1
00:00:01,320 --> 00:00:02,330
Hello and welcome.

2
00:00:02,340 --> 00:00:05,710
Now let's talk about how the tests are transformed.

3
00:00:05,850 --> 00:00:14,190
As you can see transformer comes in different shapes but they all follow the very same symbol principle.

4
00:00:14,190 --> 00:00:18,390
Transformers are wires that have resistance.

5
00:00:18,390 --> 00:00:27,090
So no matter how many terminals there is if there is a resistance between each two pins depending on

6
00:00:27,090 --> 00:00:31,950
the type of transformer it means that the transformer is working.

7
00:00:31,950 --> 00:00:40,800
Now depending on how high or low this transistor is you can identify that primary and secondary coils

8
00:00:41,130 --> 00:00:45,390
or you can identify that a coil is burned out.

9
00:00:45,390 --> 00:00:50,360
Now the first step is metal indication for this thing.

10
00:00:50,370 --> 00:00:52,380
A good transformer.

11
00:00:52,380 --> 00:00:53,770
That primary one.

12
00:00:53,790 --> 00:00:57,360
And second that funding can be tested as follows.

13
00:00:57,720 --> 00:01:08,820
You need to set your multimeter to the resistance measuring for the indicator now place the two probes

14
00:01:08,970 --> 00:01:18,330
on these two terminals of the transformer all that run the thermal that you think are the primary terminals.

15
00:01:18,350 --> 00:01:22,940
Now the meter deflection indicating higher resistance.

16
00:01:22,940 --> 00:01:26,700
This means that this is the primary windowing.

17
00:01:26,780 --> 00:01:34,060
Now if the meter deflection indicates low resistance this means that this is the secondary window.

18
00:01:34,070 --> 00:01:41,900
So whenever you are testing to find out what cha the primary would and which are the secondary the ones

19
00:01:41,900 --> 00:01:48,740
with the high resistance are the primary landing and the ones with the low resistance are the secondary

20
00:01:49,360 --> 00:01:50,110
Wendy.

21
00:01:50,120 --> 00:02:01,130
Now if you want to know if the transformer one thing's primary or secondary are shorted or open you

22
00:02:01,130 --> 00:02:10,500
can use the symbol taste of resistance if the meter deflection indicating zero resistance in the meter.

23
00:02:10,550 --> 00:02:18,830
This means that our transformer is shorted Now if no meet up deflection indicating infinite resistance.

24
00:02:18,830 --> 00:02:26,690
So if the resistance went very very high to the maximum at the analog multimeter or the highest or infinite

25
00:02:26,690 --> 00:02:32,820
value in the digital multimeter This means that there is a cut in our transformer windowing.

26
00:02:32,900 --> 00:02:37,850
So how do you know which are the terminals for primary and secondary.

27
00:02:37,850 --> 00:02:46,560
Usually by copying the transformer name or number and finding this number and looking up on Google for

28
00:02:46,560 --> 00:02:55,530
the street or for that specific transformer you can easily identify these numbered terminals and know

29
00:02:55,650 --> 00:03:00,790
which are for the primary and which are for the secondary now.

30
00:03:00,800 --> 00:03:06,470
Next we are going to cover that as a store but for now what I need you to know is that every transformer

31
00:03:06,470 --> 00:03:16,250
has a different type of test but all depends on a very basic truth which is transformer is basically

32
00:03:16,280 --> 00:03:18,260
out that has the resistance.

33
00:03:18,440 --> 00:03:20,750
So the resistance is too high.

34
00:03:20,750 --> 00:03:26,080
This means that this is the primary one thing and if it is too low this means that it is a secondary

35
00:03:26,090 --> 00:03:28,640
one thing if it is zero resistance.

36
00:03:28,640 --> 00:03:36,140
This means that that specific Windowing is shorted if it is infinite resistance or in finite resistance

37
00:03:36,200 --> 00:03:42,260
it means that this lending is often.

38
00:03:42,400 --> 00:03:51,070
So this is the overall usually what I do is look up the transformer online to know the terminals and

39
00:03:51,190 --> 00:03:58,240
label them with numbers or letters then start that this by identifying the primary and the secondary

40
00:03:58,690 --> 00:04:06,610
then move on to test if there is a shorted or open one thing inside that transformer.

41
00:04:06,610 --> 00:04:12,220
I will add more resources on how to test a transformer to this section but that's it for now.

42
00:04:12,220 --> 00:04:13,060
Thanks for watching.

43
00:04:13,060 --> 00:04:15,820
This is Ashraf from educational engineering team.