
00:05:38,550 --> 00:05:40,260
to signal loss and attenuation

155
00:05:40,260 --> 00:05:41,910
because the light can't cleanly pass

156
00:05:41,910 --> 00:05:44,250
through those connectors because it's dirty.

157
00:05:44,250 --> 00:05:47,070
This adds to attenuation and signal loss for you.

158
00:05:47,070 --> 00:05:48,960
Now, if you're experiencing this attenuation

159
00:05:48,960 --> 00:05:51,630
with fiber cables, the first thing I recommend you do

160
00:05:51,630 --> 00:05:54,720
is change up the fiber cable for a higher quality cable,

161
00:05:54,720 --> 00:05:57,780
or you clean and polish both ends of that fiber

162
00:05:57,780 --> 00:06:00,120
and make sure those connectors are really clean.

163
00:06:00,120 --> 00:06:02,250
You want to make sure there is not a dirty connector there

164
00:06:02,250 --> 00:06:03,510
'cause even something as little

165
00:06:03,510 --> 00:06:04,950
as your fingerprints on it

166
00:06:04,950 --> 00:06:07,500
can cause this attenuation to occur.

167
00:06:07,500 --> 00:06:09,210
Next, we have interference.

168
00:06:09,210 --> 00:06:11,400
Interference occurs when multiple cables operate

169
00:06:11,400 --> 00:06:13,560
in the same frequency band and they operate

170
00:06:13,560 --> 00:06:15,480
in close proximity to each other.

171
00:06:15,480 --> 00:06:16,350
To help prevent this,

172
00:06:16,350 --> 00:06:18,690
we want to use high quality twisted pair cables

173
00:06:18,690 --> 00:06:21,060
or use higher category rated cables.

174
00:06:21,060 --> 00:06:23,400
Now, this is because higher category rated cables

175
00:06:23,400 --> 00:06:25,200
are going to have more internal twists per inch

176
00:06:25,200 --> 00:06:27,180
inside their internal twisted pairs.

177
00:06:27,180 --> 00:06:29,640
These internal twists can help overcome the interference

178
00:06:29,640 --> 00:06:32,070
that can occur within a single cable inside

179
00:06:32,070 --> 00:06:33,930
of its own wired twisted pairs.

180
00:06:33,930 --> 00:06:36,720
Now additionally, if you see a twisted pair network cable

181
00:06:36,720 --> 00:06:37,740
that's being run over

182
00:06:37,740 --> 00:06:40,800
or near a high power cable, this can cause interference

183
00:06:40,800 --> 00:06:43,380
as well and a large amount of signal loss.

184
00:06:43,380 --> 00:06:44,520
To solve this problem,

185
00:06:44,520 --> 00:06:47,370
you always want to plan your cable runs to operate in parallel

186
00:06:47,370 --> 00:06:50,400
and not directly next to any high power cables running

187
00:06:50,400 --> 00:06:52,740
in your cable trays or your risers.

188
00:06:52,740 --> 00:06:55,590
Finally, we have decibel or dB loss.

189
00:06:55,590 --> 00:06:57,720
Now, decibel loss is used to measure the amount

190
00:06:57,720 --> 00:06:59,010
of signal deterioration

191
00:06:59,010 --> 00:07:01,440
that we're experiencing on a given connection.

192
00:07:01,440 --> 00:07:03,450
This can be used to measure the signal on a copper

193
00:07:03,450 --> 00:07:04,860
or fiber cable.

194
00:07:04,860 --> 00:07:05,850
For copper cables,

195
00:07:05,850 --> 00:07:08,970
we see this reported as a dB loss to represent the amount

196
00:07:08,970 --> 00:07:10,320
of voltage that is decreased

197
00:07:10,320 --> 00:07:12,090
since we sent the signal out originally

198
00:07:12,090 --> 00:07:13,740
over that twisted pair cable.

199
00:07:13,740 --> 00:07:15,090
For fiber connections though,

200
00:07:15,090 --> 00:07:17,490
this dB loss is instead going to represent the amount

201
00:07:17,490 --> 00:07:18,600
of light that's lost

202
00:07:18,600 --> 00:07:21,540
as it travels across the cable or the connection.

203
00:07:21,540 --> 00:07:22,980
If you're experiencing a high amount

204
00:07:22,980 --> 00:07:26,010
of dB loss on a copper cable, you need to replace that cable

205
00:07:26,010 --> 00:07:27,930
with a higher quality twisted pair cable

206
00:07:27,930 --> 00:07:29,130
with additional shielding

207
00:07:29,130 --> 00:07:31,170
or a higher number of twists per inch.

208
00:07:31,170 --> 00:07:32,550
If you're experiencing a high amount

209
00:07:32,550 --> 00:07:35,820
of dB loss on a fiber cable, you want to replace that cable

210
00:07:35,820 --> 00:07:37,800
with a higher quality fiber cable, such

211
00:07:37,800 --> 00:07:39,990
as a glass one instead of a plastic one.

212
00:07:39,990 --> 00:07:42,960
Or you need to clean and polish both ends of your cable

213
00:07:42,960 --> 00:07:44,760
and the associated connectors.

214
00:07:44,760 --> 00:07:46,170
Alright, we just covered

215
00:07:46,170 --> 00:07:48,150
our three big cable signaling issues

216
00:07:48,150 --> 00:07:49,770
that you are going to experience in the field

217
00:07:49,770 --> 00:07:51,210
as a network technician.

218
00:07:51,210 --> 00:07:53,340
Just a reminder, these are attenuation,

219
00:07:53,340 --> 00:07:55,380
interference, and decibel loss.

220
00:07:55,380 --> 00:07:58,050
When you're testing your network for attenuation conditions,

221
00:07:58,050 --> 00:07:59,520
always use a cable certifier

222
00:07:59,520 --> 00:08:01,410
to measure the amount of attenuation.

223
00:08:01,410 --> 00:08:04,170
For fiber connections, you're going to use a fiber light meter

224
00:08:04,170 --> 00:08:06,210
to test for attenuation as well.

225
00:08:06,210 --> 00:08:08,550
If you need a test a connection for interference,

226
00:08:08,550 --> 00:08:11,040
you can connect a spectrum analyzer to the cable

227
00:08:11,040 --> 00:08:12,390
to see the exact frequencies

228
00:08:12,390 --> 00:08:14,940
and signals that are being sent over that connection.

229
00:08:14,940 --> 00:08:16,800
If you want to test for decibel loss,

230
00:08:16,800 --> 00:08:19,410
you're going to use a cable certifier, a cable analyzer,

231
00:08:19,410 --> 00:08:21,990
or a fiber light meter to measure the signal being sent

232
00:08:21,990 --> 00:08:23,820
and received across a given cable

233
00:08:23,820 --> 00:08:26,280
and report back that loss in decibels.

234
00:08:26,280 --> 00:08:27,120
For the exam,

235
00:08:27,120 --> 00:08:29,130
it's important to understand the tool you might use

236
00:08:29,130 --> 00:08:31,930
to troubleshoot the different cable connectivity issues.

