﻿1
00:00:00,133 --> 00:00:01,100
Hello and welcome back.

2
00:00:01,100 --> 00:00:05,333
Today we're talking about the confusion
matrix and different accuracy ratios.

3
00:00:05,866 --> 00:00:09,300
So let's imagine
that we are building a model

4
00:00:09,300 --> 00:00:14,200
that will predict based on images
X-ray images of lungs

5
00:00:14,200 --> 00:00:17,200
whether there is cancer
or not in the lungs.

6
00:00:17,466 --> 00:00:20,100
So we're going to build a matrix
here on the left.

7
00:00:20,100 --> 00:00:22,600
On the top
we have the prediction of our model.

8
00:00:22,600 --> 00:00:25,500
And it can be negative
no cancer or positive.

9
00:00:25,500 --> 00:00:26,900
Yeah there is cancer.

10
00:00:26,900 --> 00:00:32,100
And then on the left we have
the actual state of things is there.

11
00:00:32,333 --> 00:00:33,900
is it negative?

12
00:00:33,900 --> 00:00:36,866
There is no cancer and in reality
there is no cancer.

13
00:00:36,866 --> 00:00:40,666
that person doesn't
have cancer or positive.

14
00:00:40,666 --> 00:00:42,900
That person does have cancer.

15
00:00:42,900 --> 00:00:47,800
So and once we cross these rows and
columns will have four different cells.

16
00:00:47,833 --> 00:00:50,833
The top left
one is called the true negative.

17
00:00:51,466 --> 00:00:54,133
and by the way, before we go into this,

18
00:00:54,133 --> 00:00:58,066
the positioning of these cells
depends on the source.

19
00:00:58,066 --> 00:00:59,833
Yet you are looking at some,

20
00:00:59,833 --> 00:01:04,266
places draw confusion
matrix one way, other places other way.

21
00:01:04,266 --> 00:01:08,933
So and I'll link to a, an article
about this at the end of this tutorial.

22
00:01:09,400 --> 00:01:11,666
So back to back to our true negative.

23
00:01:11,666 --> 00:01:15,400
So the cross between negative
and negative is a true negative

24
00:01:15,400 --> 00:01:18,400
meaning the model predicted
that there is no cancer.

25
00:01:18,600 --> 00:01:21,133
And in reality
that person doesn't have cancer.

26
00:01:21,133 --> 00:01:26,400
So in this use case, it's a great result,
for the person that, in question.

27
00:01:27,066 --> 00:01:29,300
Now the bottom right is called
the true positive.

28
00:01:29,300 --> 00:01:31,833
The model predicted
that this person has cancer.

29
00:01:31,833 --> 00:01:34,500
And in reality, they also have cancer.

30
00:01:34,500 --> 00:01:35,833
And while this is not

31
00:01:35,833 --> 00:01:39,366
a great result at all
for the person in question, in this model,

32
00:01:39,866 --> 00:01:46,066
at least they know that they have cancer
and they can now address it

33
00:01:46,066 --> 00:01:49,066
with their a doctor and potentially

34
00:01:49,066 --> 00:01:52,066
hopefully get better, get treatment.

35
00:01:52,200 --> 00:01:57,200
Now in the top right we have something
that's called a false positive.

36
00:01:57,700 --> 00:02:00,600
The model predicts
that the person has cancer, but in reality

37
00:02:00,600 --> 00:02:01,833
they don't have cancer.

38
00:02:01,833 --> 00:02:04,233
And this is called a type one error.

39
00:02:04,233 --> 00:02:07,800
And this is a problem
because even though for the person

40
00:02:07,800 --> 00:02:10,800
in question,
it's a relief that they don't have cancer.

41
00:02:10,933 --> 00:02:15,900
Imagine the emotional stress
and suffering that they will go through

42
00:02:15,933 --> 00:02:19,633
when the when they're told by the model
that they have cancer,

43
00:02:19,966 --> 00:02:21,100
even though they don't have to go

44
00:02:21,100 --> 00:02:24,533
through the stress and suffering because
they don't actually have any cancer.

45
00:02:25,200 --> 00:02:28,900
so it would be much better
if the model told them the correct answer.

46
00:02:29,866 --> 00:02:31,933
made the correct
prediction that they don't have cancer.

47
00:02:31,933 --> 00:02:34,933
So it would be much better
if the model gave them a true negative.

48
00:02:35,366 --> 00:02:39,266
And then in the bottom left
we have a false negative, which is a type

49
00:02:39,266 --> 00:02:43,666
two error where the person actually does
have cancer in in reality.

50
00:02:43,666 --> 00:02:45,233
But the model says they don't.

51
00:02:45,233 --> 00:02:50,166
And this is a very dangerous type of error
because, in this use case,

52
00:02:50,600 --> 00:02:55,400
the doctors won't even treat the person
won't even recommend any treatment plan

53
00:02:55,400 --> 00:02:56,300
because they'll think

54
00:02:56,300 --> 00:02:59,566
that the person doesn't have cancer
and the cancer can grow and get worse.

55
00:03:00,033 --> 00:03:02,500
So both errors are not great.

56
00:03:02,500 --> 00:03:04,233
And we want to avoid them.

57
00:03:04,233 --> 00:03:06,200
So the less errors
our models make, the better.

58
00:03:06,200 --> 00:03:10,200
Now let's populate this matrix
with actual figures.

59
00:03:10,200 --> 00:03:12,700
Let's say we have 100 patients
out of them.

60
00:03:12,700 --> 00:03:17,333
our model made some predictions
and we have 43 true negatives, 41 true

61
00:03:17,333 --> 00:03:18,333
positives.

62
00:03:18,333 --> 00:03:21,900
12 the type one errors or false positives

63
00:03:21,900 --> 00:03:26,033
and four, type
two errors or false negatives.

64
00:03:26,366 --> 00:03:31,666
From this confusion matrix, we can
calculate the following rates or ratios.

65
00:03:31,666 --> 00:03:34,666
We have the accuracy rate
and the error rate.

66
00:03:34,766 --> 00:03:38,433
The accuracy rate is the total number
of correct predictions,

67
00:03:38,900 --> 00:03:41,500
meaning the true negatives
plus the true positives divided

68
00:03:41,500 --> 00:03:45,500
by the total number of patients
in this sample.

69
00:03:45,500 --> 00:03:48,400
So we have 84 divide 100 or 84%.

70
00:03:48,400 --> 00:03:52,666
And the error rate is the total number
of incorrect predictions,

71
00:03:52,800 --> 00:03:55,700
meaning the type
one errors plus the type two errors.

72
00:03:56,700 --> 00:03:57,066
we have

73
00:03:57,066 --> 00:04:00,300
16 of those
divided by the total sample size 100.

74
00:04:00,300 --> 00:04:03,300
So we have 16% error rate here.

75
00:04:03,500 --> 00:04:07,233
So those are two, 
important rates to be able to calculate.

76
00:04:07,933 --> 00:04:10,833
So that's how the confusion 
matrix matrix works.

77
00:04:10,833 --> 00:04:13,900
And as additional reading,
I highly recommend checking out

78
00:04:13,900 --> 00:04:18,733
this article to, have it
handy for future use

79
00:04:19,000 --> 00:04:23,000
where the person investigated, 
the different

80
00:04:23,900 --> 00:04:28,600
forms of confusion
matrix because, different tools, Python

81
00:04:28,600 --> 00:04:32,000
or any other tool
that you might be using can, produce

82
00:04:32,000 --> 00:04:35,733
a different confusion matrix is better,
is good to read through it.

83
00:04:35,733 --> 00:04:39,300
So you always know which confusion matrix
you're dealing with in specific instance

84
00:04:39,633 --> 00:04:40,800
and in the tutorial.

85
00:04:40,800 --> 00:04:44,366
In all practical terms, you'll be dealing
with the one that we discussed today

86
00:04:44,366 --> 00:04:46,433
and the one that's pictured
here on the bottom right.

87
00:04:47,433 --> 00:04:48,733
So I hope you enjoyed this tutorial.

88
00:04:48,733 --> 00:04:51,566
I'll see you next time.
Until then, enjoy machine learning.