1 00:00:00,630 --> 00:00:02,980 Basic component testing. 2 00:00:03,270 --> 00:00:09,900 Now we are going to start with the fuse physical appearance of God and blown fuse. 3 00:00:09,930 --> 00:00:13,040 As you can see this is a good fuse. 4 00:00:13,350 --> 00:00:22,240 This fuse has a slight permed and these two fuses are completely damaged disc. 5 00:00:22,250 --> 00:00:26,670 Color means a major short circuit in the equipment. 6 00:00:26,670 --> 00:00:32,470 As you can see you can't see anything through the glass. 7 00:00:32,610 --> 00:00:39,120 Now there is also a multimeter indication for good and blowing fuse that would fuse. 8 00:00:39,150 --> 00:00:46,110 As you can see here will give you zeros and the blown fuse will give you one. 9 00:00:46,200 --> 00:00:48,260 This is usually done using a fuse. 10 00:00:48,270 --> 00:00:57,870 This and the multimeter itself now in order to test this fuse using a multimeter. 11 00:00:57,870 --> 00:01:06,950 You must use the connectivity or continue at test function rotate your potential meter dial until you 12 00:01:06,950 --> 00:01:08,650 reach the buzzer. 13 00:01:08,720 --> 00:01:17,750 Or can it continue to shape symbol then connect these two terminals to the two terminals of the fuse. 14 00:01:17,750 --> 00:01:23,930 Now if the fuse is working if a conductive path is formed the multimeter will be. 15 00:01:24,140 --> 00:01:28,980 This means that the fuse is working and there is no problem. 16 00:01:29,090 --> 00:01:36,410 Now if the fuse is cut off it's blowing away or if it has a problem. 17 00:01:36,470 --> 00:01:41,280 Once you bless these two terminals the conductive path is broken. 18 00:01:41,480 --> 00:01:49,180 So the multimeter will not beep This is the simplest way to test a fuse using the connectivity test 19 00:01:49,750 --> 00:01:51,710 in your digital multimeter. 20 00:01:52,070 --> 00:01:56,390 And this is carved out in the practical section at the end of this course. 21 00:01:56,620 --> 00:02:03,670 But for now this is how to test a fuse first using the shape if the physical layout wasn't enough. 22 00:02:03,670 --> 00:02:10,570 And if you couldn't figure out if it is blowing or not you can move on to the continued test and see 23 00:02:10,690 --> 00:02:18,100 if your digital multimeter will be or not if it does beep this. 24 00:02:18,110 --> 00:02:21,520 This means that the mole on the fuse is working. 25 00:02:21,520 --> 00:02:25,830 If it didn't beep This means that the fuse is not working. 26 00:02:27,060 --> 00:02:28,820 That's it for how to twist a fuse. 27 00:02:28,860 --> 00:02:31,730 If you have any question please ask and you on a board. 28 00:02:31,830 --> 00:02:32,640 Thanks for watching. 29 00:02:32,640 --> 00:02:35,370 This is Ashraf from educational engineering team.