WEBVTT

0:00:07.220000 --> 0:00:11.180000
 In this video, I'm going to cover another
 topic from section one of the

0:00:11.180000 --> 0:00:16.260000
 routing and switching CCT exam, which
 is identify the cabling on Cisco

0:00:16.260000 --> 0:00:21.980000
 equipment. Once again, my name is Keith
 Bogart, and I will be your instructor

0:00:21.980000 --> 0:00:23.660000
 for this video session.

0:00:23.660000 --> 0:00:25.700000
 So what are we going to talk
 about in this session?

0:00:25.700000 --> 0:00:29.380000
 Well, I'm going to talk about
 three major things.

0:00:29.380000 --> 0:00:33.620000
 Under what circumstances would you need
 to identify the cabling on Cisco

0:00:33.620000 --> 0:00:38.080000
 equipment? What is some common network
 cabling that you will run across?

0:00:38.080000 --> 0:00:42.100000
 And what are some of the major differences
 between copper and fiber optic

0:00:42.100000 --> 0:00:47.160000
 cables? So under what circumstances
 would you need to identify cables?

0:00:47.160000 --> 0:00:49.060000
 Well, there's several
 different situations.

0:00:49.060000 --> 0:00:52.760000
 Number one, maybe you're asked to go
 find a replacement ethernet cable

0:00:52.760000 --> 0:00:56.420000
 or something. Well, you would need
 to know how to accomplish this.

0:00:56.420000 --> 0:00:59.180000
 There's more than one kind of ethernet
 cable and you need to be aware

0:00:59.180000 --> 0:01:03.120000
 of that. Or alternatively,
 serial cables.

0:01:03.120000 --> 0:01:05.120000
 You might have to go
 find a serial cable.

0:01:05.120000 --> 0:01:08.460000
 Serial cables come in lots
 of different form factors.

0:01:08.460000 --> 0:01:12.460000
 You need to know which one you want if
 you're asked to replace or purchase

0:01:12.460000 --> 0:01:17.780000
 one. Or there's always the option of
 replacing or purchasing some new

0:01:17.780000 --> 0:01:19.160000
 fiber optic cable.

0:01:19.160000 --> 0:01:23.080000
 Do you know which one is appropriate
 for the port adapter or interface

0:01:23.080000 --> 0:01:24.520000
 that you're connecting to?

0:01:24.520000 --> 0:01:27.500000
 These are all questions that hopefully
 you'll be able to answer by the

0:01:27.500000 --> 0:01:29.220000
 time you're done with
 this section.

0:01:29.220000 --> 0:01:32.740000
 So let's start at a very high level
 when it comes to cabling.

0:01:32.740000 --> 0:01:36.780000
 So cabling in general comes
 in two main categories.

0:01:36.780000 --> 0:01:41.680000
 You've got copper cabling and you've
 got fiber optic cabling.

0:01:41.680000 --> 0:01:45.440000
 So the shape of the receptacle that
 that cable is going to plug into is

0:01:45.440000 --> 0:01:49.080000
 going to give you a pretty good clue
 as to whether or not that interface

0:01:49.080000 --> 0:01:54.820000
 requires a fiber or a copper cable
 is going to plug into it.

0:01:54.820000 --> 0:01:57.640000
 For example, here we see RJ45.

0:01:57.640000 --> 0:02:02.300000
 RJ45 jacks always accept
 copper cables.

0:02:02.300000 --> 0:02:08.100000
 Here we see from the previous video the
 Cisco DB60 or 5-in-1 serial interface

0:02:08.100000 --> 0:02:11.000000
 also accepts copper cable.

0:02:11.000000 --> 0:02:15.100000
 As do we see here we see some coaxial
 interfaces that once again, accepts

0:02:15.100000 --> 0:02:21.300000
 copper cable. Now your typical G-Bix
 and your SFPs, those accept your

0:02:21.300000 --> 0:02:22.700000
 fiber optic cabling.

0:02:22.700000 --> 0:02:26.540000
 So just by looking at the interface you
 can tell which type of cable you're

0:02:26.540000 --> 0:02:28.080000
 going to have to procure.

0:02:28.080000 --> 0:02:30.840000
 Now let's spend a little bit of time
 first of all talking about copper

0:02:30.840000 --> 0:02:34.100000
 cabling and the various differences
 you'll see there.

0:02:34.100000 --> 0:02:38.160000
 So with copper cabling there's a lot
 of distinctive characteristics of

0:02:38.160000 --> 0:02:42.320000
 copper cable. For one thing they're a
 lot thicker than fiber optic cable.

0:02:42.320000 --> 0:02:44.380000
 That's one way you
 can identify them.

0:02:44.380000 --> 0:02:47.220000
 Also there's clearly copper
 inside the cable.

0:02:47.220000 --> 0:02:50.280000
 If you were to snip it with a wire cutter
 or something like that inside

0:02:50.280000 --> 0:02:54.100000
 you would see one or more
 strands of copper.

0:02:54.100000 --> 0:02:57.260000
 And that's being used to carry your
 electrical signaling back and forth

0:02:57.260000 --> 0:03:02.680000
 on that cable. And there's three primary
 uses of copper cabling when it

0:03:02.680000 --> 0:03:05.480000
 comes to carrying data,
 voice or video signals.

0:03:05.480000 --> 0:03:10.320000
 You're looking at Ethernet cables,
 coaxial cables and serial cables.

0:03:10.320000 --> 0:03:13.360000
 We're going to talk about all three
 of those in pretty good detail here

0:03:13.360000 --> 0:03:14.960000
 in this section.

0:03:14.960000 --> 0:03:17.160000
 So let's start by talking
 about Ethernet.

0:03:17.160000 --> 0:03:21.040000
 Maybe somebody says to you, hey I want
 you to go and find a replacement

0:03:21.040000 --> 0:03:23.000000
 Ethernet cable for me.

0:03:23.000000 --> 0:03:25.880000
 Well they're actually going to have
 to give you a little bit more detail

0:03:25.880000 --> 0:03:29.120000
 than that for you to satisfy
 that objective.

0:03:29.120000 --> 0:03:33.840000
 When Ethernet very first came out
 it came out using copper cabling.

0:03:33.840000 --> 0:03:37.800000
 So the original Ethernet was something
 on what's called thick net which

0:03:37.800000 --> 0:03:40.960000
 looked very similar
 to coaxial cabling.

0:03:40.960000 --> 0:03:44.740000
 The connector was a little bit different
 but it looked like coaxial cabling.

0:03:44.740000 --> 0:03:49.460000
 Then not too many years later Ethernet
 evolved over time to support copper

0:03:49.460000 --> 0:03:52.880000
 as well as fiber optic connectors.


0:03:52.880000 --> 0:03:55.840000
 So the main point I want to come across
 to you here is if somebody just

0:03:55.840000 --> 0:03:58.980000
 simply says to you, hey I need
 a replacement Ethernet cable.

0:03:58.980000 --> 0:04:02.980000
 Question number one you need to get
 answered is do they need a copper

0:04:02.980000 --> 0:04:06.500000
 or a fiber optic Ethernet cable.

0:04:06.500000 --> 0:04:09.000000
 Now let's say they want
 a copper Ethernet cable.

0:04:09.000000 --> 0:04:14.440000
 Okay next question you have to answer
 is do you want a coaxial cable?

0:04:14.440000 --> 0:04:18.800000
 Probably not. They'll probably tell you
 they want a twisted pair Ethernet

0:04:18.800000 --> 0:04:22.260000
 cable. What exactly
 is twisted pair?

0:04:22.260000 --> 0:04:23.720000
 Let's go into the details of that.


0:04:23.720000 --> 0:04:26.300000
 So twisted pair is just
 like it sounds.

0:04:26.300000 --> 0:04:29.560000
 If you break open or cut through a twisted
 pair Ethernet cable you will

0:04:29.560000 --> 0:04:34.760000
 see multiple pairs of wires are
 twisted around each other.

0:04:34.760000 --> 0:04:39.600000
 So the wires come in pairs with each
 every two wires in a single pair

0:04:39.600000 --> 0:04:43.860000
 forming an electrical current
 like you see here.

0:04:43.860000 --> 0:04:48.040000
 So it's a pair of copper cables that
 forms a complete electrical loop.

0:04:48.040000 --> 0:04:52.120000
 Now the pairs are twisted around themselves
 to prevent electromagnetic

0:04:52.120000 --> 0:04:57.780000
 interference. If we're talking about
 a 10 megabit or 100 megabit Ethernet

0:04:57.780000 --> 0:05:03.220000
 well you technically only need two pairs
 of wires or four wires in total.

0:05:03.220000 --> 0:05:06.640000
 Other flavors of Ethernet for example
 gigabit Ethernet can use either

0:05:06.640000 --> 0:05:09.880000
 four or even eight pairs of wires.


0:05:09.880000 --> 0:05:13.500000
 But the main point is in twisted pair
 those pairs of wires are actually

0:05:13.500000 --> 0:05:16.020000
 physically twisted
 around each other.

0:05:16.020000 --> 0:05:18.420000
 And you can see that right
 here in this picture.

0:05:18.420000 --> 0:05:22.700000
 As we cut open the outside of an Ethernet
 cable you can clearly see that

0:05:22.700000 --> 0:05:27.320000
 each pair of wires here is
 twisted around each other.

0:05:27.320000 --> 0:05:32.540000
 So that is right now four pairs
 of wires each having twists.

0:05:32.540000 --> 0:05:37.320000
 And twisted pair cabling typically is
 terminated with an RJ45 jack which

0:05:37.320000 --> 0:05:39.120000
 we saw in the previous slide.

0:05:39.120000 --> 0:05:42.960000
 So let's say somebody says okay yes I
 want you to get me an Ethernet cable.

0:05:42.960000 --> 0:05:47.800000
 I need to be copper and I
 need to be twisted pair.

0:05:47.800000 --> 0:05:51.080000
 Well at that point you're going to sound
 like you're an irritant but you

0:05:51.080000 --> 0:05:54.180000
 need even a little more information
 to be able to identify the specific

0:05:54.180000 --> 0:05:57.060000
 cable that person's looking for.

0:05:57.060000 --> 0:06:02.100000
 Because twisted pair Ethernet cabling
 comes in two general categories

0:06:02.100000 --> 0:06:04.400000
 or two different variants.

0:06:04.400000 --> 0:06:07.680000
 The first is what's called
 straight through cable.

0:06:07.680000 --> 0:06:10.400000
 So straight through cable we
 can see it here on the left.

0:06:10.400000 --> 0:06:15.940000
 It's identified where if you hold up
 your RJ45 ends together each pin

0:06:15.940000 --> 0:06:21.580000
 corresponds to the same color as that
 same corresponding pin on the other

0:06:21.580000 --> 0:06:22.880000
 end of the cable.

0:06:22.880000 --> 0:06:26.600000
 So for example pin one if it's brown
 and white it'll be brown and white

0:06:26.600000 --> 0:06:28.460000
 pin one on the other side.

0:06:28.460000 --> 0:06:33.680000
 Pin four if it's blue well pin four
 on the other side will also be blue.

0:06:33.680000 --> 0:06:37.040000
 That is considered a straight through
 cable if it looks like that.

0:06:37.040000 --> 0:06:40.060000
 Straight through cables are used to
 connect devices together that reside

0:06:40.060000 --> 0:06:43.600000
 at different layers
 of the OSI model.

0:06:43.600000 --> 0:06:48.220000
 For example a PC or laptop is considered
 a layer three device just like

0:06:48.220000 --> 0:06:52.340000
 a router whereas a switch is considered
 a layer two device.

0:06:52.340000 --> 0:06:57.880000
 So if I was to connect a PC or
 laptop directly to a router.

0:06:57.880000 --> 0:07:03.600000
 So if I was to connect that I'm sorry
 a PC or laptop to a switch will

0:07:03.600000 --> 0:07:08.100000
 switch and a PCR devices are at different
 layers of the OSI model.

0:07:08.100000 --> 0:07:11.820000
 We've got a layer two device connecting
 to a layer three device.

0:07:11.820000 --> 0:07:15.140000
 In that particular case I'd be using
 a straight through cable to connect

0:07:15.140000 --> 0:07:19.760000
 them. The other variety of twisted pair
 cable for Ethernet is what's called

0:07:19.760000 --> 0:07:23.040000
 a crossover cable and you can clearly
 see that here that when you hold

0:07:23.040000 --> 0:07:27.000000
 those ends up next to each
 other pin one on one side.

0:07:27.000000 --> 0:07:36.100000
 One side goes to pin three on the other
 side and pin two on one side goes

0:07:36.100000 --> 0:07:38.820000
 to pin six on the other side.

0:07:38.820000 --> 0:07:44.200000
 So one to three two to six that is how
 a crossover cable is identified.

0:07:44.200000 --> 0:07:47.960000
 And when you want to connect devices
 together they're at the same layer

0:07:47.960000 --> 0:07:49.340000
 of the OSI model.

0:07:49.340000 --> 0:07:53.180000
 For example if I'm connecting two laptops
 directly back to back with an

0:07:53.180000 --> 0:07:57.880000
 Ethernet cable or two switches back to
 back with an Ethernet cable I would

0:07:57.880000 --> 0:08:00.700000
 use a crossover cable to do that.

0:08:00.700000 --> 0:08:04.080000
 Now a lot of devices these days have
 interfaces which are labeled auto

0:08:04.080000 --> 0:08:09.640000
 dash MDIX. That's a special type of interface
 that can automatically detect

0:08:09.640000 --> 0:08:12.540000
 the cable type and account for it.


0:08:12.540000 --> 0:08:15.120000
 So you don't really have to be that
 concerned if you're using straight

0:08:15.120000 --> 0:08:16.060000
 through or crossover.

0:08:16.060000 --> 0:08:19.340000
 But you should be aware that when it comes
 to twisted pair Ethernet cabling

0:08:19.340000 --> 0:08:24.660000
 it does come in two different flavors
 straight through and crossover.

0:08:24.660000 --> 0:08:29.760000
 Now even that might not be enough information
 because in addition to Ethernet

0:08:29.760000 --> 0:08:33.740000
 being straight through or crossover
 twisted pair also comes in different

0:08:33.740000 --> 0:08:38.580000
 categories. For example you may have
 heard of category five Ethernet or

0:08:38.580000 --> 0:08:40.140000
 category six Ethernet.

0:08:40.140000 --> 0:08:46.160000
 And what this means is that the higher
 the category the more twists per

0:08:46.160000 --> 0:08:51.000000
 centimeter you're going to have and the
 thicker the sheath thickness will

0:08:51.000000 --> 0:08:54.800000
 be this preventing electromagnetic
 interference.

0:08:54.800000 --> 0:08:59.220000
 So as the category gets higher those
 things change which means you can

0:08:59.220000 --> 0:09:02.520000
 have a higher speed on that cable.


0:09:02.520000 --> 0:09:05.080000
 For example take a
 look right here.

0:09:05.080000 --> 0:09:12.340000
 We've got category five compare the
 twists we have in that area with the

0:09:12.340000 --> 0:09:17.060000
 twists we would have in the same area
 in a category six clearly there

0:09:17.060000 --> 0:09:21.960000
 are more twists per inch or twists per
 centimeter in a category six than

0:09:21.960000 --> 0:09:22.920000
 a category five.

0:09:22.920000 --> 0:09:28.760000
 And the more twists you have the better that
 cable is at preventing electromagnetic

0:09:28.760000 --> 0:09:34.260000
 interference from one wire pair interfering
 with another wire pair.

0:09:34.260000 --> 0:09:37.320000
 Of course you're going to pay for that
 the higher the category of cable

0:09:37.320000 --> 0:09:41.280000
 the more expensive the
 category of cable.

0:09:41.280000 --> 0:09:44.800000
 And we also talked about the sheath
 thickness take a look at this here

0:09:44.800000 --> 0:09:49.020000
 we can see compare the category six
 with the category five you don't see

0:09:49.020000 --> 0:09:49.920000
 a lot of difference.

0:09:49.920000 --> 0:09:53.720000
 But the outside sheath is actually a
 little bit thicker on the category

0:09:53.720000 --> 0:09:59.540000
 six than the category five once again designed
 to help minimize electromagnetic

0:09:59.540000 --> 0:10:04.380000
 interference in this case from the outside
 world from penetrating those

0:10:04.380000 --> 0:10:06.580000
 wires within the cable.

0:10:06.580000 --> 0:10:11.320000
 And we're not done yet so even if you
 know that you need twisted pair

0:10:11.320000 --> 0:10:16.540000
 even if you know that you need category
 five or category six even if you're

0:10:16.540000 --> 0:10:18.680000
 told you need a straight
 through or a crossover.

0:10:18.680000 --> 0:10:22.300000
 Well if you're going to get really nitty
 gritty there's another variant

0:10:22.300000 --> 0:10:25.920000
 we have to consider with all of those
 things which is is the cable I'm

0:10:25.920000 --> 0:10:30.760000
 looking for shielded or unshielded
 and we can see those examples right

0:10:30.760000 --> 0:10:35.460000
 here. So most ethernet cables that you'll
 see that are like running along

0:10:35.460000 --> 0:10:40.360000
 the floor or running you know along the
 ceiling are what's called unshielded

0:10:40.360000 --> 0:10:46.540000
 twisted pair. The best way to describe
 unshielded twisted pair is actually

0:10:46.540000 --> 0:10:51.300000
 to contrast that against shielded twisted
 pair here in shielded twisted

0:10:51.300000 --> 0:10:55.780000
 pair every pair of wires is actually
 covered as you can see here with

0:10:55.780000 --> 0:11:00.460000
 sort of like an aluminum shielding
 which once again is even better at

0:11:00.460000 --> 0:11:04.500000
 preventing electromagnetic interference
 from both the outside world as

0:11:04.500000 --> 0:11:08.400000
 well as between the pairs
 of wires themselves.

0:11:08.400000 --> 0:11:11.720000
 Now this is going to cost you even
 more money to have shielded twisted

0:11:11.720000 --> 0:11:16.760000
 pair. Typically people would recommend
 putting shielded twisted pair when

0:11:16.760000 --> 0:11:21.540000
 you have cables running across areas that
 have high electromagnetic interference

0:11:21.540000 --> 0:11:26.300000
 such as running cables outdoors or
 maybe inside walls are going to be

0:11:26.300000 --> 0:11:29.720000
 right next to like high powered
 electrical lines.

0:11:29.720000 --> 0:11:33.860000
 And so if we bring it all together here
 you can see the different categories

0:11:33.860000 --> 0:11:38.860000
 the maximum lengths you can run you
 can see the higher the category the

0:11:38.860000 --> 0:11:42.380000
 higher the speed that you
 can run across that cable.

0:11:42.380000 --> 0:11:47.660000
 Now that's all talking about
 twisted pair cabling.

0:11:47.660000 --> 0:11:51.200000
 So what if I need a copper cabling
 that's not twisted pair what if the

0:11:51.200000 --> 0:11:55.440000
 particular port adapter or module I'm
 looking at actually uses coaxial

0:11:55.440000 --> 0:11:59.540000
 cabling. Well how would I identify coaxial
 cabling if you've never heard

0:11:59.540000 --> 0:12:00.840000
 that term before.

0:12:00.840000 --> 0:12:03.980000
 Well coaxial cabling looks like the typical
 cable that goes to your cable

0:12:03.980000 --> 0:12:10.020000
 TV. As you can see here it's basically
 got just a single wire it actually

0:12:10.020000 --> 0:12:13.900000
 it's a little misleading here it's not
 even though it looks like a single

0:12:13.900000 --> 0:12:15.580000
 wire right here just popping out.

0:12:15.580000 --> 0:12:20.160000
 That single wire which is the copper
 wire is actually surrounded by a

0:12:20.160000 --> 0:12:24.280000
 copper mesh. And this copper mesh is not
 only helping to prevent electromagnetic

0:12:24.280000 --> 0:12:29.380000
 interference that copper mesh is actually
 also transmitting electrical

0:12:29.380000 --> 0:12:34.100000
 signal just like this
 inner wire is doing.

0:12:34.100000 --> 0:12:38.000000
 Now coaxial cable is better at preventing
 electromagnetic interference

0:12:38.000000 --> 0:12:42.980000
 than twisted pair because it has this
 very thick insulation separating

0:12:42.980000 --> 0:12:47.200000
 the inner copper wire
 from the copper mesh.

0:12:47.200000 --> 0:12:49.200000
 So in that way it's better
 at preventing EMI.

0:12:49.200000 --> 0:12:51.880000
 Now it's more difficult to install
 than twisted pair because it's not

0:12:51.880000 --> 0:12:57.300000
 as bendable it's thicker less bendable
 than twisted pair cabling is.

0:12:57.300000 --> 0:13:02.780000
 Now the upside of this is in addition
 to being really good at preventing

0:13:02.780000 --> 0:13:08.800000
 EMI it can carry signals further a
 further distance than twisted pair

0:13:08.800000 --> 0:13:13.820000
 cabling. And you can see it uses a BNC
 connector so the connector is very

0:13:13.820000 --> 0:13:18.500000
 different. And usually when you're going
 to find coaxial cable and networking

0:13:18.500000 --> 0:13:21.960000
 is for cable modem connections that's
 where you're most likely going to

0:13:21.960000 --> 0:13:27.040000
 find it. Now what other types of cables
 might you be asked to identify?

0:13:27.040000 --> 0:13:30.560000
 Well you also need to know what console
 and auxiliary port cables look

0:13:30.560000 --> 0:13:37.400000
 like. Now console and aux ports typically
 have RJ45 connectors like we

0:13:37.400000 --> 0:13:42.300000
 see right here. But this RJ45 connector
 is not being used to carry Ethernet

0:13:42.300000 --> 0:13:46.680000
 signals. This is just being used
 strictly to carry ASCII data.

0:13:46.680000 --> 0:13:50.280000
 So the cable that connects to this is
 not going to be your typical Ethernet

0:13:50.280000 --> 0:13:54.040000
 cable. You're going to have what's
 called a rolled cable.

0:13:54.040000 --> 0:13:58.400000
 So the pin out in a rolled cable is
 actually like it says it's exactly

0:13:58.400000 --> 0:14:02.140000
 from one side it's opposite
 of the other side.

0:14:02.140000 --> 0:14:07.860000
 So for example if I have here light
 tan and white on pin number one that

0:14:07.860000 --> 0:14:12.160000
 will go over to the exact opposite pin
 or pin number eight on the other

0:14:12.160000 --> 0:14:16.360000
 side. Now let's hear pin number two
 will go all the way to the opposite

0:14:16.360000 --> 0:14:19.580000
 which is pin number seven
 on the opposite side.

0:14:19.580000 --> 0:14:24.180000
 So this is not for Ethernet signaling
 this is for console or aux ports.

0:14:24.180000 --> 0:14:30.240000
 And usually that will come the form
 factor of a flat blue cable.

0:14:30.240000 --> 0:14:35.480000
 And these will be using and in case
 you're wondering so on one end of

0:14:35.480000 --> 0:14:38.820000
 this console port cable you've
 got the RJ45 connector.

0:14:38.820000 --> 0:14:42.180000
 So that's connecting right
 here to the console port.

0:14:42.180000 --> 0:14:44.860000
 This right here is
 a DB9 connector.

0:14:44.860000 --> 0:14:50.880000
 Now maybe you're lucky enough to have a
 laptop that has a native DB9 interface

0:14:50.880000 --> 0:14:55.260000
 on it. If not which you probably don't
 have you'll probably need to get

0:14:55.260000 --> 0:15:01.640000
 a DB9 to USB converter or what's
 called a USB to serial converter.

0:15:01.640000 --> 0:15:06.700000
 So you can plug it into the
 USB port on your laptop.

0:15:06.700000 --> 0:15:10.580000
 So now let's go into the world of serial
 cables lots of different form

0:15:10.580000 --> 0:15:13.280000
 factors of serial cables.

0:15:13.280000 --> 0:15:19.220000
 Serial cables are another variant of
 a copper cable and many types exist.

0:15:19.220000 --> 0:15:22.360000
 You can see here lots of
 different form factors.

0:15:22.360000 --> 0:15:25.660000
 So if someone asks you hey I want you
 to get a replacement serial cable

0:15:25.660000 --> 0:15:30.540000
 from my router. Well there's three main
 questions you need to ask to make

0:15:30.540000 --> 0:15:32.260000
 sure you select the right one.

0:15:32.260000 --> 0:15:39.440000
 Number one is the router being connected
 to a DTE or a DCE device.

0:15:39.440000 --> 0:15:41.420000
 And here you can see what
 those acronyms stand for.

0:15:41.420000 --> 0:15:42.920000
 You need to know that.

0:15:42.920000 --> 0:15:47.980000
 Do you need a male or a female
 connector on the cable itself?

0:15:47.980000 --> 0:15:52.380000
 And what signaling standard
 does the device require?

0:15:52.380000 --> 0:15:55.240000
 Answers to these three questions will
 help you narrow down what specific

0:15:55.240000 --> 0:16:00.200000
 cable you need. Let's start
 talking about DTE or DCE.

0:16:00.200000 --> 0:16:04.260000
 So DTE you can see it's
 data terminal equipment.

0:16:04.260000 --> 0:16:09.320000
 Here's a little definition
 of what DTE is.

0:16:09.320000 --> 0:16:16.360000
 In case you've never seen a DSU CSU
 that is a box that looks like this.

0:16:16.360000 --> 0:16:22.000000
 And so the cable, so the DTE side of
 the cable will actually connect to

0:16:22.000000 --> 0:16:22.960000
 something like this.

0:16:22.960000 --> 0:16:26.480000
 Right? The DTE side of the cable will
 connect into your router or into

0:16:26.480000 --> 0:16:32.440000
 the CSU, DSU. Now some routers actually
 have a DSU CSU built right into

0:16:32.440000 --> 0:16:37.260000
 it directly. So clearly as we can see
 here on this side, this is not going

0:16:37.260000 --> 0:16:38.760000
 to accept a serial cable.

0:16:38.760000 --> 0:16:44.880000
 This is going to accept a twisted pair
 cable because using an RJ45 jack.

0:16:44.880000 --> 0:16:53.120000
 DCE data circuit terminating equipment
 is basically a device like a modem

0:16:53.120000 --> 0:16:57.260000
 that provides clocking to a DTE.

0:16:57.260000 --> 0:17:00.960000
 Most serial cables, if you hold them
 very closely to your eyeballs, one

0:17:00.960000 --> 0:17:04.200000
 side will actually
 be labeled as DTE.

0:17:04.200000 --> 0:17:07.040000
 One side will be labeled as DCE.

0:17:07.040000 --> 0:17:09.960000
 So you need to know which side of
 the cable are you plugging into?

0:17:09.960000 --> 0:17:12.260000
 Which device is the DCE?

0:17:12.260000 --> 0:17:18.180000
 Which device is the DTE so you can
 plug your cable in correctly?

0:17:18.180000 --> 0:17:21.220000
 And of course you need to know, do
 I need a male or a female connector

0:17:21.220000 --> 0:17:24.020000
 or male or female cable?

0:17:24.020000 --> 0:17:28.020000
 Here we have an example of a cable that
 has a male end on one and a female

0:17:28.020000 --> 0:17:29.400000
 end on the other.

0:17:29.400000 --> 0:17:34.540000
 Here's a cable where both ends are
 male and here's another cable where

0:17:34.540000 --> 0:17:36.680000
 both ends are female.

0:17:36.680000 --> 0:17:37.780000
 So you need to know that.

0:17:37.780000 --> 0:17:43.100000
 What kind of connectors do I
 need to plug my cable into?

0:17:43.100000 --> 0:17:45.440000
 And then lastly, what
 signaling standards?

0:17:45.440000 --> 0:17:49.120000
 So the signaling standards define things
 like what signals are going to

0:17:49.120000 --> 0:17:50.300000
 be used on that cable.

0:17:50.300000 --> 0:17:53.800000
 What are the pin outs that will
 be carrying those signals?

0:17:53.800000 --> 0:17:55.500000
 And what does the connector
 look like?

0:17:55.500000 --> 0:17:59.680000
 For example, here we see three examples
 of different signaling styles

0:17:59.680000 --> 0:18:02.560000
 or signaling protocols
 or signaling standards.

0:18:02.560000 --> 0:18:06.060000
 These are all three different
 serial cables.

0:18:06.060000 --> 0:18:09.180000
 And if you go to that URL there, you'll
 see there are lots and lots of

0:18:09.180000 --> 0:18:12.580000
 different serial cables
 that are supported.

0:18:12.580000 --> 0:18:16.600000
 So not only do you need to know, do
 I need a male or female cable, you

0:18:16.600000 --> 0:18:21.720000
 need to know what signaling standard the
 device supports so you can connect

0:18:21.720000 --> 0:18:24.480000
 the correct cable to it.

0:18:24.480000 --> 0:18:26.260000
 So enough of copper cable.

0:18:26.260000 --> 0:18:27.920000
 So that covers our copper cabling.


0:18:27.920000 --> 0:18:31.880000
 Let's move into the world of fiber
 optic cabling and talk a little bit

0:18:31.880000 --> 0:18:36.040000
 about that. So here we see
 fiber optic cabling.

0:18:36.040000 --> 0:18:39.380000
 And there's some distinctive characteristics
 of fiber optic.

0:18:39.380000 --> 0:18:43.980000
 Number one, fiber optic cables use
 very, very thin glass filaments or

0:18:43.980000 --> 0:18:46.220000
 fibers to carry light.

0:18:46.220000 --> 0:18:51.540000
 So light is being used to carry your
 data, not electrical energy, light

0:18:51.540000 --> 0:18:55.780000
 energy. It's much thinner than ethernet
 cable and it's much more flexible

0:18:55.780000 --> 0:19:00.620000
 than ethernet cable and it's typically
 more costly than ethernet cable.

0:19:00.620000 --> 0:19:05.620000
 So there's two general classifications
 of fiber optic cable, multi mode

0:19:05.620000 --> 0:19:09.260000
 fiber and single mode fiber.

0:19:09.260000 --> 0:19:12.120000
 So let's talk a little
 bit about that.

0:19:12.120000 --> 0:19:14.020000
 So that's one thing you'll
 need to understand.

0:19:14.020000 --> 0:19:16.860000
 If somebody says, hey, I need you to
 get me a fiber cable from my ethernet

0:19:16.860000 --> 0:19:21.980000
 port, you'll need to ask them, do I need
 a multi mode or single mode cable?

0:19:21.980000 --> 0:19:25.920000
 So the main differentiator
 is the size of the core.

0:19:25.920000 --> 0:19:26.820000
 What do I mean by the core?

0:19:26.820000 --> 0:19:29.880000
 Let me go back one slide here for just
 a second and point out that in

0:19:29.880000 --> 0:19:34.480000
 a fiber optic cable, this little tiny
 piece of fiber right here is what

0:19:34.480000 --> 0:19:38.440000
 we call the core and that's the strand
 of glass used to actually carry

0:19:38.440000 --> 0:19:44.480000
 the light. And then this here, the cladding
 is also composed of another

0:19:44.480000 --> 0:19:48.860000
 layer of glass that's
 surrounding the core.

0:19:48.860000 --> 0:19:52.140000
 Now the cladding, however, has a different
 refractive index, which basically

0:19:52.140000 --> 0:19:56.920000
 ensures that the light that bounces
 around remains totally within the

0:19:56.920000 --> 0:19:59.660000
 core. We don't want the
 light leaving the core.

0:19:59.660000 --> 0:20:04.020000
 That core might be miles and miles long
 and it has to contain the light

0:20:04.020000 --> 0:20:07.700000
 that enters in it so it pops
 out on the other side.

0:20:07.700000 --> 0:20:10.180000
 So now we know what the core
 and the cladding is.

0:20:10.180000 --> 0:20:13.340000
 What does this have to do with multi
 mode fiber versus single mode fiber?

0:20:13.340000 --> 0:20:17.480000
 Well, if we're looking at the core,
 as we can see here in this slide,

0:20:17.480000 --> 0:20:21.320000
 multi mode fiber has a
 larger diameter core.

0:20:21.320000 --> 0:20:26.220000
 It's thicker. So it allows multiple
 modes or rays of light to propagate.

0:20:26.220000 --> 0:20:30.860000
 Where a single mode fiber has a very
 narrow core, only allowing a single

0:20:30.860000 --> 0:20:34.320000
 mode of light. Was
 this translate to?

0:20:34.320000 --> 0:20:36.700000
 Well, multi mode fiber is cheaper.


0:20:36.700000 --> 0:20:39.980000
 It's less expensive because the type
 of light is going to be generated

0:20:39.980000 --> 0:20:47.060000
 by a less expensive light source, typically
 an LED or an inexpensive laser.

0:20:47.060000 --> 0:20:51.060000
 Whereas single mode fiber is more expensive
 cable because it requires

0:20:51.060000 --> 0:20:56.020000
 a more expensive high powered
 laser to generate that light.

0:20:56.020000 --> 0:20:59.120000
 Another distinctive difference between
 multi mode and single mode fiber

0:20:59.120000 --> 0:21:01.580000
 is how long they can be.

0:21:01.580000 --> 0:21:03.840000
 Multi mode fiber is
 limited on distance.

0:21:03.840000 --> 0:21:06.700000
 You're typically going to be using
 it for connections between devices

0:21:06.700000 --> 0:21:10.460000
 that are anywhere from 20 to 50
 meters apart from each other.

0:21:10.460000 --> 0:21:15.060000
 But if I need to run a fiber optic cable
 across a long distance, that's

0:21:15.060000 --> 0:21:17.160000
 where I'm going to be using
 a single mode fiber.

0:21:17.160000 --> 0:21:22.620000
 Single mode fiber can support distances
 up to several thousands of kilometers.

0:21:22.620000 --> 0:21:27.220000
 Now, if I was actually holding up some
 fiber optic cables in my hands,

0:21:27.220000 --> 0:21:31.800000
 how would I be able to tell which one
 is single mode fiber and which one

0:21:31.800000 --> 0:21:33.740000
 is multi mode fiber?

0:21:33.740000 --> 0:21:36.420000
 Well, hopefully there's going to be
 some printing on the outer jacket

0:21:36.420000 --> 0:21:38.520000
 of the cable that actually
 tells you that.

0:21:38.520000 --> 0:21:39.940000
 That is your best bet.

0:21:39.940000 --> 0:21:43.260000
 Take out your magnifying glass
 and look for that printing.

0:21:43.260000 --> 0:21:46.980000
 Another way that you can tell, now
 this isn't always standardized, is

0:21:46.980000 --> 0:21:49.100000
 the color on the outside
 of the cable.

0:21:49.100000 --> 0:21:53.860000
 You can see here that generally speaking,
 your various flavors of multi

0:21:53.860000 --> 0:21:58.180000
 mode cable will usually
 be orange in color.

0:21:58.180000 --> 0:22:02.700000
 Orange is the most common color
 here of multi mode cables.

0:22:02.700000 --> 0:22:06.200000
 Where as single mode cable
 is usually yellow.

0:22:06.200000 --> 0:22:11.720000
 So single mode fiber is typically
 yellow in color.

0:22:11.720000 --> 0:22:16.620000
 And lastly, fiber cables are terming with
 a variety of different connectors

0:22:16.620000 --> 0:22:18.200000
 as you can see here.

0:22:18.200000 --> 0:22:21.840000
 So if you ever see these types of connectors
 on the end of a cable, you're

0:22:21.840000 --> 0:22:25.300000
 looking at a fiber optic cable.

0:22:25.300000 --> 0:22:27.200000
 So that concludes this
 particular video.

