1
00:00:00,540 --> 00:00:08,310
Measuring voltage voltage type there is two types of voltage which is DC and AC and we did mention the

2
00:00:08,370 --> 00:00:15,300
difference between them earlier when measuring voltage at the meter blobs are placed across the voltage

3
00:00:15,300 --> 00:00:23,910
source the Volt or meter are used to separate functions and ranges to measure DC and AC because AC is

4
00:00:23,910 --> 00:00:29,640
constantly changing with form measuring AC voltage is not a simple matter.

5
00:00:29,640 --> 00:00:37,670
This Volt on meet our emissions base with automatic voltage and we must mention that when measuring

6
00:00:37,670 --> 00:00:44,330
voltage the Volt on meter is used to by the voltage across the source which is different than when measuring

7
00:00:44,330 --> 00:00:50,790
current with the current in the circuit must flow through the Volt or meter to be measured.

8
00:00:50,990 --> 00:00:58,250
This make it far easier to measure voltage and circuit because the operator can simply place the probes

9
00:00:58,280 --> 00:01:05,510
across the component as it is while in the circuit while measuring current that both brutal the operator

10
00:01:05,510 --> 00:01:14,620
must physically interrupt the circuit unsold of and connect and insert the Volt o meter into the circuit.

11
00:01:14,630 --> 00:01:21,470
So you might have to unseal that component of that its connection so that you can measure the current

12
00:01:21,470 --> 00:01:23,720
flowing through it burnt.

13
00:01:23,790 --> 00:01:31,730
We must point out that the two voltage measurement ranges one for DC and other for the C and we will

14
00:01:31,730 --> 00:01:34,530
see how to measure both of these.

15
00:01:34,550 --> 00:01:41,400
Now let's look at this digital multimeter or Volt or meter.

16
00:01:41,610 --> 00:01:45,740
Uh we must skin set to host predictable.

17
00:01:45,740 --> 00:01:57,300
If we are measuring resistance and we doesn't know or we don't know how much that resistance is we must.

18
00:01:57,300 --> 00:02:00,460
But the scale of the highest value.

19
00:02:00,980 --> 00:02:11,630
Now we the props must be inserted into the sharks as you can see here and we must know the voltage polarity.

20
00:02:11,630 --> 00:02:14,980
As you can see in these two batteries this side is the positive.

21
00:02:14,990 --> 00:02:17,690
And this battery this side is the positive.

22
00:02:18,080 --> 00:02:25,700
So we must bless the positive Rob here and the negative probe here to better measure the voltage.

23
00:02:25,700 --> 00:02:29,860
Now let's look at how we can measure that battery voltage.

24
00:02:29,980 --> 00:02:34,730
Set up the Volt or meter on six hundred volt DC.

25
00:02:34,730 --> 00:02:40,910
As you can see here we are pointing at six hundred volt DC since this is a DC battery.

26
00:02:40,910 --> 00:02:47,930
Uh we much or almost touch red blob two plus as in here as you can see this is the red blob.

27
00:02:48,560 --> 00:02:56,660
And touch a black blob too negative as you can see here then we must read the voltage to the nearest

28
00:02:56,660 --> 00:02:57,590
1 volt.

29
00:02:57,680 --> 00:03:02,310
As you can see here this is a nine volt battery so it's displaying nine.

30
00:03:02,820 --> 00:03:06,130
And uh you can try this at home.

31
00:03:06,140 --> 00:03:08,440
I'm sure that you have wanted me to run the battery.

32
00:03:09,050 --> 00:03:15,930
Uh this is a very simple technique and we must be sure of what we choose.

33
00:03:16,340 --> 00:03:25,700
Uh I'm measuring a DC current here so I choose volt DC for measuring ac I must choose volt AC so you

34
00:03:25,700 --> 00:03:31,370
must take very good care of this setup before I start measuring anything.

35
00:03:32,390 --> 00:03:35,710
And now let's touch the blob.

36
00:03:35,720 --> 00:03:41,820
The negative battery that the blob as you can see here we are reversing the connection and we touch

37
00:03:41,840 --> 00:03:44,930
the black blob to the positive side.

38
00:03:44,930 --> 00:03:46,930
We are reversing the connection.

39
00:03:47,130 --> 00:03:50,730
Uh and we read the voltage to the nearest 1 volt.

40
00:03:50,930 --> 00:03:56,810
As you can see there is a minus sign here which shows the world is negative.

41
00:03:56,810 --> 00:04:04,460
Since we are measuring it in the reverse manner the purpose of this exercise is to show that the Volt

42
00:04:04,490 --> 00:04:08,830
o meter can tell the difference between negative and positive voltages.

43
00:04:09,200 --> 00:04:16,580
We must point out that some Volt or meter particular another type will not be as forgiving that putting

44
00:04:17,000 --> 00:04:20,030
the probes on reverse voltage can damage the meter.

45
00:04:20,030 --> 00:04:29,060
So if you have an analog Volt or meter you shouldn't try this uh just place the positive on the positive

46
00:04:29,060 --> 00:04:33,540
side on the negative on the negative side.

47
00:04:33,560 --> 00:04:45,140
Now let's see if we are to out another to take another example using a vulgar scale that is closer to

48
00:04:45,140 --> 00:04:48,500
the actual voltage shown an improvement in the resolution.

49
00:04:48,560 --> 00:04:55,490
So if we know that this is an eye involved better while choosing a 600 volt scale or if we are or we

50
00:04:55,490 --> 00:05:00,830
know that this battery will measure a Volt between 1 and 20 why choosing 600.

51
00:05:01,100 --> 00:05:04,270
This will decrease the resolution significantly.

52
00:05:04,490 --> 00:05:10,910
Uh in this case we know that this is a 9 volt battery so we are adjusting the scale now set up the rule

53
00:05:10,920 --> 00:05:16,020
involved o meter on 200 volt DC skid touch red blob.

54
00:05:16,030 --> 00:05:19,310
The positive and touch black properties are the negative.

55
00:05:19,940 --> 00:05:23,260
Let's read the voltage to the nearest point to unfold.

56
00:05:23,270 --> 00:05:27,270
Not one volt as you can see in nine point five volt.

57
00:05:27,320 --> 00:05:32,560
Which means that we have a way a much higher resolution.

58
00:05:32,600 --> 00:05:34,440
Uh this is very silly.

59
00:05:34,450 --> 00:05:35,840
There is a zero here.

60
00:05:35,900 --> 00:05:44,630
Now we if we did another adjustment and blazed the Volt o meter and the 200 volt DC scale as you can

61
00:05:44,630 --> 00:05:45,680
see here.

62
00:05:46,280 --> 00:05:53,740
Now let's touch the red blob to the positive and the black blob that are negative and read the voltage

63
00:05:53,790 --> 00:06:03,140
the nearest Born 0 1 volt as you can see here nine point five and the zero claim here unlike the previous

64
00:06:03,140 --> 00:06:03,880
example.

65
00:06:03,920 --> 00:06:06,700
As you can see the Zero was here.

66
00:06:06,980 --> 00:06:07,960
Now it's here.

67
00:06:08,030 --> 00:06:12,210
So we have our much higher resolution.

68
00:06:12,290 --> 00:06:21,200
This is a very good example uh that you must at least have a clue how much the voltage should be or

69
00:06:21,200 --> 00:06:25,760
in what range so that you can get a good result.

70
00:06:25,760 --> 00:06:31,340
Now let's start let's look at this one point five volt battery example.

71
00:06:31,490 --> 00:06:36,200
Set up the Volt or meet up to 20 volt DC touch.

72
00:06:36,200 --> 00:06:43,020
The red blob and the black robe and the positive and negative direction using our unborn 5 volt battery.

73
00:06:43,140 --> 00:06:46,390
Read the voltage thumbnails buoyant 01 volt.

74
00:06:46,400 --> 00:06:48,440
As you can see it's a three.

75
00:06:48,620 --> 00:06:51,580
Breathing is one point five two.

76
00:06:52,090 --> 00:07:03,850
The tool here means that we have a very very high resolution and that we can measure in military volt

77
00:07:03,860 --> 00:07:06,840
range not just the Volt range.

78
00:07:06,860 --> 00:07:16,730
Now let's see the next example in which we will look at the battery but in the middle of volt scale.

79
00:07:16,730 --> 00:07:25,760
Now let's set the Volt on Meet of the 2 200 million volts skin the scale reading two hundred two thousand

80
00:07:25,820 --> 00:07:28,130
Miller Volt or two volts.

81
00:07:28,130 --> 00:07:31,750
Does that add up to the positive and the black blob.

82
00:07:31,750 --> 00:07:32,210
There we go.

83
00:07:32,490 --> 00:07:33,890
OK.

84
00:07:34,020 --> 00:07:37,130
Now we are using the 2000 scare.

85
00:07:37,940 --> 00:07:43,580
Well actually using the two volt scared because two thousand million volts is the same as two volts

86
00:07:44,000 --> 00:07:46,200
but because that simply is in level.

87
00:07:46,220 --> 00:07:53,270
That is not the small point in this case a rating of one thousand five hundred twenty seven million

88
00:07:53,270 --> 00:07:57,110
volt is the same as one point five to seven Volt.

89
00:07:58,160 --> 00:08:06,680
So as you can see here we are using them in the Volt range and we are sitting here and Volt o meter

90
00:08:06,830 --> 00:08:08,510
as you can see now.

91
00:08:08,750 --> 00:08:17,270
And this one point five volt battery we carry the voltage Tony Harris volt 0 0 1 volt and the rating

92
00:08:17,270 --> 00:08:27,440
is given as 1500 to 27 volt it's equal to one point five to seven Volt.

93
00:08:27,890 --> 00:08:29,420
So as the same.

94
00:08:29,630 --> 00:08:33,910
But you just make the resolution however much higher.

95
00:08:34,940 --> 00:08:45,230
Now to see if we want to look at the other example in this example we are setting our volt meter on

96
00:08:45,230 --> 00:08:52,580
2000 level this is scale and we are touching the red blob with the positive and the negative Rob with

97
00:08:52,580 --> 00:08:54,040
the negative side.

98
00:08:54,040 --> 00:09:02,530
We are using a nine volt battery and this is clearly an over voltage situation not reading it Swan.

99
00:09:02,690 --> 00:09:10,120
So you must know what happens if you use a scale that is too low for the voltage being major.

100
00:09:10,310 --> 00:09:16,190
As long as you do not exceed the maximum voltage value of the meter in this case six hundred volt there

101
00:09:16,190 --> 00:09:18,060
will be no physical damage to the meter.

102
00:09:18,560 --> 00:09:24,800
Let me tell indicates an over voltage situation by displaying a single digit one of the far left.

103
00:09:24,800 --> 00:09:33,800
This over a overage indication is consistent with the over all the other functions to be looked at later.

104
00:09:34,070 --> 00:09:41,380
So one means that we have over voltage and we didn't choose the right resolution.

105
00:09:41,390 --> 00:09:49,550
Now let's talk about safety and measuring uh when measuring voltage the voltage being measured execs

106
00:09:49,610 --> 00:09:58,200
is exposed to the operator and flowing through the props by cautions B alternative or be attentive.

107
00:09:58,550 --> 00:10:00,600
Watch what you watch what you touch.

108
00:10:00,620 --> 00:10:03,320
We shouldn't touch the props while measuring voltage.

109
00:10:03,570 --> 00:10:08,090
The blobs have sharp buoyant so that you can make precious contact.

110
00:10:08,100 --> 00:10:14,340
Use the protective shields when probes not in use so that they won't harm anyone.

111
00:10:14,350 --> 00:10:22,860
Observe the meter maximum limits for voltage and current fuels are a last resort protection feature.

112
00:10:22,940 --> 00:10:27,510
If you blow a fuse you made a mistake a very big one actually.

113
00:10:27,680 --> 00:10:36,830
So you must spend some time in safety so that you won't get harm or you won't harm anyone around you.

114
00:10:38,960 --> 00:10:45,560
The operators of the Volt meter could be exposed to lethal voltage and current levels also in probing

115
00:10:45,710 --> 00:10:53,150
alive circuit careless cross contact and the resulting short circuits could draw out equipment damaging

116
00:10:53,150 --> 00:10:56,620
levels of voltage and current the circuit under test.

117
00:10:56,780 --> 00:11:04,340
So you might harm the circuit damage components while measuring all while using digital multimeter or

118
00:11:04,340 --> 00:11:10,680
Volt or meter uh you must practice before going to circuits.

119
00:11:10,690 --> 00:11:16,220
You must practice with the components you must practice with damaged circuits then go to the real life

120
00:11:16,220 --> 00:11:19,480
circuits and real life problems.

121
00:11:19,550 --> 00:11:27,460
A good technique is the do a dry run of broad placement with mouth turned off during the dry run.

122
00:11:27,500 --> 00:11:34,970
The operator can see if the probe placement is correct and not short circuiting to damaging voltage

123
00:11:35,210 --> 00:11:37,170
and current breaths.

124
00:11:37,190 --> 00:11:43,430
Probably Osment and once confidence turn on the ball source to make the measurement another good technique

125
00:11:43,520 --> 00:11:49,190
is to sort all measurement of the high scaling level and then adjust the scale down downward to the

126
00:11:49,190 --> 00:11:50,720
appropriate living.

127
00:11:50,750 --> 00:11:58,020
There are usually automatic protection features involved or meters but it is the best or it is best

128
00:11:58,020 --> 00:12:04,500
not to consistently depend on them doing their intended jobs.

129
00:12:04,560 --> 00:12:08,460
That's it for measuring voltage and for safety and measuring voltage.

130
00:12:08,520 --> 00:12:17,460
I know that this lesson was really long but I'm sure that you learned a lot of things in one lecture

131
00:12:18,480 --> 00:12:25,770
and we kept it connected since this all experience are related to each other.

132
00:12:25,770 --> 00:12:26,970
Thanks for watching.

133
00:12:26,970 --> 00:12:29,370
See you next in measuring color.