1
00:00:00,210 --> 00:00:01,043
In this lesson,

2
00:00:01,043 --> 00:00:03,870
we're going to discuss Power over Ethernet issues.

3
00:00:03,870 --> 00:00:05,790
Power over Ethernet is a technology

4
00:00:05,790 --> 00:00:08,400
that allows network cables to carry both electrical power

5
00:00:08,400 --> 00:00:10,650
and data over a single line.

6
00:00:10,650 --> 00:00:12,330
Power over Ethernet is really useful

7
00:00:12,330 --> 00:00:14,880
for devices like IP cameras, VoIP phones,

8
00:00:14,880 --> 00:00:16,470
and Wi-Fi access points

9
00:00:16,470 --> 00:00:18,180
because it enables them to receive power

10
00:00:18,180 --> 00:00:20,760
and data through the same copper network cable.

11
00:00:20,760 --> 00:00:23,430
By using a single cable for both data and power,

12
00:00:23,430 --> 00:00:24,870
we can simplify our cabling

13
00:00:24,870 --> 00:00:26,910
and reduce the need for additional power sources

14
00:00:26,910 --> 00:00:28,800
for our endpoint devices.

15
00:00:28,800 --> 00:00:31,140
Now, Power over Ethernet comes in two varieties,

16
00:00:31,140 --> 00:00:33,450
known as Power over Ethernet, or PoE,

17
00:00:33,450 --> 00:00:36,630
and Power over Ethernet Plus, or PoE+.

18
00:00:36,630 --> 00:00:39,000
PoE and PoE+ are actually governed

19
00:00:39,000 --> 00:00:41,310
by different IEEE standards though.

20
00:00:41,310 --> 00:00:43,320
Power over Ethernet, or PoE,

21
00:00:43,320 --> 00:00:47,430
is defined by the IEEE 802.3af standard.

22
00:00:47,430 --> 00:00:49,500
Now, this PoE standard was the first one

23
00:00:49,500 --> 00:00:50,730
to be widely adopted,

24
00:00:50,730 --> 00:00:53,550
and it has the ability to provide up to 15.4 watts

25
00:00:53,550 --> 00:00:56,520
of DC power to each of your endpoint devices.

26
00:00:56,520 --> 00:00:58,950
With PoE though, there's actually some power loss

27
00:00:58,950 --> 00:01:00,270
that occurs as the power moves

28
00:01:00,270 --> 00:01:01,920
from the Power over Ethernet switch

29
00:01:01,920 --> 00:01:03,690
across the copper network cabling

30
00:01:03,690 --> 00:01:05,400
and over to the endpoint device.

31
00:01:05,400 --> 00:01:07,620
So the actual minimum guaranteed power available

32
00:01:07,620 --> 00:01:10,860
to your endpoint device is only going to be 12.95 watts

33
00:01:10,860 --> 00:01:12,840
of DC power instead.

34
00:01:12,840 --> 00:01:15,780
Now, Power over Ethernet Plus, or PoE+,

35
00:01:15,780 --> 00:01:19,860
is defined by the IEEE 802.3at standard.

36
00:01:19,860 --> 00:01:22,980
This PoE+ standard was developed as an enhanced version

37
00:01:22,980 --> 00:01:25,590
of the older Power over Ethernet standard.

38
00:01:25,590 --> 00:01:27,120
Now, one of the biggest changes from PoE

39
00:01:27,120 --> 00:01:29,640
to PoE+ was the increasing the amount

40
00:01:29,640 --> 00:01:31,830
of power available for your endpoint devices

41
00:01:31,830 --> 00:01:35,670
because PoE+ can now provide up to 30 watts of DC power

42
00:01:35,670 --> 00:01:37,710
to each of your endpoint devices.

43
00:01:37,710 --> 00:01:39,930
Similar to PoE though, there is power loss

44
00:01:39,930 --> 00:01:41,610
that occurs over the network cable,

45
00:01:41,610 --> 00:01:43,710
so the actual minimum guaranteed power available

46
00:01:43,710 --> 00:01:44,910
at the endpoint device

47
00:01:44,910 --> 00:01:48,630
is only going to be 25.5 watts of DC power.

48
00:01:48,630 --> 00:01:51,100
Now, despite the advantages of using something like PoE

49
00:01:51,100 --> 00:01:53,250
and PoE+, there are some issues

50
00:01:53,250 --> 00:01:55,380
that arise when you implement Power over Ethernet

51
00:01:55,380 --> 00:01:56,910
in your enterprise networks,

52
00:01:56,910 --> 00:01:58,530
including things like errors associated

53
00:01:58,530 --> 00:02:00,210
with the power budget being exceeded

54
00:02:00,210 --> 00:02:02,520
and the incorrect standard being selected.

55
00:02:02,520 --> 00:02:05,610
Now, first, we have the power budget exceeded error.

56
00:02:05,610 --> 00:02:08,340
The power budget exceeded error occurs when the power demand

57
00:02:08,340 --> 00:02:10,050
from the connected endpoint device

58
00:02:10,050 --> 00:02:11,880
exceeds the power supply capacity

59
00:02:11,880 --> 00:02:13,530
of the Power over Ethernet switch

60
00:02:13,530 --> 00:02:15,390
or power ejection device.

61
00:02:15,390 --> 00:02:17,940
Each PoE switch or injector is going to be designed

62
00:02:17,940 --> 00:02:20,550
with a maximum power capacity that it can deliver.

63
00:02:20,550 --> 00:02:23,280
This capacity is known as the power budget.

64
00:02:23,280 --> 00:02:25,110
Now, this power budget is the sum of all

65
00:02:25,110 --> 00:02:26,700
of the DC power available to all

66
00:02:26,700 --> 00:02:29,130
of your endpoint devices connected to that switch,

67
00:02:29,130 --> 00:02:30,600
not just the amount of power available

68
00:02:30,600 --> 00:02:32,280
on a single switch port.

69
00:02:32,280 --> 00:02:34,350
Now, whenever the cumulative power requirement for all

70
00:02:34,350 --> 00:02:36,690
of your connected endpoint devices gets exceeded,

71
00:02:36,690 --> 00:02:38,490
your network is going to start to have issues

72
00:02:38,490 --> 00:02:40,980
with your PoE-supported endpoint devices.

73
00:02:40,980 --> 00:02:43,530
For example, those devices may randomly begin

74
00:02:43,530 --> 00:02:46,650
to restart themselves, or they may refuse to power on,

75
00:02:46,650 --> 00:02:49,680
or they may behave erratically in some way.

76
00:02:49,680 --> 00:02:52,020
To resolve the power budget exceeded error,

77
00:02:52,020 --> 00:02:53,940
you should first check the power requirements for each

78
00:02:53,940 --> 00:02:55,860
of your connected endpoint devices.

79
00:02:55,860 --> 00:02:57,870
Then you need to add up the power requirements

80
00:02:57,870 --> 00:03:00,660
for all of those connected devices and compare that value

81
00:03:00,660 --> 00:03:02,400
with the total power budget available

82
00:03:02,400 --> 00:03:04,260
for your Power over Ethernet source,

83
00:03:04,260 --> 00:03:06,750
such as your PoE-enabled network switch.

84
00:03:06,750 --> 00:03:08,430
Then, if the total you calculate

85
00:03:08,430 --> 00:03:10,650
exceeds your available power budget, you need

86
00:03:10,650 --> 00:03:13,200
to start considering removing some non-essential devices

87
00:03:13,200 --> 00:03:15,000
to reduce the required power levels,

88
00:03:15,000 --> 00:03:17,250
or you need to upgrade your PoE source,

89
00:03:17,250 --> 00:03:18,570
like your network switch to one

90
00:03:18,570 --> 00:03:20,940
that has a higher overall power budget.

91
00:03:20,940 --> 00:03:23,640
Second, we have an incorrect standard error.

92
00:03:23,640 --> 00:03:24,960
As discussed earlier,

93
00:03:24,960 --> 00:03:27,060
Power over Ethernet comes in two varieties

94
00:03:27,060 --> 00:03:31,050
that rely on the two different standards of PoE and PoE+.

95
00:03:31,050 --> 00:03:33,360
If you're trying to run a PoE+ endpoint device

96
00:03:33,360 --> 00:03:35,340
that's expecting to receive a maximum of 30 watts

97
00:03:35,340 --> 00:03:38,700
of DC power, but you're connecting it to an older PoE switch

98
00:03:38,700 --> 00:03:41,850
that only can provide 15.4 watts of DC power,

99
00:03:41,850 --> 00:03:44,370
this will start to cause issues for that endpoint device

100
00:03:44,370 --> 00:03:46,560
and it will fail to work properly.

101
00:03:46,560 --> 00:03:49,140
Now, if you have a mismatch between the PoE device standard

102
00:03:49,140 --> 00:03:51,090
that you need to use and the PoE standard

103
00:03:51,090 --> 00:03:53,220
that your PoE enabled switch can provide,

104
00:03:53,220 --> 00:03:54,090
this will also lead

105
00:03:54,090 --> 00:03:56,370
to an incorrect standard error occurring.

106
00:03:56,370 --> 00:03:58,290
To resolve an incorrect standard error,

107
00:03:58,290 --> 00:03:59,940
you should first check the PoE standard

108
00:03:59,940 --> 00:04:01,950
that's being supported by both the endpoint device

109
00:04:01,950 --> 00:04:03,780
and the PoE-enabled switch.

110
00:04:03,780 --> 00:04:05,880
Then you should ensure there is compatibility

111
00:04:05,880 --> 00:04:07,650
between those two devices.

112
00:04:07,650 --> 00:04:09,780
For example, I've used some endpoint devices

113
00:04:09,780 --> 00:04:12,420
like VoIP phones that can be powered by either a PoE

114
00:04:12,420 --> 00:04:14,970
or PoE+ enabled network device.

115
00:04:14,970 --> 00:04:17,100
In this case, the VoIP phone could be configured

116
00:04:17,100 --> 00:04:19,019
to use either of those two standards,

117
00:04:19,019 --> 00:04:21,240
but I've also used some video-based phone

118
00:04:21,240 --> 00:04:22,680
that will only support receiving power

119
00:04:22,680 --> 00:04:24,990
from a PoE+ enabled network device

120
00:04:24,990 --> 00:04:27,570
because those endpoint devices require the maximum

121
00:04:27,570 --> 00:04:29,640
of 30 watts of DC power to be able

122
00:04:29,640 --> 00:04:31,920
to power on and operate efficiently.

123
00:04:31,920 --> 00:04:34,590
If you connected one of these PoE+ only client devices

124
00:04:34,590 --> 00:04:36,270
to a regular PoE switch,

125
00:04:36,270 --> 00:04:38,100
the device will either not function properly,

126
00:04:38,100 --> 00:04:39,990
or it simply won't power up

127
00:04:39,990 --> 00:04:41,880
because you're using that older PoE connection

128
00:04:41,880 --> 00:04:44,070
and it's not providing enough power.

129
00:04:44,070 --> 00:04:45,240
Now, if you have a mismatch

130
00:04:45,240 --> 00:04:46,073
where your network switch

131
00:04:46,073 --> 00:04:48,360
can't support the newer PoE+ standard,

132
00:04:48,360 --> 00:04:49,680
you can either replace that switch

133
00:04:49,680 --> 00:04:52,170
with a newer one that does support PoE+,

134
00:04:52,170 --> 00:04:54,900
or you can use Power over Ethernet injectors

135
00:04:54,900 --> 00:04:57,870
that match the PoE+ standard to provide more power

136
00:04:57,870 --> 00:04:59,700
to your endpoint devices.

137
00:04:59,700 --> 00:05:01,530
Now, a Power over Ethernet injector,

138
00:05:01,530 --> 00:05:04,320
also known as a PoE injector, is simply a device

139
00:05:04,320 --> 00:05:05,520
that adds electrical power

140
00:05:05,520 --> 00:05:07,470
to a standard Ethernet data cable,

141
00:05:07,470 --> 00:05:08,850
so you can provide both power

142
00:05:08,850 --> 00:05:12,060
and data to a PoE-capable endpoint device.

143
00:05:12,060 --> 00:05:14,610
So remember, Power over Ethernet is a technology

144
00:05:14,610 --> 00:05:16,920
that allows network cables to carry both data

145
00:05:16,920 --> 00:05:19,380
and electrical power at the same time.

146
00:05:19,380 --> 00:05:21,150
Power over Ethernet issues can occur

147
00:05:21,150 --> 00:05:22,980
when either the power budget is exceeded

148
00:05:22,980 --> 00:05:24,990
or the incorrect standard is being used

149
00:05:24,990 --> 00:05:26,370
between the endpoint devices

150
00:05:26,370 --> 00:05:28,830
and the network devices that are providing the power.

151
00:05:28,830 --> 00:05:31,530
When a Power over Ethernet issue occurs, you can expect

152
00:05:31,530 --> 00:05:32,430
that your endpoint device

153
00:05:32,430 --> 00:05:34,290
will either restart itself randomly,

154
00:05:34,290 --> 00:05:35,730
won't work properly at all,

155
00:05:35,730 --> 00:05:39,030
or it'll simply not power on when you try to boot it up.

156
00:05:39,030 --> 00:05:40,290
Therefore, it's important for you

157
00:05:40,290 --> 00:05:42,510
to understand the symptoms, potential causes,

158
00:05:42,510 --> 00:05:44,250
and the troubleshooting methodologies that are used

159
00:05:44,250 --> 00:05:47,010
to identify and resolve these Power over Ethernet issues

160
00:05:47,010 --> 00:05:48,010
within your network.
