WEBVTT

0:00:03.060000 --> 0:00:08.020000
 Hello and welcome to this video
 titled Power over Ethernet.

0:00:08.020000 --> 0:00:12.760000
 In this video I'm going to cover what
 is power over Ethernet and why do

0:00:12.760000 --> 0:00:17.280000
 we need it? What types of things can
 be powered with this technology?

0:00:17.280000 --> 0:00:20.560000
 What are some of the benefits
 of power over Ethernet?

0:00:20.560000 --> 0:00:25.860000
 These acronyms of PSE and PD
 will define what they mean.

0:00:25.860000 --> 0:00:31.780000
 We'll talk about how much power can be sent
 with power over Ethernet standards.

0:00:31.780000 --> 0:00:35.500000
 How exactly is the
 power delivered?

0:00:35.500000 --> 0:00:37.700000
 Detection and negotiation.

0:00:37.700000 --> 0:00:41.300000
 How does a power over Ethernet device
 know that what it's connected to

0:00:41.300000 --> 0:00:43.740000
 even needs power in
 the first place?

0:00:43.740000 --> 0:00:47.620000
 And we'll look at some power over Ethernet
 monitoring techniques, specifically

0:00:47.620000 --> 0:00:52.720000
 using a couple of Cisco
 specific iOS commands.

0:00:52.720000 --> 0:00:56.580000
 So let's start with why do we
 need power over Ethernet?

0:00:56.580000 --> 0:00:58.820000
 Well, let's take a step
 back here for a second.

0:00:58.820000 --> 0:01:00.680000
 What is power over Ethernet?

0:01:00.680000 --> 0:01:06.260000
 Like the term sounds, it's this idea of
 running an Ethernet cable to something.

0:01:06.260000 --> 0:01:10.260000
 And normally we think of an Ethernet
 cable as having the data go back

0:01:10.260000 --> 0:01:11.540000
 and forth on that cable.

0:01:11.540000 --> 0:01:14.060000
 And whatever that thing is, it's connected
 to the Ethernet cable, whether

0:01:14.060000 --> 0:01:20.140000
 it be a laptop, a PC, an IP phone would
 have a separate AC connector to

0:01:20.140000 --> 0:01:21.500000
 power that device.

0:01:21.500000 --> 0:01:24.760000
 Well, power over Ethernet says, hey,
 let's get rid of the AC connector

0:01:24.760000 --> 0:01:29.380000
 and run power over the same Ethernet
 cable that's being used to deliver

0:01:29.380000 --> 0:01:34.700000
 our data. We know that all host devices
 that connect to a network require

0:01:34.700000 --> 0:01:36.200000
 some kind of a power.

0:01:36.200000 --> 0:01:42.480000
 Laptops, PCs, printers, IP phones, Internet
 of Things devices like your

0:01:42.480000 --> 0:01:46.080000
 IP cameras and your thermostats
 and things of that nature.

0:01:46.080000 --> 0:01:50.520000
 Well, all these things need power and
 if they aren't battery driven, they're

0:01:50.520000 --> 0:01:54.000000
 going to be driven basically by
 plugging into an AC outlet.

0:01:54.000000 --> 0:01:58.440000
 And sometimes, due to the placement
 of where you want this thing to be,

0:01:58.440000 --> 0:02:02.480000
 finding a close and available AC outlet
 to run a power cord to this thing

0:02:02.480000 --> 0:02:06.120000
 isn't feasible or practical.

0:02:06.120000 --> 0:02:11.480000
 So for this reason, power over Ethernet
 gives us a practical, useful alternative

0:02:11.480000 --> 0:02:16.120000
 way to run power to that device over
 the same cable that's being used

0:02:16.120000 --> 0:02:17.640000
 to transmit the data.

0:02:17.640000 --> 0:02:22.220000
 So essentially, we're going from this,
 where we have a variety of devices

0:02:22.220000 --> 0:02:23.980000
 that have two cables.

0:02:23.980000 --> 0:02:27.320000
 The black cable represents your network
 data cable that's going to the

0:02:27.320000 --> 0:02:31.160000
 switch. And then you have the red line
 here, which represents your AC

0:02:31.160000 --> 0:02:33.140000
 power that's being used
 to power the device.

0:02:33.140000 --> 0:02:38.380000
 We're going from that to this, where the
 one cable's being used to transmit

0:02:38.380000 --> 0:02:43.100000
 both things. So I think you can start
 to see the benefits here of power

0:02:43.100000 --> 0:02:47.040000
 over Ethernet. Certainly, there's
 a time and cost savings.

0:02:47.040000 --> 0:02:51.900000
 We have to run less cables around walls,
 around cabinets, into the ceiling

0:02:51.900000 --> 0:02:54.520000
 and so on and so forth.

0:02:54.520000 --> 0:02:58.780000
 So not only is there less cost, because
 there's less cables we got to

0:02:58.780000 --> 0:03:04.300000
 deal with purchasing, less AC adapters
 we have to worry about purchasing,

0:03:04.300000 --> 0:03:07.380000
 but there's also cost savings
 from time, right?

0:03:07.380000 --> 0:03:11.720000
 How long does it take to string one
 cable up into the wall, up into the

0:03:11.720000 --> 0:03:16.140000
 ceiling versus two cables,
 or multiple cables?

0:03:16.140000 --> 0:03:17.880000
 There's also flexibility.

0:03:17.880000 --> 0:03:21.500000
 Basically, it boils down to, hey, if
 you can run an Ethernet cable to

0:03:21.500000 --> 0:03:26.240000
 that location, you can put a power over
 Ethernet device at that location.

0:03:26.240000 --> 0:03:32.140000
 Safety. Power over Ethernet, the delivery
 of the power is intelligent

0:03:32.140000 --> 0:03:36.320000
 and designed to protect the network equipment
 from overload under powering

0:03:36.320000 --> 0:03:37.920000
 or incorrect installation.

0:03:37.920000 --> 0:03:41.520000
 So the idea with power over Ethernet
 is that the device providing the

0:03:41.520000 --> 0:03:45.620000
 power will not only detect if the device
 at the other end of the cable

0:03:45.620000 --> 0:03:50.320000
 needs power, but just how much power
 is needed so we don't overload or

0:03:50.320000 --> 0:03:52.020000
 burn out that device.

0:03:52.020000 --> 0:03:56.640000
 Also from a safety perspective, how
 often have you been traveling maybe

0:03:56.640000 --> 0:03:59.660000
 internationally and used an
 international power adapter?

0:03:59.660000 --> 0:04:02.300000
 Man, that thing got hot
 after a while, right?

0:04:02.300000 --> 0:04:06.140000
 When you touched it to unplug it from
 the wall, it was pretty toasty.

0:04:06.140000 --> 0:04:10.160000
 Well, sometimes those things can catch
 fire from a power standpoint.

0:04:10.160000 --> 0:04:13.980000
 Hey, if my Ethernet cable is running
 the power, it's a lot safer than

0:04:13.980000 --> 0:04:17.700000
 a mishmash of different power adapters
 I have based on where this device

0:04:17.700000 --> 0:04:22.040000
 is going to be. And reliability.

0:04:22.040000 --> 0:04:25.820000
 The power that's coming is coming from
 a central and universally compatible

0:04:25.820000 --> 0:04:29.620000
 source. Going right back to that
 same analogy I had again.

0:04:29.620000 --> 0:04:39.360000
 If you have a device, take your pick,
 an IP camera or think of some small

0:04:39.360000 --> 0:04:43.880000
 Internet of Thing device that you're
 going to connect to the network.

0:04:43.880000 --> 0:04:48.560000
 Now imagine if that device right now
 is with you and you are in the United

0:04:48.560000 --> 0:04:53.200000
 States, well, you're going to have a
 certain type of AC adapter or jack

0:04:53.200000 --> 0:04:56.620000
 or connector. You're going to have to
 plug into that thing to plug into

0:04:56.620000 --> 0:05:00.320000
 the wall jack. If you take that same
 device with you on a plane and you

0:05:00.320000 --> 0:05:05.020000
 go to Europe or South America or Africa,
 they have completely different

0:05:05.020000 --> 0:05:07.120000
 wall jacks with completely
 different plugs.

0:05:07.120000 --> 0:05:09.940000
 So there's not going to be
 any standardization here.

0:05:09.940000 --> 0:05:11.840000
 It's not going to be reliable.

0:05:11.840000 --> 0:05:16.660000
 Whereas that same thing, if it's power
 via Ethernet, Ethernet is used

0:05:16.660000 --> 0:05:19.380000
 all across the world, all across the
 world that use standard Ethernet

0:05:19.380000 --> 0:05:21.920000
 cables with RJ45 jacks.

0:05:21.920000 --> 0:05:25.160000
 So whether that device is being powered
 in Africa, Europe or the United

0:05:25.160000 --> 0:05:32.560000
 States, it's receiving that power
 on a standard RJ45 connection.

0:05:32.560000 --> 0:05:33.520000
 Also scalability.

0:05:33.520000 --> 0:05:36.520000
 Scalability. So if we go back to that
 previous picture that we just looked

0:05:36.520000 --> 0:05:37.920000
 at, look at this.

0:05:37.920000 --> 0:05:41.840000
 So in this situation here on the left
 with just those three things, I

0:05:41.840000 --> 0:05:43.540000
 need three power adapters.

0:05:43.540000 --> 0:05:48.100000
 Or I should say three wall jacks
 that they can plug into.

0:05:48.100000 --> 0:05:58.420000
 So what if I've got 30
 things or 300 things?

0:05:58.420000 --> 0:06:01.720000
 So I'm going to say that power
 bricks is not very scalable.

0:06:01.720000 --> 0:06:04.960000
 Whereas once again, I could have
 a switch, a 48 port switch.

0:06:04.960000 --> 0:06:08.280000
 And if all 40 of those ports are capable
 of supplying power, that's like

0:06:08.280000 --> 0:06:12.900000
 48 wall jacks all condensed into one
 box, which now the cables can be

0:06:12.900000 --> 0:06:17.340000
 run out 100 meters in any given direction
 and provide power to whatever

0:06:17.340000 --> 0:06:21.400000
 is connected to it.

0:06:21.400000 --> 0:06:26.240000
 All right, so let's talk about a
 couple of terms here, PSD and PD.

0:06:26.240000 --> 0:06:28.360000
 If you're going to deal with power over
 Ethernet, you have to know what

0:06:28.360000 --> 0:06:30.260000
 these stand for.

0:06:30.260000 --> 0:06:33.040000
 So power over Ethernet, there are
 a variety of standards for it.

0:06:33.040000 --> 0:06:35.400000
 They have evolved over time.

0:06:35.400000 --> 0:06:42.460000
 So there's 802.3 AF, AT and the latest,
 which is 802.3 BT, which is standardized

0:06:42.460000 --> 0:06:49.340000
 in mid 2018. And all of these categorize
 power over Ethernet devices is

0:06:49.340000 --> 0:06:51.760000
 belonging to one of
 two categories.

0:06:51.760000 --> 0:06:54.740000
 You've got the power
 sourcing equipment.

0:06:54.740000 --> 0:06:58.740000
 So like it sounds, that would be your
 device that's pushing power down

0:06:58.740000 --> 0:07:02.420000
 the wire. This would typically be a
 network switch, which would be your

0:07:02.420000 --> 0:07:04.680000
 power sourcing equipment
 or your PSE.

0:07:04.680000 --> 0:07:08.320000
 And then you have at the other end of
 that cable, a PD, a power device,

0:07:08.320000 --> 0:07:13.940000
 such as your wireless access point, or
 your IP phone, or your IP, or your

0:07:13.940000 --> 0:07:16.280000
 IP, or your IP. So you have to have
 a USB camera or something like that.

0:07:16.280000 --> 0:07:22.340000
 So PSEs are typically network switches,
 or they could be power injectors.

0:07:22.340000 --> 0:07:25.900000
 So for example, here's an example
 of a couple of power injectors.

0:07:25.900000 --> 0:07:30.180000
 Now, notice that the power injectors
 themselves, like these two pictures

0:07:30.180000 --> 0:07:33.520000
 right here, they plug into
 wall outlet, don't they?

0:07:33.520000 --> 0:07:36.800000
 Don't they? Both of them have plugs
 that plug into wall outlet.

0:07:36.800000 --> 0:07:40.020000
 So when would you use
 something like that?

0:07:40.020000 --> 0:07:45.120000
 Well, this would be a case of something
 where maybe I have a switch that

0:07:45.120000 --> 0:07:48.020000
 does not provide power
 over Ethernet.

0:07:48.020000 --> 0:07:51.200000
 The switch I bought doesn't provide
 that, or maybe I've maxed it out and

0:07:51.200000 --> 0:07:52.740000
 I've got a few more ports.

0:07:52.740000 --> 0:07:55.760000
 So I've got some ports that provide
 power over Ethernet, but those are

0:07:55.760000 --> 0:07:59.440000
 all used up. I have other ports left
 on that switch that I can plug things

0:07:59.440000 --> 0:08:01.700000
 into, but those are
 not powered ports.

0:08:01.700000 --> 0:08:03.140000
 They don't supply power.

0:08:03.140000 --> 0:08:06.860000
 Either way, I can't run power down the
 cable, and what if the other side

0:08:06.860000 --> 0:08:14.540000
 of the cable is not something that
 supports what if we had an Internet

0:08:14.540000 --> 0:08:19.580000
 of Thing device that doesn't plug in,
 something that relies on power over

0:08:19.580000 --> 0:08:22.860000
 Ethernet, where the only way you could
 power that thing is if you plug

0:08:22.860000 --> 0:08:24.160000
 an Ethernet cable into it.

0:08:24.160000 --> 0:08:27.580000
 It doesn't even have jacks where you could
 plug it into a wall or something

0:08:27.580000 --> 0:08:29.760000
 like that. Well, now I have
 an incompatibility.

0:08:29.760000 --> 0:08:35.880000
 I have a powered device without any
 AC capability, and yet I've got a

0:08:35.880000 --> 0:08:39.460000
 switch which can't send
 power to that device.

0:08:39.460000 --> 0:08:41.800000
 That's where you'd use something
 like this power injector here.

0:08:41.800000 --> 0:08:54.040000
 The switch would have an Ethernet cable
 that runs down to the power injector.

0:08:54.040000 --> 0:08:58.960000
 And that would lead down
 to the power device.

0:08:58.960000 --> 0:09:03.980000
 So how much power can you get
 from power over Ethernet?

0:09:03.980000 --> 0:09:07.920000
 Well, as I mentioned, the standards
 have evolved over time.

0:09:07.920000 --> 0:09:14.640000
 So the original standard 802.3 AF supplied
 up to 15.4 watts for the power

0:09:14.640000 --> 0:09:21.140000
 device, and the latest standards, which
 is 802.3 BT, which also goes by

0:09:21.140000 --> 0:09:24.020000
 the name of UPOE plus that's 7.0.

0:09:24.020000 --> 0:09:29.840000
 And the Cisco's proprietary way of
 implementing 802.3 BT can supply up

0:09:29.840000 --> 0:09:33.060000
 to 90 to 95 watts
 per power device.

0:09:33.060000 --> 0:09:37.760000
 Now one thing to know about these numbers
 here in this chart under the

0:09:37.760000 --> 0:09:43.280000
 power budget per device is that those
 numbers there are how much power

0:09:43.280000 --> 0:09:46.380000
 is leaving the port on the switch.


0:09:46.380000 --> 0:09:50.120000
 But not all of that power is going
 to get down to the power device at

0:09:50.120000 --> 0:09:54.760000
 the other end. Some of it is going to
 dissipate as like heat or electrical

0:09:54.760000 --> 0:09:57.400000
 resistance within the
 cabling itself.

0:09:57.400000 --> 0:10:01.920000
 So most of it reaches the power
 device, but not all of it.

0:10:01.920000 --> 0:10:03.440000
 So just be aware of that.

0:10:03.440000 --> 0:10:08.480000
 Also one thing to mention here,
 notice how it says power budget.

0:10:08.480000 --> 0:10:09.940000
 Actually there's a little
 bit of a spelling there.

0:10:09.940000 --> 0:10:13.160000
 It says budge, but it should
 say power budget per device.

0:10:13.160000 --> 0:10:15.940000
 You should know what that
 term power budget means.

0:10:15.940000 --> 0:10:20.980000
 So when you buy a switch that's a power
 over ethernet capable switch,

0:10:20.980000 --> 0:10:25.600000
 they might say, hey the power budget
 of the switch is 540 watts.

0:10:25.600000 --> 0:10:29.340000
 So what they're talking about is that's
 the maximum power it can deliver

0:10:29.340000 --> 0:10:31.940000
 to the power devices.

0:10:31.940000 --> 0:10:36.780000
 Now that power might be spread out over
 all the ports in the switch, or

0:10:36.780000 --> 0:10:41.140000
 depending on what you're powering up,
 after you use like 10 or 15 ports,

0:10:41.140000 --> 0:10:43.740000
 maybe your entire power budget.

0:10:43.740000 --> 0:10:47.900000
 And you don't have any power left to
 deliver to some of the other ports.

0:10:47.900000 --> 0:10:50.420000
 So you'll hear that
 term power budget.

0:10:50.420000 --> 0:10:51.240000
 And that's what that means.

0:10:51.240000 --> 0:10:56.200000
 The total power available for a power
 sourcing equipment to send down

0:10:56.200000 --> 0:11:00.760000
 to its total quantity
 of powered devices.

0:11:00.760000 --> 0:11:03.040000
 So how is the power delivered?

0:11:03.040000 --> 0:11:05.680000
 Well, it really depends on the standard
 that we're dealing with.

0:11:05.680000 --> 0:11:11.280000
 We know the ethernet cables are eight wires
 total, so we call this unshielded

0:11:11.280000 --> 0:11:16.900000
 twisted pair. So here you can see
 each one of these things here.

0:11:16.900000 --> 0:11:21.260000
 So like right there, that's
 a pair of wires.

0:11:21.260000 --> 0:11:26.360000
 Right, we've got a white wire and a
 sort of lime green colored wire and

0:11:26.360000 --> 0:11:27.580000
 they're twisted together.

0:11:27.580000 --> 0:11:32.260000
 So this is called a twisted pair.

0:11:32.260000 --> 0:11:37.760000
 And you can see if that's two,
 well that'd be 4, 6, 8.

0:11:37.760000 --> 0:11:41.900000
 So within this one category 5E cable,
 there's actually eight wires in

0:11:41.900000 --> 0:11:45.180000
 there which are twisted
 together in pairs.

0:11:45.180000 --> 0:11:49.820000
 Now depending on the power over ethernet
 standard that you're using will

0:11:49.820000 --> 0:11:56.620000
 determine how many of those pairs are
 actually used to transmit the power.

0:11:56.620000 --> 0:12:01.440000
 So when you're talking about the earlier
 standards of 802.3 AF and 802

0:12:01.440000 --> 0:12:06.440000
.3 AT, those utilized
 two of the pairs.

0:12:06.440000 --> 0:12:10.260000
 So actually two of the pairs
 were used just for data.

0:12:10.260000 --> 0:12:13.320000
 Two other pairs were
 used for the power.

0:12:13.320000 --> 0:12:17.080000
 So that one cable within
 it separated out.

0:12:17.080000 --> 0:12:19.500000
 Some wires were used just
 to deliver the power.

0:12:19.500000 --> 0:12:21.960000
 Other wires were used just
 to deliver the data.

0:12:21.960000 --> 0:12:26.780000
 Then once they came up with the newer
 standards of like 802.3BT which

0:12:26.780000 --> 0:12:30.720000
 Cisco does in their own sort of way called
 universal power over ethernet.

0:12:30.720000 --> 0:12:34.800000
 Now we're talking about using all the
 pairs, all eight wires to carry

0:12:34.800000 --> 0:12:37.440000
 both data and power.

0:12:37.440000 --> 0:12:40.340000
 And it gets kind of complicated as
 to how it actually does that at the

0:12:40.340000 --> 0:12:43.120000
 physical level but
 just know it works.

0:12:43.120000 --> 0:12:47.340000
 It is capable of doing that.

0:12:47.340000 --> 0:12:51.060000
 So the last thing I want to talk about
 here is when something plugs into

0:12:51.060000 --> 0:12:55.820000
 an ethernet switch that's capable of
 delivering power over ethernet, that

0:12:55.820000 --> 0:13:00.460000
 ethernet switch needs to know is the thing
 that just plugged into me something

0:13:00.460000 --> 0:13:02.260000
 that needs my power?

0:13:02.260000 --> 0:13:05.720000
 Like maybe what plugged into me is
 a laptop that has his own separate

0:13:05.720000 --> 0:13:08.560000
 AC connector. I don't need to
 send power to that device.

0:13:08.560000 --> 0:13:10.380000
 It's being powered separately.

0:13:10.380000 --> 0:13:13.720000
 Or maybe what just plugged
 into me is an IP phone.

0:13:13.720000 --> 0:13:15.760000
 And that thing needs
 me to power it up.

0:13:15.760000 --> 0:13:17.600000
 Well, how's it know?

0:13:17.600000 --> 0:13:20.260000
 And we're going to talk at a real high
 level here just for a minute on

0:13:20.260000 --> 0:13:23.400000
 how that detection process
 takes place.

0:13:23.400000 --> 0:13:28.140000
 So when power over ethernet is enabled
 on a port, here's what happens.

0:13:28.140000 --> 0:13:32.040000
 First of all we need to know, are we
 connected to a power device or not?

0:13:32.040000 --> 0:13:35.320000
 And if so, how much
 power does it need?

0:13:35.320000 --> 0:13:39.660000
 Because remember we can go from 15.4
 watts all the way up to like 90 watts

0:13:39.660000 --> 0:13:42.220000
 depending on which standard
 we're dealing with.

0:13:42.220000 --> 0:13:45.200000
 So here's a summary of the initial
 steps we're going to go through.

0:13:45.200000 --> 0:13:49.460000
 Number one, the power sourcing
 equipment, i.e.

0:13:49.460000 --> 0:13:54.040000
 network switch, will output a small
 amount of power to detect if there's

0:13:54.040000 --> 0:13:56.420000
 any resistance. If there's
 any resistance.

0:13:56.420000 --> 0:13:59.360000
 So power's going to go out and it's
 going to see if any of that power

0:13:59.360000 --> 0:14:02.840000
 comes back on a separate
 cable or a separate wire.

0:14:02.840000 --> 0:14:08.960000
 Now if we're talking about a powered device
 like an IP phone or a surveillance

0:14:08.960000 --> 0:14:12.520000
 camera that's an IP surveillance camera
 that needs power over ethernet,

0:14:12.520000 --> 0:14:16.700000
 that device will have on the wire that's
 receiving the power, special

0:14:16.700000 --> 0:14:18.340000
 resistors in it.

0:14:18.340000 --> 0:14:23.740000
 So when it sort of loops the power back
 to the power sourcing equipment,

0:14:23.740000 --> 0:14:27.040000
 it'll change it in a little way, like
 a little bit less power will be

0:14:27.040000 --> 0:14:30.600000
 looped back than what came
 down from the switch.

0:14:30.600000 --> 0:14:35.300000
 That's how the switch will know, okay,
 I'm connected to a power device.

0:14:35.300000 --> 0:14:38.780000
 Because if the device I was connected
 to was not a power device like a

0:14:38.780000 --> 0:14:42.900000
 laptop, the amount of electrical energy
 I sent down, which is very, very,

0:14:42.900000 --> 0:14:46.560000
 very tiny. It's not enough to hurt
 the NIC card or hurt the device at

0:14:46.560000 --> 0:14:50.820000
 all. That amount that I sent down would
 be reflected back to me in full.

0:14:50.820000 --> 0:14:51.640000
 It wouldn't be changed.

0:14:51.640000 --> 0:14:54.360000
 And so I'd know, okay, there's
 no resistor down there.

0:14:54.360000 --> 0:14:57.360000
 There's nothing that's blocking
 it or reducing it.

0:14:57.360000 --> 0:15:01.840000
 So therefore, whatever that device
 is, is not a powered device.

0:15:01.840000 --> 0:15:07.740000
 But the amount of electrical energy
 I get back is a little bit less than

0:15:07.740000 --> 0:15:08.700000
 what I sent down.

0:15:08.700000 --> 0:15:11.680000
 And there's a certain ratio, can't just
 be some random amount less, power

0:15:11.680000 --> 0:15:15.140000
 over ethernet says, okay, it's got
 to fall within this threshold here.

0:15:15.140000 --> 0:15:18.400000
 If the amount you got back is within
 this threshold and those details

0:15:18.400000 --> 0:15:21.420000
 are more than we need to know for this
 video, but if it's within this

0:15:21.420000 --> 0:15:24.320000
 threshold, that is
 a powered device.

0:15:24.320000 --> 0:15:28.280000
 Okay, so now what happens is the power
 source equipment will start sending

0:15:28.280000 --> 0:15:33.240000
 a little bit of power just enough to
 sort of like bring that device up

0:15:33.240000 --> 0:15:35.820000
 into like a bare bones
 booting state.

0:15:35.820000 --> 0:15:39.140000
 And so we're going to go back and forth
 with this, with sending a little

0:15:39.140000 --> 0:15:41.080000
 bit more power, sensing
 the resistance.

0:15:41.080000 --> 0:15:43.420000
 Oh, now the resistance
 is this much.

0:15:43.420000 --> 0:15:46.620000
 That tells me the power device
 can handle even more.

0:15:46.620000 --> 0:15:48.380000
 And it'll keep going
 back and forth.

0:15:48.380000 --> 0:15:52.000000
 And so by using this electrical energy
 and resistance values and thresholds,

0:15:52.000000 --> 0:15:56.020000
 we'll get to the point where we
 know we've reached our limit.

0:15:56.020000 --> 0:15:58.340000
 Now that device is good to go.

0:15:58.340000 --> 0:16:02.180000
 And so now the PSC knows just
 how much power to deliver.

0:16:02.180000 --> 0:16:05.940000
 Now, in addition to that, so this is
 all part of the power over ethernet

0:16:05.940000 --> 0:16:10.440000
 standard. Whether you're talking about
 802.3 AF or AT, it's all based

0:16:10.440000 --> 0:16:13.560000
 on resistance levels and how
 much power we got back.

0:16:13.560000 --> 0:16:15.020000
 Was there any resistance?

0:16:15.020000 --> 0:16:19.460000
 That's how in the specifications you
 can tell what type of device you're

0:16:19.460000 --> 0:16:23.640000
 connected to and how much
 maximum power it can take.

0:16:23.640000 --> 0:16:27.700000
 But above and beyond that, a lot of
 devices also implement either the

0:16:27.700000 --> 0:16:31.940000
 Cisco Discovery Protocol, if we're
 talking about Cisco devices, or the

0:16:31.940000 --> 0:16:36.460000
 Link Layer Discovery Protocol,
 LLDP for non-Cisco devices.

0:16:36.460000 --> 0:16:38.900000
 And even Cisco devices
 support LLDP.

0:16:38.900000 --> 0:16:44.180000
 Well, if I, by using these resistance
 levels and everything, if I can

0:16:44.180000 --> 0:16:50.240000
 power up that device to the point where
 it can now start sending me CDP

0:16:50.240000 --> 0:16:55.640000
 messages or LLDP messages, that device,
 that power device can now tell

0:16:55.640000 --> 0:16:59.900000
 me the power sourcing equipment even
 more information about itself.

0:16:59.900000 --> 0:17:02.920000
 For example, it might tell me,
 hey, here's the range of power.

0:17:02.920000 --> 0:17:05.860000
 I would prefer you to give me this
 maximum amount, but I can actually

0:17:05.860000 --> 0:17:08.760000
 operate with this minimal
 route right here.

0:17:08.760000 --> 0:17:09.840000
 And we can get that information.

0:17:09.840000 --> 0:17:13.440000
 We can now get information about
 like what type of device is it.

0:17:13.440000 --> 0:17:16.400000
 So we can send it other information
 above and beyond just basic power

0:17:16.400000 --> 0:17:21.020000
 requirements. So let's just finish off
 here by saying, how would we monitor

0:17:21.020000 --> 0:17:23.380000
 this on like Cisco devices?

0:17:23.380000 --> 0:17:27.120000
 So here we have the output of
 show CDP neighbor detail.

0:17:27.120000 --> 0:17:29.280000
 And this is on a switch.

0:17:29.280000 --> 0:17:35.300000
 And we can see here down below,
 it says power drawn 10.25 watts.

0:17:35.300000 --> 0:17:38.580000
 So this represents the maximum
 required power for this.

0:17:38.580000 --> 0:17:40.180000
 This is an IP phone.

0:17:40.180000 --> 0:17:44.400000
 So we can see this is a, it mentions
 up above in platform that this is

0:17:44.400000 --> 0:17:45.740000
 a Cisco IP phone.

0:17:45.740000 --> 0:17:49.380000
 And this Cisco IP phone has said that
 the maximum power will ever need

0:17:49.380000 --> 0:18:08.560000
 is 10.25 watts or
 10,250 milliwatts.

0:18:08.560000 --> 0:18:13.320000
 So we can see that 6.3 watts with
 a reduced screen brightness.

0:18:13.320000 --> 0:18:16.140000
 So this particular phone has
 reduced screen brightness.

0:18:16.140000 --> 0:18:19.860000
 And if it's on that setting, it doesn't
 need to draw nearly as much power.

0:18:19.860000 --> 0:18:22.880000
 So you can see from CDP neighbor that
 we've gotten that information from

0:18:22.880000 --> 0:18:25.700000
 the phone via CDP messages.

0:18:25.700000 --> 0:18:30.800000
 We can also do show power
 in line on the switch.

0:18:30.800000 --> 0:18:33.400000
 This shows us a lot of
 useful information.

0:18:33.400000 --> 0:18:37.840000
 For example, we can see here that module
 one, its power budget, the maximum

0:18:37.840000 --> 0:18:42.380000
 amount of power it has available
 in that module is 420 watts.

0:18:42.380000 --> 0:18:46.060000
 Very little of that has been used right
 now, only 22.2 watts of that has

0:18:46.060000 --> 0:18:51.180000
 been used with most of it still remaining
 for other ports in that module.

0:18:51.180000 --> 0:18:57.500000
 And we can see down here below that
 gigabit 101 is connected to a 7960

0:18:57.500000 --> 0:19:00.700000
 phone which is currently operating under
 minimal power with reduced screen

0:19:00.700000 --> 0:19:04.880000
 brightness. It's operating
 at 6.3 watts.

0:19:04.880000 --> 0:19:09.260000
 And it says on the far right column,
 it's capable of a maximum of 15.4

0:19:09.260000 --> 0:19:16.040000
 watts. So that concludes this video
 on our introduction to power over

0:19:16.040000 --> 0:19:17.840000
 ethernet. Thank you for watching.