1
00:00:00,210 --> 00:00:01,350
Now in this lesson,

2
00:00:01,350 --> 00:00:03,750
we're going to discuss the various copper cable issues

3
00:00:03,750 --> 00:00:05,010
that you may experience.

4
00:00:05,010 --> 00:00:07,110
This includes things like incorrect pinouts,

5
00:00:07,110 --> 00:00:09,630
bad ports, opens, and shorts.

6
00:00:09,630 --> 00:00:11,700
First, we have incorrect pinouts.

7
00:00:11,700 --> 00:00:13,740
If you're testing a twisted pair network connection

8
00:00:13,740 --> 00:00:15,330
and it isn't working properly,

9
00:00:15,330 --> 00:00:17,340
the chances are your connections pinout

10
00:00:17,340 --> 00:00:18,720
is probably incorrect.

11
00:00:18,720 --> 00:00:20,670
Now, there are a few places the connections pinout

12
00:00:20,670 --> 00:00:23,100
could be incorrect, including the patch panel,

13
00:00:23,100 --> 00:00:26,520
the wall jack, or the RJ45 connector itself.

14
00:00:26,520 --> 00:00:27,930
When you look at the patch panel,

15
00:00:27,930 --> 00:00:30,420
there's usually going to be a sticker near the punch down block

16
00:00:30,420 --> 00:00:32,130
that shows you what wire or pin

17
00:00:32,130 --> 00:00:33,990
should be attached to each connection point

18
00:00:33,990 --> 00:00:35,400
on that patch panel.

19
00:00:35,400 --> 00:00:40,380
By default, most patch panels use a TIA-568-B pinout.

20
00:00:40,380 --> 00:00:43,440
This means we have pins one through eight being connected

21
00:00:43,440 --> 00:00:47,610
as white/orange, orange, white/green, blue,

22
00:00:47,610 --> 00:00:51,570
white/blue, green, white/brown and brown.

23
00:00:51,570 --> 00:00:53,220
If you're having an issue with the connection

24
00:00:53,220 --> 00:00:55,200
and you suspect the pinout is incorrect,

25
00:00:55,200 --> 00:00:57,900
you need to visually inspect the back of the patch panel

26
00:00:57,900 --> 00:01:00,330
and its punch down block to ensure the proper colors

27
00:01:00,330 --> 00:01:02,400
are being put in the proper pins.

28
00:01:02,400 --> 00:01:04,319
Now, when you're looking at the back of a wall jack,

29
00:01:04,319 --> 00:01:06,480
the exact same thing holds true.

30
00:01:06,480 --> 00:01:08,340
Instead of being shown as pins one through eight

31
00:01:08,340 --> 00:01:11,070
in a horizontal layout like you might see in a patch panel,

32
00:01:11,070 --> 00:01:13,260
most wall jacks will usually have four pins

33
00:01:13,260 --> 00:01:16,080
on one end of the jack and four pins on the other.

34
00:01:16,080 --> 00:01:18,630
This wall jack is also known as a keystone,

35
00:01:18,630 --> 00:01:21,330
and it's clearly going to be labeled as pins one through eight

36
00:01:21,330 --> 00:01:23,430
or visually using color-coded stickers

37
00:01:23,430 --> 00:01:25,980
or markers for each pin's location.

38
00:01:25,980 --> 00:01:28,980
Finally, we have our RJ45 connector itself.

39
00:01:28,980 --> 00:01:31,530
These plastic connectors are used to connect copper pins

40
00:01:31,530 --> 00:01:35,910
to the inner twisted pair wires of a UTP or STP cable.

41
00:01:35,910 --> 00:01:39,630
While an RJ45 is not clearly labeled from pin one to eight,

42
00:01:39,630 --> 00:01:42,900
or with the TIA-568-B color scheme you need,

43
00:01:42,900 --> 00:01:44,700
you can always visually look at the pins

44
00:01:44,700 --> 00:01:48,030
and see all eight pins inside the RJ45 connector.

45
00:01:48,030 --> 00:01:49,890
When you hold up the RJ45 connector

46
00:01:49,890 --> 00:01:52,410
with a small plastic clip facing downward,

47
00:01:52,410 --> 00:01:54,420
you can then look at the pins and count them

48
00:01:54,420 --> 00:01:57,180
from left to right number from one to eight.

49
00:01:57,180 --> 00:02:00,030
Again, this will ensure that your inner twisted pair wires

50
00:02:00,030 --> 00:02:03,150
are color coded correctly as white/orange, orange,

51
00:02:03,150 --> 00:02:07,680
white/green, blue, white/blue, green, white/brown, brown

52
00:02:07,680 --> 00:02:10,050
when you view it from pin one to pin eight.

53
00:02:10,050 --> 00:02:13,020
To test the connection or a cable and verify its pinout,

54
00:02:13,020 --> 00:02:16,440
you can also use a cable tester or a wire mapping tool.

55
00:02:16,440 --> 00:02:18,030
These tools will test the inner wire

56
00:02:18,030 --> 00:02:19,470
from your cable or connection

57
00:02:19,470 --> 00:02:20,940
and ensure they're properly cabled

58
00:02:20,940 --> 00:02:22,740
from one end to the other.

59
00:02:22,740 --> 00:02:25,350
If the connection is found to be incorrectly pinned out,

60
00:02:25,350 --> 00:02:27,720
you can simply disconnect the individual wires,

61
00:02:27,720 --> 00:02:30,330
restrip the twisted pair cable using a wire stripper

62
00:02:30,330 --> 00:02:32,550
and re-punch down the wires into the patch panel

63
00:02:32,550 --> 00:02:36,750
or wall jack, or replace the RJ45 connector on the cable

64
00:02:36,750 --> 00:02:37,770
until all portions

65
00:02:37,770 --> 00:02:42,240
are properly using the TIA-568-B wiring standards.

66
00:02:42,240 --> 00:02:45,780
Next, we have the issue of bad ports in a copper network.

67
00:02:45,780 --> 00:02:48,540
Each network interface card on a workstation or server

68
00:02:48,540 --> 00:02:51,210
needs to connect to an ethernet twisted pair network

69
00:02:51,210 --> 00:02:52,830
is going to have an ethernet port

70
00:02:52,830 --> 00:02:56,160
that it's going to use and accept an RJ45 connector into.

71
00:02:56,160 --> 00:02:57,450
If you need to test the ethernet

72
00:02:57,450 --> 00:02:59,400
port on your network interface card,

73
00:02:59,400 --> 00:03:01,230
you're going to need to use a loop back plug

74
00:03:01,230 --> 00:03:02,880
and specialized software.

75
00:03:02,880 --> 00:03:04,230
This will let you send out data

76
00:03:04,230 --> 00:03:06,420
and have it returned back in the ethernet port

77
00:03:06,420 --> 00:03:08,790
and determine if everything's functioning properly.

78
00:03:08,790 --> 00:03:11,970
If it isn't, you need to replace the network interface card.

79
00:03:11,970 --> 00:03:13,260
If the network interface card

80
00:03:13,260 --> 00:03:14,880
is soldered to your motherboard,

81
00:03:14,880 --> 00:03:17,130
you can then add an expansion card instead

82
00:03:17,130 --> 00:03:19,950
to replace this broken onboard ethernet port.

83
00:03:19,950 --> 00:03:22,980
Now, if you suspect a bad port on a switch or a router,

84
00:03:22,980 --> 00:03:24,570
you need to connect a loop back plug

85
00:03:24,570 --> 00:03:25,950
to the port on that device

86
00:03:25,950 --> 00:03:28,050
and run a test using specialized software

87
00:03:28,050 --> 00:03:30,090
just like you would on a workstation.

88
00:03:30,090 --> 00:03:32,460
Now, if the port is found to be faulty or bad,

89
00:03:32,460 --> 00:03:34,740
you can then switch out any connections from that port

90
00:03:34,740 --> 00:03:37,320
to another available port on the switcher router.

91
00:03:37,320 --> 00:03:38,550
In the case of a router,

92
00:03:38,550 --> 00:03:40,770
you may also be able to replace the ethernet port

93
00:03:40,770 --> 00:03:42,360
by changing out the interface card

94
00:03:42,360 --> 00:03:44,370
for the router on that slot.

95
00:03:44,370 --> 00:03:46,170
If not, you're going to have to simply move

96
00:03:46,170 --> 00:03:48,600
that connection to another available port.

97
00:03:48,600 --> 00:03:50,940
Finally, we have opens and shorts.

98
00:03:50,940 --> 00:03:53,610
When you conduct a cable test of a twisted pair connection,

99
00:03:53,610 --> 00:03:55,650
you may find an open or a short exists

100
00:03:55,650 --> 00:03:57,480
on that cable connection.

101
00:03:57,480 --> 00:04:00,330
The result of open is going to occur during a cable test

102
00:04:00,330 --> 00:04:02,880
if you have nothing on the other end of the connection,

103
00:04:02,880 --> 00:04:05,100
or if there's some kind of a break in the wires

104
00:04:05,100 --> 00:04:07,200
between the source and the destination.

105
00:04:07,200 --> 00:04:10,290
So if I'm conducting a test of a cable from a patch panel

106
00:04:10,290 --> 00:04:13,290
to the wall jack over a patch cable into my tester

107
00:04:13,290 --> 00:04:15,630
and reports is open, that means somewhere

108
00:04:15,630 --> 00:04:17,130
in that end-to-end connection.

109
00:04:17,130 --> 00:04:18,240
It's either disconnected

110
00:04:18,240 --> 00:04:21,480
or one of those cables has been accidentally cut or broken.

111
00:04:21,480 --> 00:04:22,350
At that point,

112
00:04:22,350 --> 00:04:24,510
we're going to need to test each piece of the connection

113
00:04:24,510 --> 00:04:26,460
to determine where that brake exists.

114
00:04:26,460 --> 00:04:29,100
For example, I might first test the patch cable,

115
00:04:29,100 --> 00:04:30,270
and if that's successful,

116
00:04:30,270 --> 00:04:32,340
I know that the problem isn't my patch cable,

117
00:04:32,340 --> 00:04:34,620
and instead I'm going to look at the patch panel connection

118
00:04:34,620 --> 00:04:36,420
or the wall jack connection.

119
00:04:36,420 --> 00:04:39,120
The opposite of an open is considered a short.

120
00:04:39,120 --> 00:04:42,000
Now, a short indicates that two wires are connected together

121
00:04:42,000 --> 00:04:43,650
somewhere in that connection.

122
00:04:43,650 --> 00:04:46,290
Usually this occurs when a cable is poorly made

123
00:04:46,290 --> 00:04:48,420
or two of the inner twisted pair wires

124
00:04:48,420 --> 00:04:49,860
accidentally touching each other

125
00:04:49,860 --> 00:04:52,380
in a single pin of an RJ45 connector.

126
00:04:52,380 --> 00:04:54,270
If you're experiencing a shorten your connection,

127
00:04:54,270 --> 00:04:56,550
you should rewire the RJ45 connection

128
00:04:56,550 --> 00:04:57,540
at the end of the cable,

129
00:04:57,540 --> 00:04:59,910
as this is usually going to be the source of your problem.

130
00:04:59,910 --> 00:05:01,140
If this doesn't fix it,

131
00:05:01,140 --> 00:05:03,510
then you need to physically examine the entire cable

132
00:05:03,510 --> 00:05:04,380
to see if it's been damaged

133
00:05:04,380 --> 00:05:06,450
somewhere in the middle of that cable run.

134
00:05:06,450 --> 00:05:08,640
Alternatively, you can simply replace the cable

135
00:05:08,640 --> 00:05:11,640
with a known good cable, and this can also solve your issue.

136
00:05:11,640 --> 00:05:13,650
If you need a test for incorrect pin outs,

137
00:05:13,650 --> 00:05:17,100
opens and shorts a good cable tester, a cable certifier,

138
00:05:17,100 --> 00:05:20,520
or a wire mapping tool will be the key to your success.

139
00:05:20,520 --> 00:05:22,200
If you're testing for a bad port,

140
00:05:22,200 --> 00:05:24,480
then a loop back adapter or a loop back plug

141
00:05:24,480 --> 00:05:26,070
is going to be the tool to use.

142
00:05:26,070 --> 00:05:27,540
Remember, for the exam,

143
00:05:27,540 --> 00:05:28,560
it's important to understand

144
00:05:28,560 --> 00:05:30,120
which tool you might need to use

145
00:05:30,120 --> 00:05:32,720
to troubleshoot different cable connectivity issues.
