1
00:00:01,590 --> 00:00:02,640
Hello.

2
00:00:02,700 --> 00:00:06,240
Today we will learn about measuring resistance

3
00:00:09,750 --> 00:00:12,960
when the Volt o meter is used to measure resistance.

4
00:00:13,230 --> 00:00:19,340
What actually is measured is a small voltage and current applied to the component.

5
00:00:19,350 --> 00:00:25,780
There are five ranges and out of resistance reading will indicate a single one digit.

6
00:00:25,890 --> 00:00:35,610
Remember k means multiple the reading by 1000 operating voltage should be removed from the component

7
00:00:35,670 --> 00:00:36,990
under test.

8
00:00:36,990 --> 00:00:44,250
Or you could damage the Volt or meter at worst all the reading could be false at best.

9
00:00:45,790 --> 00:00:52,450
When measuring these tunnels there is a small voltage supplied by the meter to energize the controller

10
00:00:53,460 --> 00:00:54,680
the red blob.

11
00:00:54,980 --> 00:01:02,270
Lead would have the Positive voltage the Volt on the measure the voltage and current flowing through

12
00:01:02,270 --> 00:01:11,150
the component and the resistance is calculated using arms low which will be converted later.

13
00:01:11,260 --> 00:01:18,970
You can go through the five ranges 200 hundred read up to two hundred ohms two thousand will read up

14
00:01:18,970 --> 00:01:30,760
to 2000 ohm twenty K will lead up to to twenty thousand on and two hundred K will read up to two hundred

15
00:01:30,760 --> 00:01:42,300
thousand ohm while 2000 K read up to two million on or two mega on if their power is removed from the

16
00:01:42,300 --> 00:01:43,090
circuit.

17
00:01:43,260 --> 00:01:47,010
There is little danger that the Volt arm could be damaged.

18
00:01:48,420 --> 00:01:53,100
So you need to remove the ball before starting the test.

19
00:01:53,100 --> 00:01:56,040
Now let's look at an example.

20
00:01:56,040 --> 00:01:59,630
Measuring resistance disconnect the battery from the ball.

21
00:01:59,640 --> 00:02:01,790
Remember to measure resistance.

22
00:02:01,890 --> 00:02:09,010
The Circuit should be unbound both the hundred on resistor in place no additional wires are required.

23
00:02:09,360 --> 00:02:18,210
Select the 200 range and touch the prob leads to either side of that is a store it will read ninety

24
00:02:18,810 --> 00:02:21,370
eight point zero.

25
00:02:21,390 --> 00:02:27,900
Now if we looked here this set of flares the prob leads and observe the reading.

26
00:02:28,320 --> 00:02:31,070
As you can see there is no difference.

27
00:02:31,110 --> 00:02:35,850
It's the same reading ninety eight point zero.

28
00:02:35,910 --> 00:02:47,590
So this means that there is a store doesn't have ability and you can measure at any of these sides.

29
00:02:47,600 --> 00:02:54,280
Now let's take another example where we can discuss those solution using the hundred on the store.

30
00:02:54,320 --> 00:02:57,570
This measure of resistance using each of the other ranges.

31
00:02:57,650 --> 00:02:59,580
This is the two hundred two thousand.

32
00:02:59,750 --> 00:03:12,980
As you can see 0 8 9 and in 2k at 1 taking as you can see zero point one zero the two hundred K zero

33
00:03:12,980 --> 00:03:16,550
zero point one the 2000 case zero zero zero.

34
00:03:16,640 --> 00:03:24,280
So it's like out French and we can't possibly measure that there's a store which is 100 on using that

35
00:03:24,280 --> 00:03:25,820
all mega on a scale.

36
00:03:25,850 --> 00:03:30,500
This will be seriously wrong and we won't get a value.

37
00:03:30,620 --> 00:03:37,760
Not that the solution of their eating decreases as the maximum on reading increase down to the point

38
00:03:37,760 --> 00:03:44,190
where it is difficult to get a good resistance reading which is in this example.

39
00:03:44,230 --> 00:03:55,660
Now if we look at another example as you can see here using the one killer on the stores and the 200

40
00:03:55,670 --> 00:04:00,800
range this is what we get.

41
00:04:00,870 --> 00:04:04,230
We used one kilo arm which is 1000 all.

42
00:04:04,390 --> 00:04:07,730
A much larger than 200 on the end.

43
00:04:07,920 --> 00:04:17,130
So uh it's a blade one which means that that is uh everything that is out of range.

44
00:04:17,170 --> 00:04:21,470
We must find the appropriate range to measuring the one kilo arm.

45
00:04:21,670 --> 00:04:29,680
So if we use the two thousand on reading it will give us nine hundred eighty four.

46
00:04:29,770 --> 00:04:39,010
As you can see here which is the best resolution for measuring the one kid or so you must choose the

47
00:04:39,010 --> 00:04:41,050
resolution wisely.

48
00:04:41,230 --> 00:04:49,020
Otherwise you will get you will get error or you won't get an accurate result.

49
00:04:49,090 --> 00:05:03,070
And this will let's say that this will damage your calculations because you must choose the right resolution.

50
00:05:03,080 --> 00:05:12,020
So you need to try different resolutions to get the best value with as minimum as possible.

51
00:05:12,090 --> 00:05:16,920
Zeros in the left side and in that case the two thousand.

52
00:05:16,980 --> 00:05:24,770
The trick for us now you think you're on the 100 kilometers a store first that amount appropriate range

53
00:05:24,770 --> 00:05:26,840
to use for each resistor.

54
00:05:26,870 --> 00:05:30,410
Second make the resistance measurement.

55
00:05:30,500 --> 00:05:36,550
Third using higher ranges to predict the reading and confirm your prediction by taking damage.

56
00:05:37,340 --> 00:05:39,630
This is a good practice that you should do.

57
00:05:39,950 --> 00:05:42,290
And these are really simple.

58
00:05:43,280 --> 00:05:49,240
Let's say a really simple steps that you can apply now.

59
00:05:49,790 --> 00:05:50,510
Just for fun.

60
00:05:50,510 --> 00:06:00,220
Use the volt meter to measure the resistance of all your different body parts the voltage and current

61
00:06:00,220 --> 00:06:05,920
used by the Volt o meter is not dangerous so you can measure that this that resistance through your

62
00:06:05,920 --> 00:06:13,210
body discuss your observations and how your measurement techniques could influence the readings you

63
00:06:13,240 --> 00:06:19,040
get from the Volt o meter and I think that this is a really fun example.

64
00:06:19,100 --> 00:06:28,420
Practice blobs across individual finned finger or read around one point it make it on probes held between

65
00:06:28,420 --> 00:06:37,960
thumbs and finger one in each hand will measure one point for go on props form the skin on the ankle

66
00:06:38,140 --> 00:06:47,800
and skin on the hand will get you a scale of breathing dry skin vs. moist skin dry one may get warm

67
00:06:47,860 --> 00:06:57,950
moist 96 scale or on lightly touching it probs compared to a free up grasp onto probs light is one may

68
00:06:57,950 --> 00:07:07,150
go home while firm is 300 kilo on the point here is that body contact with the blobs during measurement

69
00:07:07,180 --> 00:07:15,640
can influence the o meter reading and should be avoided practice particularly when measuring high values

70
00:07:15,730 --> 00:07:25,030
of resistance you can bring this up again and try it yourself at home you will know that once you touch

71
00:07:25,030 --> 00:07:30,040
the two blobs it will display resistance so you need to avoid direct contact with the resistance when

72
00:07:30,040 --> 00:07:40,420
measuring it since the this will damage your reading or give you a false reading so please take care

73
00:07:40,420 --> 00:07:50,160
of this very important note when using the volt meter or digital multimeter to measure resistance.

74
00:07:50,170 --> 00:07:51,130
Thanks for watching.

75
00:07:51,130 --> 00:07:52,870
This is education and engineering team.