1
00:00:00,700 --> 00:00:08,530
Now here's an SNP message once again from the network management station, in other words, NPM to router

2
00:00:08,530 --> 00:00:10,980
2 10.1.102.

3
00:00:11,470 --> 00:00:13,390
You can see this is an SNP message

4
00:00:14,420 --> 00:00:21,980
and SNMP uses UDP or user datagram protocol, which is a connectionless protocol, unlike TCP.

5
00:00:23,020 --> 00:00:27,280
UDP doesn't provide reliability in the same way that TCP does.

6
00:00:27,970 --> 00:00:31,090
You'll also notice that the port is port 161.

7
00:00:32,080 --> 00:00:38,260
So the network management station is communicating with the router on Destination Port 161 and

8
00:00:38,260 --> 00:00:45,640
the routers replying back from Port 161 to the ephemeral or random port number that was chosen by the

9
00:00:45,640 --> 00:00:46,240
NMS.

10
00:00:46,240 --> 00:00:55,120
For this connection, it's important to remember that UDP Port 161 is the destination port that the

11
00:00:55,120 --> 00:00:57,310
NMS initiates sessions to.

12
00:00:57,850 --> 00:01:06,460
In other words, the NMS or NPM, in this case, is going to be initiating sessions to routers on Port

13
00:01:06,490 --> 00:01:07,480
161.

14
00:01:08,320 --> 00:01:18,010
You need to ensure that your firewalls or access lists or HCLs permit or allow UDP Port 161 from

15
00:01:18,010 --> 00:01:20,500
the NMS to the devices that are being monitored

16
00:01:20,890 --> 00:01:23,520
and the reverse traffic also needs to be permitted.

17
00:01:24,100 --> 00:01:29,760
You may even want to configure devices to use a non-default port for SNMP.

18
00:01:30,250 --> 00:01:37,630
So rather than using the default port of 161, you may choose to use a another port number like 10000

19
00:01:38,050 --> 00:01:39,280
161.

20
00:01:39,970 --> 00:01:46,540
You would configure that on the device and you would also need to configure that on NPM so it knows which

21
00:01:46,540 --> 00:01:47,350
port number

22
00:01:47,350 --> 00:01:56,830
to use to connect to that device for monitoring in both the SNMP get or SNMP request as well as the response,

23
00:01:57,490 --> 00:02:05,700
you'll see the OID values and move information that NPM is getting from the device.

24
00:02:06,400 --> 00:02:12,910
So in the request, we can see that the values are null and in the reply we can see the actual values for

25
00:02:12,910 --> 00:02:13,900
those OIDs.

26
00:02:14,770 --> 00:02:22,030
We'll explore that in more detail in a separate video where we discuss OIDs, MIBS, and other options.

