1
00:00:00,920 --> 00:00:08,180
Lease lines are an example of synchronous serial communication, where one party provides the clocking

2
00:00:08,180 --> 00:00:09,800
for the communication.

3
00:00:09,800 --> 00:00:15,620
So in other words, two devices will synchronize their clocks before data transmission takes place.

4
00:00:15,620 --> 00:00:23,330
So they will align or synchronize those clocks and agree on parameters for data transfer, including

5
00:00:23,330 --> 00:00:26,090
the data interval between bits of data.

6
00:00:26,920 --> 00:00:34,240
The CSU issue or channel service unit data service unit, commonly referred to as the CSU, provides

7
00:00:34,240 --> 00:00:38,290
the clocking and is the master for the communication.

8
00:00:38,500 --> 00:00:44,410
The rate is acting as a slave and is receiving its clocking from the CSU.

9
00:00:44,770 --> 00:00:52,720
So essentially before communication can start, the two devices have to align their clocks or agree

10
00:00:52,720 --> 00:00:56,950
on the clock intervals to ensure that data doesn't get corrupted.

11
00:00:56,980 --> 00:01:05,080
So here we have the terms data, communication equipment or DCE and data terminal equipment or DTD.

12
00:01:05,440 --> 00:01:12,220
The most in the communication is the CSU DSU and it's using its own internal clocking.

13
00:01:12,370 --> 00:01:19,690
But the rudder, which is the data terminal equipment or dty, uses the external clocking received from

14
00:01:19,690 --> 00:01:25,300
the DCE and will thus synchronize itself to the CSU DSU.

15
00:01:25,690 --> 00:01:35,350
So the CSU DSU is the DCI side of the connection and the router is the dty side of the connection.

16
00:01:35,710 --> 00:01:45,040
So the DCI, which is the CSU DSU is providing clocking to the rudder, which is the DTY, and the DCE

17
00:01:45,040 --> 00:01:54,100
also terminates the connection from the carrier, and a connection is then made from the CSU DSU to

18
00:01:54,100 --> 00:01:54,790
the router.

19
00:01:55,570 --> 00:02:00,820
Some terms to understand, therefore, is customer premises, equipment or CPE.

20
00:02:00,970 --> 00:02:08,470
This is the term that telcos or service providers use to refer to equipment that resides at the customer

21
00:02:08,470 --> 00:02:10,780
site at the end of their connection.

22
00:02:11,350 --> 00:02:16,270
So once again, in this example, the CE issued issue is at the customer's site.

23
00:02:16,630 --> 00:02:23,890
The key issue, DSU, which is the DCC, is connected in this example via a V 35 cable to the router

24
00:02:23,890 --> 00:02:26,440
and is providing clocking to the router.

25
00:02:26,890 --> 00:02:35,740
So the CSU issue, which is the DCC physically controls the speed and timing at which the router serial

26
00:02:35,740 --> 00:02:40,120
interfaces can send and receive bits over the serial cable.

27
00:02:40,360 --> 00:02:49,000
You don't have the ability to configure the speed of your serial connection that is set by the CSU DSU

28
00:02:49,000 --> 00:02:53,080
and is generally set by the service provider on your behalf.

29
00:02:53,380 --> 00:02:57,700
The serial cable once again connects the CSU to the router interface.
