WEBVTT

0:00:07.220000 --> 0:00:10.800000
 This video, which is the first video
 in the Cisco Certified Technician

0:00:10.800000 --> 0:00:14.360000
 Series for routing and switching, I'm
 going to go over the topic which

0:00:14.360000 --> 0:00:19.420000
 is in section one called Identifying
 Interfaces on Cisco Devices.

0:00:19.420000 --> 0:00:25.940000
 Once again, my name in case you've forgotten
 is Keith Bogart and I will

0:00:25.940000 --> 0:00:28.540000
 be your instructor for
 this series of videos.

0:00:28.540000 --> 0:00:30.820000
 So in this video, what would
 I like to talk about?

0:00:30.820000 --> 0:00:32.940000
 Well, I'd like to talk
 about several things.

0:00:32.940000 --> 0:00:35.200000
 Number one, what is an interface?

0:00:35.200000 --> 0:00:38.720000
 You probably already know this, but
 just in case, I want to cover all

0:00:38.720000 --> 0:00:42.740000
 the bases here. Where some common types
 of interfaces you would find on

0:00:42.740000 --> 0:00:46.840000
 Cisco routers and switches, how you
 can identify them visually, how you

0:00:46.840000 --> 0:00:50.600000
 can identify them based on knowing
 what kind of cable it connects to,

0:00:50.600000 --> 0:00:54.840000
 and then we'll also talk about
 port numbering conventions.

0:00:54.840000 --> 0:00:59.440000
 So, if you are truly a Cisco Certified
 Technician, you should be able

0:00:59.440000 --> 0:01:01.660000
 to answer a couple of questions.

0:01:01.660000 --> 0:01:04.840000
 For example, if someone gave you this
 question, they said, hey, you need

0:01:04.840000 --> 0:01:10.760000
 to swap out a faulty PA-4T
 on your Cisco 7206 router.

0:01:10.760000 --> 0:01:14.980000
 Given this router right here, given this
 image, which of the letters correctly

0:01:14.980000 --> 0:01:18.620000
 identifies the port adapter
 that needs to be replaced?

0:01:18.620000 --> 0:01:21.900000
 By the time we're done with this video,
 you'll be able to answer that.

0:01:21.900000 --> 0:01:25.360000
 Another type of question that relates
 to understanding and recognizing

0:01:25.360000 --> 0:01:27.500000
 interfaces would be the following.


0:01:27.500000 --> 0:01:32.320000
 You need to swap out the port adapter
 that contains controller T3, 0,

0:01:32.320000 --> 0:01:34.060000
 slash 2, slash 0.

0:01:34.060000 --> 0:01:37.440000
 Once again, given the image below,
 which of the letters identifies the

0:01:37.440000 --> 0:01:41.040000
 correct port adapter that
 needs to be replaced?

0:01:41.040000 --> 0:01:44.300000
 Now, to answer this question requires a
 different skill set than the previous

0:01:44.300000 --> 0:01:47.360000
 question. You'd really need to have
 an understanding of the naming and

0:01:47.360000 --> 0:01:52.440000
 numbering convention of this particular
 model of Cisco router.

0:01:52.440000 --> 0:01:54.640000
 So, what is an interface?

0:01:54.640000 --> 0:01:58.440000
 A very simple basic question, but
 one you definitely need to know.

0:01:58.440000 --> 0:02:00.520000
 An interface is basically
 a connector.

0:02:00.520000 --> 0:02:05.700000
 A connector to a device that provides
 either power or signaling to that

0:02:05.700000 --> 0:02:10.220000
 device. Now, even if you've never touched
 or seen a router or a switch

0:02:10.220000 --> 0:02:13.300000
 before, you're already quite
 familiar with interfaces.

0:02:13.300000 --> 0:02:17.500000
 For example, here's a couple of very
 common interfaces that provide power

0:02:17.500000 --> 0:02:22.740000
 to devices. An interface that provides
 power to your tablet or your laptop.

0:02:22.740000 --> 0:02:26.780000
 So, in this case, electrical energy
 is coming in and via plugging into

0:02:26.780000 --> 0:02:30.400000
 this port, this interface, it's
 powering up the device.

0:02:30.400000 --> 0:02:33.800000
 Another type of interface you're probably
 familiar with are audio and

0:02:33.800000 --> 0:02:35.600000
 video interfaces.

0:02:35.600000 --> 0:02:40.820000
 Here we have a video HDMI port, which
 once again is receiving electrical

0:02:40.820000 --> 0:02:44.040000
 signaling. But this time, the electrical
 signaling is not designed to

0:02:44.040000 --> 0:02:45.340000
 power the device.

0:02:45.340000 --> 0:02:49.180000
 The electrical signaling is formatted
 in such a way that it represents

0:02:49.180000 --> 0:02:51.920000
 video, video signals.

0:02:51.920000 --> 0:02:55.920000
 And then the lower right, we have an audio
 port, which once again is receiving

0:02:55.920000 --> 0:03:00.040000
 electricity, electrical signaling,
 but now the electrical signaling is

0:03:00.040000 --> 0:03:04.220000
 using, is conveying
 audio information.

0:03:04.220000 --> 0:03:05.700000
 So, how are Cisco
 devices different?

0:03:05.700000 --> 0:03:09.900000
 Well, interfaces on Cisco routers and
 switches certainly also can provide

0:03:09.900000 --> 0:03:11.660000
 power or signaling.

0:03:11.660000 --> 0:03:15.480000
 Now, typically, when we're trying to
 identify interfaces on routers and

0:03:15.480000 --> 0:03:19.720000
 switches, we're not really looking for
 interfaces like we just saw, which

0:03:19.720000 --> 0:03:26.340000
 are natively supporting video, like
 HDMI or DVI interfaces, or natively

0:03:26.340000 --> 0:03:30.020000
 supporting audio like we saw
 in those other interfaces.

0:03:30.020000 --> 0:03:33.720000
 Typically, the interfaces we're concerned
 with are either interfaces that

0:03:33.720000 --> 0:03:37.740000
 are receiving power, for example, a
 power adapter could be broken, the

0:03:37.740000 --> 0:03:43.180000
 pins could be bent or damaged, or interfaces
 that carry signaling that

0:03:43.180000 --> 0:03:50.320000
 conveys data. Now, that data might
 actually be audio, video, voice, or

0:03:50.320000 --> 0:03:54.560000
 actual user data like web browsing or
 email, but still, we're typically

0:03:54.560000 --> 0:03:56.860000
 talking about a data interfaces.

0:03:56.860000 --> 0:04:01.060000
 So, as far as identifying power interfaces
 on routers or switches, I probably

0:04:01.060000 --> 0:04:03.740000
 don't have to go into this
 in any great detail.

0:04:03.740000 --> 0:04:07.880000
 Chances are that in your lifetime, you
 have plugged something in to the

0:04:07.880000 --> 0:04:12.740000
 back of a TV or a router you have at
 home or something, and the power

0:04:12.740000 --> 0:04:17.560000
 interface on a Cisco router or switch
 looks pretty much similar to that.

0:04:17.560000 --> 0:04:21.020000
 So, if you were told, hey, this particular
 router or switch, we suspect

0:04:21.020000 --> 0:04:24.680000
 that the power interface
 is damaged in some way.

0:04:24.680000 --> 0:04:28.240000
 Go take a look at it, see if any of
 the pins are broken or damaged or

0:04:28.240000 --> 0:04:29.720000
 snapped off or something.

0:04:29.720000 --> 0:04:32.460000
 Well, you'd be looking for the same kind
 of interface you'd normally expect

0:04:32.460000 --> 0:04:35.880000
 to look for on your laptop
 or on your TV set.

0:04:35.880000 --> 0:04:40.040000
 Basically, a three-pronged or maybe a
 four- or two-pronged interface that

0:04:40.040000 --> 0:04:43.020000
 connects to a power outlet,
 like we see right here.

0:04:43.020000 --> 0:04:45.620000
 Now, where things can get a little
 bit tricky is when you're asked to

0:04:45.620000 --> 0:04:50.940000
 identify a data interface, so that
 you can either inspect it to see if

0:04:50.940000 --> 0:04:54.640000
 there's something wrong with it or
 swap out the module that holds that

0:04:54.640000 --> 0:04:58.660000
 interface. Now, data interfaces on
 Cisco routers and switches come in

0:04:58.660000 --> 0:05:05.460000
 a wide variety of form factors, and
 different criteria define these form

0:05:05.460000 --> 0:05:07.500000
 factors. Now, what do
 I mean by form factor?

0:05:07.500000 --> 0:05:11.700000
 I mean, like, how big or how small it
 is, how many pins it has, whether

0:05:11.700000 --> 0:05:15.680000
 it's a male or a female interface, whether
 it's designed to accept copper

0:05:15.680000 --> 0:05:20.900000
 cabling or fiber optic cabling, wide
 variety of things dictate that.

0:05:20.900000 --> 0:05:24.120000
 For example, is it a LAN
 or a WAN interface?

0:05:24.120000 --> 0:05:27.520000
 The form factor will
 be related to that.

0:05:27.520000 --> 0:05:32.460000
 For example, LAN interfaces typically
 don't have to push as much power

0:05:32.460000 --> 0:05:36.080000
 through that interface because the two
 devices that cable is connecting

0:05:36.080000 --> 0:05:38.060000
 are fairly close to each other.

0:05:38.060000 --> 0:05:41.780000
 Whereas a WAN interface is connecting
 that interface to something that

0:05:41.780000 --> 0:05:46.700000
 might be miles away, so it has to carry
 a lot more energy, either light

0:05:46.700000 --> 0:05:51.220000
 or electrical energy, through that interface
 to get the signal that great

0:05:51.220000 --> 0:05:55.200000
 distance. That will affect the
 form factor of that interface.

0:05:55.200000 --> 0:05:58.980000
 Also, the signaling requirements
 for pins, right?

0:05:58.980000 --> 0:06:02.700000
 So, if we're talking about an interface
 that carries electrical energy,

0:06:02.700000 --> 0:06:06.840000
 pretty much most of those types of interfaces
 have at least two connectors,

0:06:06.840000 --> 0:06:10.820000
 if not more. So, the quantity
 of pins may be different.

0:06:10.820000 --> 0:06:13.960000
 Some protocols say, hey, look, we're
 going to carry all of our data and

0:06:13.960000 --> 0:06:16.800000
 are signaling on one
 electrical current.

0:06:16.800000 --> 0:06:19.360000
 Others say, hey, we're going
 to use multiple pins.

0:06:19.360000 --> 0:06:23.460000
 This pin here is going to be used for
 a separate purpose than this pin

0:06:23.460000 --> 0:06:27.100000
 over here. That's also going
 to dictate the form factor.

0:06:27.100000 --> 0:06:32.260000
 Is that interface carrying light,
 electricity, or radio frequency?

0:06:32.260000 --> 0:06:34.980000
 If it's radio frequency, you're not
 going to see an interface at all.

0:06:34.980000 --> 0:06:38.080000
 It's going to be internal, probably
 on the circuit board, behind a front

0:06:38.080000 --> 0:06:40.200000
 panel of the chassis or something.


0:06:40.200000 --> 0:06:41.880000
 And also space constraints.

0:06:41.880000 --> 0:06:44.880000
 Some interfaces take a lot of space
 because they have to plug in cables

0:06:44.880000 --> 0:06:49.740000
 that have a lot of pins, sometimes
 upwards of 100 pins on one physical

0:06:49.740000 --> 0:06:51.820000
 cable that's plug into a port.

0:06:51.820000 --> 0:06:56.020000
 That can be a fairly wide
 or tall interface.

0:06:56.020000 --> 0:07:00.180000
 Other interfaces are specifically designed
 with space constraints in mind.

0:07:00.180000 --> 0:07:04.360000
 So, you can have a lot of interfaces
 crammed into a very narrow space

0:07:04.360000 --> 0:07:07.420000
 on the line card or
 on the chassis.

0:07:07.420000 --> 0:07:09.940000
 So, where are these
 interfaces located?

0:07:09.940000 --> 0:07:12.540000
 Where would you typically find
 them on a router switch?

0:07:12.540000 --> 0:07:14.960000
 Well, they can go in a couple
 of different places.

0:07:14.960000 --> 0:07:18.780000
 Number one, a lot of interfaces are built
 directly into the chassis itself.

0:07:18.780000 --> 0:07:22.840000
 For example, here you see a couple of
 Ethernet ports that are built directly

0:07:22.840000 --> 0:07:24.580000
 into the chassis.

0:07:24.580000 --> 0:07:26.820000
 Now, what do I mean
 by into the chassis?

0:07:26.820000 --> 0:07:30.320000
 What I mean by that is when you take
 a look at these ports right here,

0:07:30.320000 --> 0:07:37.740000
 these ports, what is holding those
 ports, is not any removable device.

0:07:37.740000 --> 0:07:40.560000
 It's right there on the
 router or switch itself.

0:07:40.560000 --> 0:07:42.560000
 You can't pull those ports out.

0:07:42.560000 --> 0:07:46.640000
 You can't change them for a different
 kind of a port or an interface.

0:07:46.640000 --> 0:07:51.160000
 It's hardwired and built into
 that router or switch itself.

0:07:51.160000 --> 0:07:54.220000
 Other types of interfaces
 can be on removable media.

0:07:54.220000 --> 0:07:55.380000
 This is very popular.

0:07:55.380000 --> 0:07:57.120000
 For example, network modules.

0:07:57.120000 --> 0:08:00.000000
 We see here a network module
 that has interfaces in it.

0:08:00.000000 --> 0:08:04.200000
 And then that network module goes into
 an available module slot on a router

0:08:04.200000 --> 0:08:08.480000
 or a switch. They could also be placed
 on smaller modules that we call

0:08:08.480000 --> 0:08:14.440000
 WAN interface cards or
 Wix or port adapters.

0:08:14.440000 --> 0:08:16.740000
 Or voice Wix, V-Wix.

0:08:16.740000 --> 0:08:19.280000
 So interfaces can be in a
 wide variety of places.

0:08:19.280000 --> 0:08:21.680000
 Sometimes all the interfaces
 are on one side.

0:08:21.680000 --> 0:08:24.740000
 Like for example, this router that we're
 looking at here, all the interfaces

0:08:24.740000 --> 0:08:25.800000
 are on this one side.

0:08:25.800000 --> 0:08:29.600000
 If you turn this router around, you
 might see some LEDs blinking on the

0:08:29.600000 --> 0:08:33.000000
 other side where there wouldn't be any
 place to physically plug in a cable

0:08:33.000000 --> 0:08:36.980000
 anywhere. Other types of routers and
 switches might have interfaces on

0:08:36.980000 --> 0:08:39.000000
 both sides for different purposes.


0:08:39.000000 --> 0:08:42.820000
 So make sure you're aware of what model
 you're looking at because the

0:08:42.820000 --> 0:08:46.840000
 interface might be on the other side
 of the chassis than what you expected

0:08:46.840000 --> 0:08:51.340000
 it to be. Now how can we
 identify interfaces?

0:08:51.340000 --> 0:08:52.860000
 Well, there's several
 different ways.

0:08:52.860000 --> 0:08:55.120000
 Number one, visually, of course.

0:08:55.120000 --> 0:08:58.960000
 If you have the luxury of being right
 there in front of the router or

0:08:58.960000 --> 0:09:01.780000
 the switch, you can certainly
 look at it.

0:09:01.780000 --> 0:09:06.680000
 And if you know in advance what the
 interface is supposed to look like,

0:09:06.680000 --> 0:09:10.360000
 that can help you find it
 on the router switch.

0:09:10.360000 --> 0:09:14.580000
 Or conversely, you can rule out what
 it definitely won't look like.

0:09:14.580000 --> 0:09:17.900000
 For example, once you know that you're
 looking for an Ethernet interface,

0:09:17.900000 --> 0:09:21.440000
 well, if you see a router that has
 a whole bunch of serial interfaces,

0:09:21.440000 --> 0:09:24.040000
 you can say, look, I know those
 are serial interfaces.

0:09:24.040000 --> 0:09:28.280000
 I might not know specifically what
 kind of connector is connecting to

0:09:28.280000 --> 0:09:31.720000
 those serial interfaces, but just by
 looking at them, I can tell with

0:09:31.720000 --> 0:09:36.540000
 my eyeballs, those are not Ethernet interfaces,
 and that's what I'm looking

0:09:36.540000 --> 0:09:38.340000
 for, is an Ethernet interface.

0:09:38.340000 --> 0:09:43.460000
 Certainly also, all Cisco modules have
 the printed part number on the

0:09:43.460000 --> 0:09:47.320000
 module itself. Now depending on how
 old the module is or how beat up it

0:09:47.320000 --> 0:09:51.300000
 is, that part number might be scratched
 off or smudged or something.

0:09:51.300000 --> 0:09:54.980000
 So you can't always rely on the fact
 that it might have a very clearly

0:09:54.980000 --> 0:09:58.440000
 visible part number, but
 hopefully it will.

0:09:58.440000 --> 0:10:01.600000
 Also, platform numbering
 conventions.

0:10:01.600000 --> 0:10:05.800000
 For example, if somebody says, hey,
 you need to take out the module that

0:10:05.800000 --> 0:10:10.180000
 contains the fast Ethernet interface,
 zero slash five slash zero.

0:10:10.180000 --> 0:10:15.700000
 Well, if you go to a device, it might
 have a whole slew of modules, all

0:10:15.700000 --> 0:10:18.160000
 of which have fast Ethernet
 interfaces.

0:10:18.160000 --> 0:10:22.980000
 So in this particular case, you have
 to know what zero slash five slash

0:10:22.980000 --> 0:10:27.880000
 zero actually means, so you can identify
 the particular port or module

0:10:27.880000 --> 0:10:31.960000
 that contains that interface
 you're looking for.

0:10:31.960000 --> 0:10:35.280000
 And then of course, you have to understand
 Cisco part numbers as well.

0:10:35.280000 --> 0:10:38.320000
 Somebody could say, for example, in that
 first objective we had, actually

0:10:38.320000 --> 0:10:41.060000
 I think it was the second objective,
 the second objective said, hey, look

0:10:41.060000 --> 0:10:46.820000
 for a PA-4T, we need you to replace that
 and swap it out for a replacement.

0:10:46.820000 --> 0:10:52.080000
 Well, if you don't know what a PA-4T
 is and you're looking at a row that's

0:10:52.080000 --> 0:10:56.320000
 got six or eight or ten modules in
 it, how would you know which one to

0:10:56.320000 --> 0:11:00.200000
 pull out? So that would be a skill
 set that a CCT would need to have,

0:11:00.200000 --> 0:11:03.740000
 is to be able to figure out what that
 module is, so they pull out the

0:11:03.740000 --> 0:11:07.820000
 correct one. So let's look at some
 common interface types that you're

0:11:07.820000 --> 0:11:11.120000
 going to see, so you might be able to
 recognize these, as well as identify

0:11:11.120000 --> 0:11:13.540000
 them within the CCT exam itself.

0:11:13.540000 --> 0:11:16.440000
 So we'll start with probably one of
 the most popular ones, which is the

0:11:16.440000 --> 0:11:22.160000
 RJ45. So RJ45, RJ just stands
 for Register Jack.

0:11:22.160000 --> 0:11:25.300000
 And you can see here, you've probably
 seen this a lot, this is typically

0:11:25.300000 --> 0:11:29.180000
 used in Ethernet interfaces.

0:11:29.180000 --> 0:11:33.040000
 For example, we see here a switch with
 a whole bunch of Ethernet interfaces,

0:11:33.040000 --> 0:11:39.560000
 but please be careful, because RJ45 is
 not always used for Ethernet, don't

0:11:39.560000 --> 0:11:44.900000
 assume that an RJ45 connector that you're
 looking at is supposed to connect

0:11:44.900000 --> 0:11:45.620000
 to an Ethernet cable.

0:11:45.620000 --> 0:11:49.560000
 For example, here's an RJ45 port that's
 connecting to a completely different

0:11:49.560000 --> 0:11:56.020000
 protocol that uses completely different
 power requirements called HDSL.

0:11:56.020000 --> 0:11:59.540000
 Here's another RJ45 jack that in this
 case is connecting to a console

0:11:59.540000 --> 0:12:02.080000
 port or an auxiliary port.

0:12:02.080000 --> 0:12:07.040000
 Once again, the cables and the jacks look
 the same, but the power requirements

0:12:07.040000 --> 0:12:11.180000
 and what those interfaces are trying
 to accomplish is very different from

0:12:11.180000 --> 0:12:15.740000
 each other. So the takeaway here is
 you should recognize what an RJ45

0:12:15.740000 --> 0:12:21.140000
 jack looks like, but don't assume the
 type of protocol that is running

0:12:21.140000 --> 0:12:25.780000
 across that cable, just based
 on the jack itself.

0:12:25.780000 --> 0:12:29.880000
 Another type of common connector is called
 a G-BIC or a Gigabit Interface

0:12:29.880000 --> 0:12:35.220000
 connector. These were initially designed
 to allow for fiber optic connections.

0:12:35.220000 --> 0:12:39.240000
 Nowadays, G-BIC support a wide variety
 of combinations that are also used

0:12:39.240000 --> 0:12:41.920000
 in WAN interfaces as
 well as Ethernet.

0:12:41.920000 --> 0:12:47.040000
 So for example, the G-BIC is in the upper
 left here, and the G-BIC itself

0:12:47.040000 --> 0:12:49.080000
 would go into an available slot.

0:12:49.080000 --> 0:12:53.700000
 So for example, here we see a line card
 that's designed just for a variety

0:12:53.700000 --> 0:12:57.520000
 of G-BICs. It looks like we've got
 about 16 or so G-BICs that will fit

0:12:57.520000 --> 0:12:59.220000
 into this line card here.

0:12:59.220000 --> 0:13:04.740000
 Down here we have a switch that is
 comprised mostly of RJ45 jacks, but

0:13:04.740000 --> 0:13:09.220000
 it has a couple of up links in which
 you can put in some G-BICs.

0:13:09.220000 --> 0:13:13.620000
 So a G-BIC would go into that
 type of slot right there.

0:13:13.620000 --> 0:13:17.660000
 So historically G-BICs
 came out after RJ45.

0:13:17.660000 --> 0:13:23.000000
 RJ45 was used for a long time, and
 then when fiber optic Ethernet came

0:13:23.000000 --> 0:13:27.620000
 out, there were several variants or
 flavors of fiber optic Ethernet, and

0:13:27.620000 --> 0:13:31.140000
 I'll get into that when we get
 into the cabling section next.

0:13:31.140000 --> 0:13:34.340000
 There was some fiber optic Ethernet that
 was designed for short distances,

0:13:34.340000 --> 0:13:38.800000
 medium, long distances, some fiber optic
 Ethernet that was designed where

0:13:38.800000 --> 0:13:43.300000
 the light was supposed to be conveyed
 via simple and inexpensive LEDs,

0:13:43.300000 --> 0:13:49.180000
 light emitting diodes, or very high
 quality expensive lasers would emit

0:13:49.180000 --> 0:13:51.300000
 the light source.

0:13:51.300000 --> 0:13:54.940000
 So somebody had the bright idea, hey,
 why don't we create these removable

0:13:54.940000 --> 0:14:00.680000
 connectors called G-BICs, and then a person
 can just buy a module or router

0:14:00.680000 --> 0:14:04.560000
 or switch that has an empty slot, and
 they can put in the G-BIC for whatever

0:14:04.560000 --> 0:14:08.560000
 they want. If they want to support the
 high powered laser, they can put

0:14:08.560000 --> 0:14:10.200000
 in a G-BIC that supports that.

0:14:10.200000 --> 0:14:13.980000
 If they want to interface as the lower
 powered LEDs, they can put in a

0:14:13.980000 --> 0:14:15.640000
 G-BIC that supports that.

0:14:15.640000 --> 0:14:17.600000
 Now let's move forward in time.

0:14:17.600000 --> 0:14:22.120000
 Eventually somebody said, well, these
 G-BICs are fairly wide, and there's

0:14:22.120000 --> 0:14:25.960000
 only a certain amount of them
 that will fit onto a chassis.

0:14:25.960000 --> 0:14:29.480000
 Wouldn't it be nice if we could create
 another type of adapter that's

0:14:29.480000 --> 0:14:32.880000
 also removable that you can swap with
 different things that will always

0:14:32.880000 --> 0:14:39.060000
 fit into a common slot or a common
 port on your router or switch, but

0:14:39.060000 --> 0:14:42.660000
 it's smaller, so you could fit
 more of them into your device.

0:14:42.660000 --> 0:14:46.260000
 And this is where something called
 the SFP came into play, which is a

0:14:46.260000 --> 0:14:49.400000
 small form factor pluggable.

0:14:49.400000 --> 0:14:54.580000
 So here we can see an example of an
 SFP that supports two fiber optic

0:14:54.580000 --> 0:14:58.820000
 cables. So one of the cables would
 be for your transmitting light that

0:14:58.820000 --> 0:15:02.920000
 you're transmitting out, another cable
 B for receiving incoming light

0:15:02.920000 --> 0:15:08.780000
 pulses. And then that SFP would
 stick into an available slot.

0:15:08.780000 --> 0:15:14.120000
 And because SFPs are smaller in nature,
 there's more SFP ports you can

0:15:14.120000 --> 0:15:19.620000
 put into the same space as
 you would put in G-BICs.

0:15:19.620000 --> 0:15:26.140000
 Now switches in addition to having
 RJ45 and or G-BICs or SFPs may also

0:15:26.140000 --> 0:15:28.920000
 have some other special
 purpose interfaces.

0:15:28.920000 --> 0:15:32.240000
 You need to be aware of these and
 be able to identify these as well.

0:15:32.240000 --> 0:15:36.780000
 For example, the interface we see here
 is what's called an RPS interface.

0:15:36.780000 --> 0:15:40.020000
 This stands for redundant
 power supply.

0:15:40.020000 --> 0:15:43.660000
 We know that these switches have internal
 power supplies built into them,

0:15:43.660000 --> 0:15:46.900000
 and your power cable would go right
 here into your power jack.

0:15:46.900000 --> 0:15:51.060000
 But what happens if your internal
 power supply fails?

0:15:51.060000 --> 0:15:55.200000
 It does happen. Well, this is where
 having your redundant power supply

0:15:55.200000 --> 0:15:56.240000
 would come into play.

0:15:56.240000 --> 0:16:00.400000
 So if you have a switch that's got an
 RPS interface, you can connect that

0:16:00.400000 --> 0:16:04.960000
 to a special cable, and the other end
 of that cable will connect into

0:16:04.960000 --> 0:16:09.960000
 an redundant power supply
 like an RPS 2300.

0:16:09.960000 --> 0:16:15.400000
 The RPS 2300 here is an example of a
 single device that can monitor the

0:16:15.400000 --> 0:16:18.760000
 power state of up to six switches.


0:16:18.760000 --> 0:16:22.960000
 And if up to two of those switches
 fail, if the internal power supply

0:16:22.960000 --> 0:16:28.100000
 fails, this guy here on the right can
 provide power, keep those switches

0:16:28.100000 --> 0:16:32.500000
 going, so you don't have a power outage
 right in the middle of a busy

0:16:32.500000 --> 0:16:37.960000
 workday. Another type of special purpose
 interface is called a stacking

0:16:37.960000 --> 0:16:43.800000
 interface. So here we have an example
 of a cup of a 3750, and if you buy

0:16:43.800000 --> 0:16:48.460000
 a certain stack cable and connect it
 to those stack interfaces, you can

0:16:48.460000 --> 0:16:52.720000
 then have what's called a switch stack,
 where you have multiple 3750s,

0:16:52.720000 --> 0:16:58.900000
 cable together, and they operate and
 can be managed as one single unit.

0:16:58.900000 --> 0:17:02.220000
 So this is by using certain type of
 interface called a stack interface,

0:17:02.220000 --> 0:17:06.820000
 which connects the back plane
 of these devices together.

0:17:06.820000 --> 0:17:10.260000
 Now other types of switches also have
 stack interfaces that look a little

0:17:10.260000 --> 0:17:12.800000
 bit differently and use
 different cables.

0:17:12.800000 --> 0:17:17.580000
 For example, here's the 2960, the KEL
 is 2960 uses a special module called

0:17:17.580000 --> 0:17:19.520000
 a flex stack module.

0:17:19.520000 --> 0:17:23.960000
 The purpose is the same as what we
 just saw in the 3750, but the cable

0:17:23.960000 --> 0:17:25.580000
 it uses is different.

0:17:25.580000 --> 0:17:29.480000
 You can see right there it's got completely
 different ends or tips to

0:17:29.480000 --> 0:17:32.560000
 it, and those connectors
 do the same purpose.

0:17:32.560000 --> 0:17:36.240000
 You can stack several
 2960s together.

0:17:36.240000 --> 0:17:42.180000
 So that takes care of our LAN interfaces,
 our RJ45s, our fiber optic interfaces

0:17:42.180000 --> 0:17:47.340000
 of our like G-Bix and SFPs, as well as
 some special purpose switch interfaces

0:17:47.340000 --> 0:17:52.240000
 for stacking. Now let's take a look
 at our LAN interfaces, our serial

0:17:52.240000 --> 0:17:56.680000
 interfaces. So first of all, why
 do we need a serial interface?

0:17:56.680000 --> 0:17:59.600000
 Well, what does serial mean?

0:17:59.600000 --> 0:18:03.660000
 In the context of data communication,
 serial simply means I'm putting

0:18:03.660000 --> 0:18:07.060000
 one bit after the other
 onto the wire.

0:18:07.060000 --> 0:18:11.840000
 So if I want to transmit a bunch of bits
 to you, I send you one at a time.

0:18:11.840000 --> 0:18:15.720000
 That is simply what we mean
 by serial communications.

0:18:15.720000 --> 0:18:25.920000
 Now if we think about that, Ethernet
 also does serial communications,

0:18:25.920000 --> 0:18:28.120000
 right? So as we look at our RJ45 jack,
 there's several pins there on the

0:18:28.120000 --> 0:18:33.020000
 RJ45 jack. Ethernet at minimum needs four
 of those pins, two for transmitting

0:18:33.020000 --> 0:18:35.120000
 and two for receiving.

0:18:35.120000 --> 0:18:37.800000
 But let's just focus in, for example,
 on the two pins are transmitting

0:18:37.800000 --> 0:18:39.780000
 on your RJ45 jack.

0:18:39.780000 --> 0:18:44.780000
 One of those pins is for a high voltage,
 one of those pins is for a lower

0:18:44.780000 --> 0:18:47.880000
 voltage. So when you're transmitting a
 one, you'll use one pin, when you're

0:18:47.880000 --> 0:18:53.240000
 transmitting a zero, you'll use another
 pin, but still one bit after the

0:18:53.240000 --> 0:18:57.560000
 other. So why do we need these special
 types of cables and interfaces

0:18:57.560000 --> 0:19:03.600000
 called serial, which also transmit electricity
 in bits one bit after the

0:19:03.600000 --> 0:19:05.420000
 other in serial communication?

0:19:05.420000 --> 0:19:08.160000
 Well, here's the main distinction,
 the main differentiator.

0:19:08.160000 --> 0:19:14.420000
 Historically, Ethernet capped out at a
 maximum distance of about 100 meters.

0:19:14.420000 --> 0:19:17.840000
 So the maximum distance you could have
 between any two endpoints of your

0:19:17.840000 --> 0:19:20.020000
 Ethernet cable was 100 meters.

0:19:20.020000 --> 0:19:24.400000
 So what if you wanted a single line
 to run a protocol that was longer

0:19:24.400000 --> 0:19:26.260000
 than this in distance?

0:19:26.260000 --> 0:19:29.180000
 Well, then you needed something
 other than Ethernet.

0:19:29.180000 --> 0:19:32.800000
 Ethernet wouldn't handle that if I wanted
 to transmit my electricity maybe

0:19:32.800000 --> 0:19:36.820000
 500 meters or maybe a thousand meters
 or maybe even five or ten miles

0:19:36.820000 --> 0:19:39.280000
 from one interface to the other.

0:19:39.280000 --> 0:19:44.540000
 This is where WAN protocols or wide
 area networking came into play.

0:19:44.540000 --> 0:19:48.360000
 So serial interfaces
 came out in that day.

0:19:48.360000 --> 0:19:52.180000
 It's used typically for WAN connectivity
 when protocols other than Ethernet

0:19:52.180000 --> 0:19:57.500000
 are needed. And serial interfaces are
 primarily designed for time division

0:19:57.500000 --> 0:20:01.260000
 multiplexing. What is that?

0:20:01.260000 --> 0:20:02.900000
 Well, think about Ethernet.

0:20:02.900000 --> 0:20:05.420000
 Once again, if you're working in the
 field of networking, you have to

0:20:05.420000 --> 0:20:09.300000
 know what Ethernet is and
 how Ethernet works.

0:20:09.300000 --> 0:20:12.880000
 Historically, the way Ethernet works
 is that you can have a whole bunch

0:20:12.880000 --> 0:20:18.240000
 of devices all sharing a common Ethernet
 cable, which means that only

0:20:18.240000 --> 0:20:21.360000
 one device can talk at a time.

0:20:21.360000 --> 0:20:23.980000
 That's one of the cardinal
 rules of Ethernet.

0:20:23.980000 --> 0:20:27.220000
 If we're all sharing the same Ethernet
 cable, that means when I'm talking,

0:20:27.220000 --> 0:20:31.100000
 that means I am sending out electrical
 energy on that cable, nobody else

0:20:31.100000 --> 0:20:32.480000
 can talk but me.

0:20:32.480000 --> 0:20:36.120000
 And then when I'm done,
 somebody else can talk.

0:20:36.120000 --> 0:20:39.740000
 So in theory, every
 device can talk.

0:20:39.740000 --> 0:20:42.240000
 They'll have some opportunity
 to talk.

0:20:42.240000 --> 0:20:47.640000
 But if I have one device that's more
 chatty than others, that device is

0:20:47.640000 --> 0:20:50.100000
 going to get that cable
 more frequently.

0:20:50.100000 --> 0:20:54.140000
 So every other device is not going to
 get a fair share of the bandwidth

0:20:54.140000 --> 0:20:58.800000
 because that one device that's chatty
 is getting to speak more frequently.

0:20:58.800000 --> 0:21:02.440000
 Time division multiplexing
 is one way around that.

0:21:02.440000 --> 0:21:06.380000
 Time division multiplexing says, look,
 we still have a situation where

0:21:06.380000 --> 0:21:11.680000
 we have one physical media, in this
 case, a serial cable, a serial link,

0:21:11.680000 --> 0:21:14.180000
 and the serial link is
 able to carry bits.

0:21:14.180000 --> 0:21:18.580000
 Some of those bits are from Tom, some
 are from Sue, some are from Sally.

0:21:18.580000 --> 0:21:21.800000
 But unlike Ethernet, they would say,
 hey, Tom, if you're really chatty,

0:21:21.800000 --> 0:21:25.360000
 if you're talking right now, most of
 the bits going across a serial cable

0:21:25.360000 --> 0:21:26.820000
 will be from you.

0:21:26.820000 --> 0:21:30.900000
 Time division multiplexing says, hey,
 look, we're going to take each user

0:21:30.900000 --> 0:21:35.720000
 that's connected to this cable and
 give them a certain dedicated slot

0:21:35.720000 --> 0:21:42.100000
 of time. In other words, during one
 second, the first quarter, the first

0:21:42.100000 --> 0:21:46.040000
 25% of every single second
 will be for Tom.

0:21:46.040000 --> 0:21:49.980000
 The second quarter of every single
 second will be for Sally.

0:21:49.980000 --> 0:21:51.660000
 The third quarter will be for Sue.


0:21:51.660000 --> 0:21:57.880000
 So that way, whether Tom is talking
 or not, he only has access to his

0:21:57.880000 --> 0:22:00.460000
 particular time slot
 and that's it.

0:22:00.460000 --> 0:22:06.060000
 Everybody has a reserve time slot, so
 we know when data is going to fit

0:22:06.060000 --> 0:22:07.920000
 into those time slots.

0:22:07.920000 --> 0:22:12.320000
 So serial cables were primarily designed
 for those protocols that understood

0:22:12.320000 --> 0:22:15.240000
 time division multiplexing.

0:22:15.240000 --> 0:22:19.080000
 Now, serial cables provide for
 lots of different form factors.

0:22:19.080000 --> 0:22:22.480000
 If I just say, hey, locate the serial
 cable on my router and pull it out,

0:22:22.480000 --> 0:22:25.320000
 that's not going to give you enough
 information because there's a lot

0:22:25.320000 --> 0:22:27.260000
 of different serial connectors.

0:22:27.260000 --> 0:22:30.940000
 Let me show you three of the most common
 form factors that you'll find

0:22:30.940000 --> 0:22:35.840000
 on Cisco devices if you're asked
 to identify a serial connector.

0:22:35.840000 --> 0:22:41.080000
 By far, the most common form factor
 is what's called the DB60 or 5-in

0:22:41.080000 --> 0:22:43.660000
-1, and this is what it
 looks like right here.

0:22:43.660000 --> 0:22:48.880000
 So this is what most serial cables
 are plugged into, is a DB60 jack.

0:22:48.880000 --> 0:22:51.980000
 Another kind is called
 a 68-pin connector.

0:22:51.980000 --> 0:22:54.260000
 You can see it's narrower,
 but it's longer.

0:22:54.260000 --> 0:22:59.020000
 Another kind is called a Cisco smart
 serial, completely different form

0:22:59.020000 --> 0:23:01.700000
 factor that connects to a completely
 different cable.

0:23:01.700000 --> 0:23:07.560000
 So all three of these are technically
 what we call serial interfaces,

0:23:07.560000 --> 0:23:10.560000
 but you can see their form factors
 are vastly different.

0:23:10.560000 --> 0:23:13.860000
 And there's even more than this, but
 these are the three most common that

0:23:13.860000 --> 0:23:16.720000
 you'll find on Cisco devices.

0:23:16.720000 --> 0:23:22.560000
 Now, in addition to Ethernet interfaces
 and serial interfaces, there are

0:23:22.560000 --> 0:23:26.100000
 some other specialized interfaces I
 just want to call your attention to.

0:23:26.100000 --> 0:23:27.960000
 Take a look at these.

0:23:27.960000 --> 0:23:30.260000
 These are RJ45 jacks.

0:23:30.260000 --> 0:23:32.420000
 You might initially think,
 oh, that's Ethernet.

0:23:32.420000 --> 0:23:37.120000
 Not so quick. These interfaces are specifically
 for voice communications.

0:23:37.120000 --> 0:23:41.000000
 Notice that one of them is located
 on what's called an FXX interface.

0:23:41.000000 --> 0:23:45.060000
 The other's got an FXO interface.

0:23:45.060000 --> 0:23:50.540000
 FXX ports connect directly
 to regular analog phones.

0:23:50.540000 --> 0:23:53.320000
 So, you know, if you've got a regular
 analog phone that you've got plugged

0:23:53.320000 --> 0:23:56.440000
 into your wall and you pick up that
 phone and you'd die to your mom or

0:23:56.440000 --> 0:24:02.000000
 your boss, it would plug directly
 into an FXS interface.

0:24:02.000000 --> 0:24:07.540000
 FXO ports are used to connect to PBX or
 key systems to provide off-premises

0:24:07.540000 --> 0:24:12.080000
 connections to the public switched
 telephone network.

0:24:12.080000 --> 0:24:16.900000
 And then lastly, some other interfaces
 are coaxial interfaces.

0:24:16.900000 --> 0:24:19.840000
 There's a lot of protocols that make
 use of coaxial interfaces, just like

0:24:19.840000 --> 0:24:24.320000
 the coaxial cable you have going
 into your cable TV set at home.

0:24:24.320000 --> 0:24:29.380000
 For example, we see the on the Cisco
 7300, the 6 port clear channel T3

0:24:29.380000 --> 0:24:35.860000
 line card on the left, and we have
 the 1 port ATM DS3 port adapter on

0:24:35.860000 --> 0:24:40.060000
 the right. Now, at the CCT level, you
 don't need to know what some of

0:24:40.060000 --> 0:24:44.300000
 these more advanced terms like
 T3 and A3 are for ATM.

0:24:44.300000 --> 0:24:53.860000
 You don't need to know that.

0:24:53.860000 --> 0:24:58.220000
 The module you might be asked to replace
 or look for might have coaxial

0:24:58.220000 --> 0:24:59.960000
 cable interfaces.

0:24:59.960000 --> 0:25:05.000000
 And you can see here on just the 7200
 series, there are lots of different

0:25:05.000000 --> 0:25:09.540000
 modules, lots of different interfaces
 that carry different things.

0:25:09.540000 --> 0:25:11.100000
 So, let's go back to
 our first objective.

0:25:11.100000 --> 0:25:15.860000
 Our first question was you need to swap
 out a faulty PA4T on your Cisco

0:25:15.860000 --> 0:25:20.060000
 router. Given the image below, which
 of these letters identifies a correct

0:25:20.060000 --> 0:25:21.740000
 port adapter that needs
 to be replaced?

0:25:21.740000 --> 0:25:25.000000
 So, the first thing you would need to
 do to answer this question is you

0:25:25.000000 --> 0:25:28.780000
 would probably want to
 Google the term PA-4T.

0:25:28.780000 --> 0:25:32.440000
 So, let's go ahead and do that.

0:25:32.440000 --> 0:25:37.200000
 All right, so I'm going to go
 ahead and Google PA-4T here.

0:25:37.200000 --> 0:25:40.300000
 Let's just bring this over
 here so we can see it.

0:25:40.300000 --> 0:25:48.600000
 I'll say Cisco PA-4T.

0:25:48.600000 --> 0:25:52.000000
 Now, we can see right here, right away
 we can see, ah, this is clearly

0:25:52.000000 --> 0:25:54.000000
 a serial adapter.

0:25:54.000000 --> 0:25:55.840000
 This is a serial port.

0:25:55.840000 --> 0:25:57.820000
 So, right there, what do we know?

0:25:57.820000 --> 0:26:03.480000
 We know that serial interfaces never
 come in the form factor of an RJ45.

0:26:03.480000 --> 0:26:06.580000
 So, if I'm looking at my device, once
 again, let's go back to our picture

0:26:06.580000 --> 0:26:12.840000
 right here. Most of the interfaces
 on this router are RJ45 interfaces,

0:26:12.840000 --> 0:26:15.780000
 and that is not what
 I'm looking for.

0:26:15.780000 --> 0:26:19.480000
 So, we can rule out
 a lot of this stuff.

0:26:19.480000 --> 0:26:23.800000
 So, we know that the RJ45s are definitely
 out of the equation, so we're

0:26:23.800000 --> 0:26:25.780000
 looking for serial ports.

0:26:25.780000 --> 0:26:29.980000
 Now, if we continue to go back here,
 probably the most important thing

0:26:29.980000 --> 0:26:31.940000
 to do would just be
 to click on images.

0:26:31.940000 --> 0:26:35.440000
 Let's get an image of what
 a PA-4T looks like.

0:26:35.440000 --> 0:26:37.380000
 And here we can see.

0:26:37.380000 --> 0:26:42.300000
 It has four interfaces on it,
 which are those special DB60s.

0:26:42.300000 --> 0:26:48.100000
 So, based on that, the correct
 answer would be A.

0:26:48.100000 --> 0:26:52.840000
 A here would be the PA-4T that
 you would need to swap out.

0:26:52.840000 --> 0:26:56.860000
 Okay, what about answering
 this question?

0:26:56.860000 --> 0:26:59.380000
 Port numbering conventions.

0:26:59.380000 --> 0:27:04.660000
 So, how do I find out if, for example,
 I'm asked to replace, if someone

0:27:04.660000 --> 0:27:08.700000
 says, hey, look, we're having a problem
 with port 0 slash 7 slash 5.

0:27:08.700000 --> 0:27:11.020000
 Can you take a look at it for us?

0:27:11.020000 --> 0:27:17.320000
 Well, how would I know where on my
 router is port 0 slash 7 slash 5?

0:27:17.320000 --> 0:27:20.660000
 Because every router has a different
 numbering convention, it seems.

0:27:20.660000 --> 0:27:24.880000
 So, step number one would be to identify
 the chassis or model that you're

0:27:24.880000 --> 0:27:29.400000
 looking at. Somewhere on the chassis,
 there should be a stamp or a sticker

0:27:29.400000 --> 0:27:34.500000
 or label that indicates what specific
 kind of router or switch this is

0:27:34.500000 --> 0:27:35.760000
 that you're looking at.

0:27:35.760000 --> 0:27:39.920000
 For example, this is an example of
 a Cisco 7206 that we're looking at

0:27:39.920000 --> 0:27:45.220000
 right here. Once you've identified that,
 then locate the hardware installation

0:27:45.220000 --> 0:27:47.840000
 guide on Cisco.com.

0:27:47.840000 --> 0:27:49.960000
 I like to use Google once again.

0:27:49.960000 --> 0:27:53.020000
 For example, if I can
 go back to here.

0:27:53.020000 --> 0:28:03.280000
 If I say, okay, now I know it's a Cisco
 7206, Cisco 7206 Hardware Installation

0:28:03.280000 --> 0:28:08.180000
 Guide. And there we go, installation
 and configuration guide.

0:28:08.180000 --> 0:28:10.460000
 That's probably what you're
 going to be looking for.

0:28:10.460000 --> 0:28:16.000000
 So once you find that, then open up
 that guide and do a quick search on

0:28:16.000000 --> 0:28:18.100000
 the keyword of numbering.

0:28:18.100000 --> 0:28:20.660000
 And that will bring you to some
 sort of diagram like this one.

0:28:20.660000 --> 0:28:24.000000
 This actually came from the hardware
 installation guide of the 7206.

0:28:24.000000 --> 0:28:28.000000
 And it shows us, ah, okay, on this platform,
 the module on the very bottom

0:28:28.000000 --> 0:28:30.220000
 is port adapter slot 0.

0:28:30.220000 --> 0:28:35.300000
 And then we have 1,
 2, 3, 4, 5 and 6.

0:28:35.300000 --> 0:28:40.060000
 So based on that, going to our second
 objective, was we needed swap out

0:28:40.060000 --> 0:28:45.420000
 the port adapter that contained
 controller T30 slash 2 slash 0.

0:28:45.420000 --> 0:28:49.940000
 Well, once we've identified this as a
 7206, we know that this bottom module

0:28:49.940000 --> 0:28:53.400000
 is, and we know if we look at the hardware
 installation guide, we know

0:28:53.400000 --> 0:28:57.760000
 that the number in the middle here,
 in this case the 2, references the

0:28:57.760000 --> 0:29:03.220000
 slot number where the module or the port
 adapter is sitting in or is seated.

0:29:03.220000 --> 0:29:06.900000
 So if we're looking for the module
 that's in slot 2, well, now we know

0:29:06.900000 --> 0:29:09.160000
 that this bottom slot is slot 0.

0:29:09.160000 --> 0:29:14.620000
 The one on the left is slot
 1, so slot 2 is answer G.

0:29:14.620000 --> 0:29:18.900000
 So even though we might not know what that
 port adapter is or what's designed

0:29:18.900000 --> 0:29:25.600000
 to do, just the fact that 0 slash 2
 slash 0, the 2 identifies that G is

0:29:25.600000 --> 0:29:26.640000
 the correct answer.

