WEBVTT

0:00:05.680000 --> 0:00:09.260000
 So far in this video series, I've referenced
 this term, Ethernet frame

0:00:09.260000 --> 0:00:12.440000
 quite a bit, but we haven't really
 looked at what is that.

0:00:12.440000 --> 0:00:16.460000
 In other words, I've said that when
 your NIC card sends out its bits,

0:00:16.460000 --> 0:00:20.520000
 it gathers them and formats them into
 this thing, the structure, this

0:00:20.520000 --> 0:00:23.980000
 protocol data unit called
 an Ethernet frame.

0:00:23.980000 --> 0:00:27.860000
 Then it uses carrier sense, multiple
 access to know when it can send the

0:00:27.860000 --> 0:00:31.300000
 frame, and if the frame has
 collided with anything else.

0:00:31.300000 --> 0:00:32.860000
 But was the frame actually
 look like?

0:00:32.860000 --> 0:00:35.960000
 Well, let's take a look at them.

0:00:35.960000 --> 0:00:40.800000
 So in the original Ethernet implementation
 and then an Ethernet version

0:00:40.800000 --> 0:00:47.020000
 2, which is called Ethernet Dix here
 for digital Intel and Xerox, we can

0:00:47.020000 --> 0:00:50.240000
 see the original Ethernet
 frame structure up top.

0:00:50.240000 --> 0:00:51.940000
 And then when Dr.

0:00:51.940000 --> 0:00:56.900000
 Robert Metcalf and some of his engineering
 friends formed the 802.comity,

0:00:56.900000 --> 0:01:00.540000
 the 802. And then they formed
 the 802.3 working group.

0:01:00.540000 --> 0:01:07.220000
 They modified a little bit and 802.3
 looks almost the same as Ethernet,

0:01:07.220000 --> 0:01:10.260000
 but you can see here the main change
 is that while Ethernet had a type

0:01:10.260000 --> 0:01:13.300000
 code, 802.3 has a length field.

0:01:13.300000 --> 0:01:16.540000
 So let's dig into each one of these
 fields here and see what do these

0:01:16.540000 --> 0:01:17.580000
 fields represent?

0:01:17.580000 --> 0:01:18.920000
 What are they used for?

0:01:18.920000 --> 0:01:24.720000
 So let's start with the
 first field, the pre-ed.

0:01:24.720000 --> 0:01:30.940000
 So the preamble is 7 bytes of this
 recurring pattern called 10101010.

0:01:30.940000 --> 0:01:32.040000
 So that's the preamble.

0:01:32.040000 --> 0:01:35.620000
 And the purpose of the preamble is
 simply so that the receiving device

0:01:35.620000 --> 0:01:37.920000
 can synchronize its clocking.

0:01:37.920000 --> 0:01:42.820000
 In other words, the receiving device
 will know exactly when to scan the

0:01:42.820000 --> 0:01:47.940000
 wire, probe the wire to make sure
 it picks up a 1, picks up a 0.

0:01:47.940000 --> 0:01:53.080000
 Because remember the way Ethernet works
 is that I'm going to hold my voltage

0:01:53.080000 --> 0:01:58.300000
 up to a certain level for a certain
 amount of time to represent a 1.

0:01:58.300000 --> 0:01:59.900000
 Then I'm going to let it go.

0:01:59.900000 --> 0:02:03.240000
 I'm going to wait a few nanoseconds
 and then hold it up to a different

0:02:03.240000 --> 0:02:06.900000
 level for a amount
 of time for a 0.

0:02:06.900000 --> 0:02:13.360000
 So if I'm sending this to you, your receiving
 circuitry has to be monitoring

0:02:13.360000 --> 0:02:19.260000
 that wire at the precise time to look
 when to get that voltage level,

0:02:19.260000 --> 0:02:21.020000
 to know when to see the 1s and 0s.


0:02:21.020000 --> 0:02:22.600000
 So the clocking has
 to be the same.

0:02:22.600000 --> 0:02:26.080000
 If I'm putting the bits on the wire at
 this rate, you have to be sampling

0:02:26.080000 --> 0:02:28.920000
 the bits off the wire
 at the same rate.

0:02:28.920000 --> 0:02:34.080000
 So in order to ensure that, we have
 the 7 bytes here of the preamble.

0:02:34.080000 --> 0:02:38.560000
 And after that, we have one more byte
 called the start of frame delimiter,

0:02:38.560000 --> 0:02:40.740000
 the start of frame delimiter.

0:02:40.740000 --> 0:02:45.120000
 Now what does 543 rule have to do?


0:02:45.120000 --> 0:02:48.940000
 This is just some sort of like historic
 artifact, but I thought you might

0:02:48.940000 --> 0:02:51.620000
 find an interesting case
 you ever ran across it.

0:02:51.620000 --> 0:02:57.840000
 So in the old days of Ethernet,
 the 543 rule simply said this.

0:02:57.840000 --> 0:03:02.280000
 That, you know, Ethernet when it was
 developed, one of the things they

0:03:02.280000 --> 0:03:11.800000
 had to determine was, when I put a bit
 on the wire, a 1 or a 0, how far

0:03:11.800000 --> 0:03:13.200000
 do I want it to go?

0:03:13.200000 --> 0:03:16.680000
 Because think about how this is actually
 happening at the physical layer.

0:03:16.680000 --> 0:03:20.240000
 It's like I'm putting some electrical
 energy on the wire, and my rule

0:03:20.240000 --> 0:03:24.760000
 state has to be a certain level held
 at a certain amount of time, so that

0:03:24.760000 --> 0:03:28.740000
 you can recognize
 it as a 1 or a 0.

0:03:28.740000 --> 0:03:31.320000
 Here's the thing with electrical
 energy though.

0:03:31.320000 --> 0:03:35.640000
 If you put electrical energy on the wire,
 the farther and farther it gets

0:03:35.640000 --> 0:03:40.100000
 away from the source, it becomes
 what's called attenuated.

0:03:40.100000 --> 0:03:43.500000
 Attenuated means that electrical energy
 gets more and more dissipated

0:03:43.500000 --> 0:03:46.540000
 less and less what it looked
 like at the beginning.

0:03:46.540000 --> 0:03:50.460000
 So if I put a nice, nice solid wave
 on the wire, you know, I'm holding

0:03:50.460000 --> 0:03:54.460000
 it a nice solid consistency for a certain
 amount of time, then I let it

0:03:54.460000 --> 0:04:01.660000
 go, that wave gets sort of distorted
 the further and further you go away

0:04:01.660000 --> 0:04:02.840000
 from the source.

0:04:02.840000 --> 0:04:05.660000
 That's called attenuation.

0:04:05.660000 --> 0:04:10.200000
 So if I have two things that are really
 close to each other, there's not

0:04:10.200000 --> 0:04:11.620000
 much attenuation there.

0:04:11.620000 --> 0:04:14.040000
 So I don't have to use a whole
 lot of electrical energy.

0:04:14.040000 --> 0:04:18.280000
 I don't have to use a big massive battery
 or a big electrical source to

0:04:18.280000 --> 0:04:21.980000
 put energy on that wire because the
 receiving device is so close to me

0:04:21.980000 --> 0:04:25.820000
 that the electrical energy won't change
 much between point A and point

0:04:25.820000 --> 0:04:31.720000
 B. But if point A and point B are really
 far apart, and I know that that

0:04:31.720000 --> 0:04:35.080000
 electrical energy is going
 to dissipate by a 3.

0:04:35.080000 --> 0:04:37.900000
 So if I have to think to myself, okay,
 well if they're going to be really

0:04:37.900000 --> 0:04:40.780000
 far apart, that means the electrical
 energy at the beginning has to be

0:04:40.780000 --> 0:04:44.780000
 really strong. So that by the time it
 gets here, even though it's gotten

0:04:44.780000 --> 0:04:49.380000
 weaker, it's still strong enough for
 point B to be able to receive it

0:04:49.380000 --> 0:04:52.580000
 and to be able to tell
 that it's a 1 or a 0.

0:04:52.580000 --> 0:04:54.360000
 So it's a trade-off,
 it's a balance.

0:04:54.360000 --> 0:04:59.280000
 So the desires of ethernet said, well,
 we could make it to where we support

0:04:59.280000 --> 0:05:04.020000
 really long cables of like a mile or
 two miles but our electrical source

0:05:04.020000 --> 0:05:08.560000
 is going to be huge, huge electrical
 battery or lots of voltage so that

0:05:08.560000 --> 0:05:10.300000
 it goes that far.

0:05:10.300000 --> 0:05:13.120000
 Or we could take the
 opposite approach.

0:05:13.120000 --> 0:05:15.720000
 We could design this as a technology
 of, well, it's really only meant

0:05:15.720000 --> 0:05:19.940000
 to connect two devices sitting on a
 table that are like two feet apart

0:05:19.940000 --> 0:05:20.860000
 from each other.

0:05:20.860000 --> 0:05:24.900000
 That way we won't have to use
 very much electrical energy.

0:05:24.900000 --> 0:05:28.960000
 So they decided that based on certain
 ethernet standards, the cables would

0:05:28.960000 --> 0:05:29.660000
 be certain lengths.

0:05:29.660000 --> 0:05:33.580000
 So we'll actually see that coming
 up right here in just a moment.

0:05:33.580000 --> 0:05:37.380000
 But so what I had to
 do with the 543 rule.

0:05:37.380000 --> 0:05:39.720000
 So let's take the original
 implementation of ethernet.

0:05:39.720000 --> 0:05:43.580000
 The original implementation of ethernet
 specified that a single cable

0:05:43.580000 --> 0:05:48.020000
 due to electrical attenuation and everything
 could be no more than about

0:05:48.020000 --> 0:05:54.860000
 185 meters, 185 meters end to end,
 which is actually pretty long.

0:05:54.860000 --> 0:05:59.420000
 But what if you had a really large
 company like a skyscraper of 20 or

0:05:59.420000 --> 0:06:04.560000
 30 stories? One cable of 185
 meters wouldn't cut it.

0:06:04.560000 --> 0:06:06.340000
 You needed something
 longer than that.

0:06:06.340000 --> 0:06:09.400000
 So that's when they invented ethernet
 hubs or ethernet repeaters where

0:06:09.400000 --> 0:06:10.920000
 you could repeat the signal.

0:06:10.920000 --> 0:06:14.560000
 The idea with the repeater was, okay,
 when the signal comes in, strengthen

0:06:14.560000 --> 0:06:21.920000
 it, refresh it and then send it out on another
 185 meters of cable, potentially.

0:06:21.920000 --> 0:06:24.080000
 Well, here's the problem though.

0:06:24.080000 --> 0:06:29.640000
 Is that imagine I have all these cables
 with repeater, repeater, repeater.

0:06:29.640000 --> 0:06:33.940000
 The way the repeater works is that the
 repeater, just like the net card

0:06:33.940000 --> 0:06:39.040000
 on your laptop or PC, is listening to
 that cable and it's listening for

0:06:39.040000 --> 0:06:45.640000
 this preamble. And the first five to
 maybe six bits of the preamble are

0:06:45.640000 --> 0:06:50.300000
 sort of like ignored while the repeater
 says, okay, I think that's something.

0:06:50.300000 --> 0:06:51.800000
 Yes, okay, that's
 a one and a zero.

0:06:51.800000 --> 0:06:54.620000
 So by the time the repeater
 says, yeah, I got it.

0:06:54.620000 --> 0:06:56.460000
 That's a one and a zero coming in.


0:06:56.460000 --> 0:06:59.680000
 The first five or six bits of that
 preamble have been what they called

0:06:59.680000 --> 0:07:02.900000
 consumed. It's sort
 of been dropped off.

0:07:02.900000 --> 0:07:06.240000
 And so now when the repeater is taking
 that fame and copying it and repeating

0:07:06.240000 --> 0:07:10.360000
 it, it can only copy and repeat
 what it could record.

0:07:10.360000 --> 0:07:13.700000
 So if it wasn't able to recognize those
 first five or six bits at the

0:07:13.700000 --> 0:07:17.040000
 front end, it can't copy
 and repeat them.

0:07:17.040000 --> 0:07:20.140000
 So now you've got a frame that came in
 and now the one that's being repeated

0:07:20.140000 --> 0:07:24.120000
 is a tiny little bit shorter because
 the first five or six bits of the

0:07:24.120000 --> 0:07:26.040000
 preamble were sort of wiped out.

0:07:26.040000 --> 0:07:27.760000
 It couldn't really see those.

0:07:27.760000 --> 0:07:31.720000
 Now, if I've got lots of repeaters,
 one after the other, what does that

0:07:31.720000 --> 0:07:35.540000
 mean? That means that preamble is getting
 shorter and shorter and shorter

0:07:35.540000 --> 0:07:38.860000
 and shorter and you run the risk that
 by the time that ethanate frame

0:07:38.860000 --> 0:07:43.540000
 gets to the destination, the preamble
 might not be long enough for the

0:07:43.540000 --> 0:07:47.960000
 destination to lock onto it and be able
 to actually start sampling that

0:07:47.960000 --> 0:07:51.160000
 frame. It might miss the frame entirely
 because there weren't enough preamble

0:07:51.160000 --> 0:07:55.580000
 bits left because all these long string
 of repeaters consumed them one

0:07:55.580000 --> 0:07:57.180000
 after the other.

0:07:57.180000 --> 0:08:01.060000
 So the 543 rule was designed
 to solve that problem.

0:08:01.060000 --> 0:08:02.980000
 They said, okay, here's
 what we're going to do.

0:08:02.980000 --> 0:08:07.640000
 Our rule is going to state that you
 can have a maximum of five segments.

0:08:07.640000 --> 0:08:11.840000
 That's it. No more than five segments
 end to end and then you're done.

0:08:11.840000 --> 0:08:16.440000
 Those five segments can be connected
 by no more than four repeaters or

0:08:16.440000 --> 0:08:21.560000
 four hubs. And only three of those five
 segments can actually have hosts

0:08:21.560000 --> 0:08:26.120000
 on them. Two of them should just be used
 for transport, repeater to repeater,

0:08:26.120000 --> 0:08:27.260000
 nothing in the middle.

0:08:27.260000 --> 0:08:30.280000
 Three of them can have
 hosts connected to it.

0:08:30.280000 --> 0:08:35.300000
 So that was the 543 rule and it was
 all designed to avoid the situation

0:08:35.300000 --> 0:08:37.800000
 of what I just described.

0:08:37.800000 --> 0:08:42.360000
 But that was with coaxial cable,
 cable that was only 185 meters.

0:08:42.360000 --> 0:08:45.760000
 With today's ethanate, that's not
 so much of a big deal anymore.

0:08:45.760000 --> 0:08:49.740000
 But just in case you ever came across
 that term, the 543 rule, I want

0:08:49.740000 --> 0:08:52.300000
 you to know what it
 was talking about.

0:08:52.300000 --> 0:08:55.920000
 Okay, so that's the preamble and
 the start of frame delimiter.

0:08:55.920000 --> 0:09:05.640000
 The next field, actually the next two
 fields, go to something called the

0:09:05.640000 --> 0:09:10.380000
 addressing fields, which is
 what's called a MAC address.

0:09:10.380000 --> 0:09:15.760000
 So Dr. Metcalf and his friends, when
 they were designing the ethanate

0:09:15.760000 --> 0:09:20.400000
 frame, they said, okay, this is going
 to be a technology where there's

0:09:20.400000 --> 0:09:22.600000
 multiple devices tapped
 into a wire.

0:09:22.600000 --> 0:09:26.140000
 Remember, the original ethanate was this
 big long coaxial cable stretching

0:09:26.140000 --> 0:09:31.200000
 down a hallway, going up and down through
 floors and all these Alto Xerox

0:09:31.200000 --> 0:09:34.180000
 PCs were physically
 tapped into it.

0:09:34.180000 --> 0:09:39.060000
 So the idea was, okay, if I have multiple
 devices on this wire, if device

0:09:39.060000 --> 0:09:43.840000
 A wants to send something to device B,
 device B needs to have an address.

0:09:43.840000 --> 0:09:47.780000
 We need to have some way of saying,
 hey, this frame is for you, all the

0:09:47.780000 --> 0:09:51.940000
 other devices in the wire that are also
 going to see the electrical energy,

0:09:51.940000 --> 0:09:55.460000
 it's not for you, ignore
 it, it's for PCB.

0:09:55.460000 --> 0:09:59.400000
 So they said, okay, that is a
 media access control address.

0:09:59.400000 --> 0:10:02.200000
 In other words, how do
 we access the media?

0:10:02.200000 --> 0:10:06.160000
 Media access control address,
 a MAC address.

0:10:06.160000 --> 0:10:11.640000
 So the MAC address, they decided was
 going to be 48 bits long, so 48 bits

0:10:11.640000 --> 0:10:17.260000
 end to end. And while laptops and PCs
 and everything see that as a binary

0:10:17.260000 --> 0:10:20.580000
 number, of course, we as human beings
 can't deal with binaries, we have

0:10:20.580000 --> 0:10:22.840000
 to translate that into
 something we can use.

0:10:22.840000 --> 0:10:26.900000
 And so we see that represent
 as hexadecimal numbers.

0:10:26.900000 --> 0:10:32.380000
 Now in the event that you have never
 worked with hexadecimal before, let's

0:10:32.380000 --> 0:10:34.740000
 just do a quick tutorial on that.

0:10:34.740000 --> 0:10:37.500000
 And if you're already familiar with
 hexadecimal, you can fast-frode the

0:10:37.500000 --> 0:10:42.240000
 video past this section.

0:10:42.240000 --> 0:10:46.060000
 So to explain hexadecimal, I briefly
 want to go back to something that

0:10:46.060000 --> 0:10:49.520000
 you already know,
 which is decimal.

0:10:49.520000 --> 0:10:52.620000
 So any numbers divide up
 by placeholders, right?

0:10:52.620000 --> 0:10:55.380000
 If I have a three digit number, that
 means I've got a placeholder for

0:10:55.380000 --> 0:11:01.100000
 three digits. And the value of those
 digits depends on the value of the

0:11:01.100000 --> 0:11:05.380000
 placeholder. So for example, this right
 here, this placeholder, if we're

0:11:05.380000 --> 0:11:07.260000
 talking about decimal,
 is the ones position.

0:11:07.260000 --> 0:11:12.940000
 I can put a number from zero to nine
 there, and that is the ones position.

0:11:12.940000 --> 0:11:16.400000
 So I could put the number, for example,
 seven, and that means seven times

0:11:16.400000 --> 0:11:24.880000
 one. Now if we're talking decimal,
 which is base 10, that means every

0:11:24.880000 --> 0:11:28.740000
 subsequent placeholder
 is a multiplier of 10.

0:11:28.740000 --> 0:11:32.780000
 So we take the previous one, multiply
 it by 10, that gives us the tens

0:11:32.780000 --> 0:11:40.040000
 position. So if I put another seven here,
 that means seven times 10, instead

0:11:40.040000 --> 0:11:41.420000
 of seven times one.

0:11:41.420000 --> 0:11:45.700000
 And then we multiply that by 10
 again, and we get the hundreds.

0:11:45.700000 --> 0:11:53.400000
 So now we've got 700 plus
 70 plus seven, 777.

0:11:53.400000 --> 0:11:55.220000
 So that's decimal.

0:11:55.220000 --> 0:12:02.320000
 Now if we're talking about hexadecimal,
 we still have placeholders.

0:12:02.320000 --> 0:12:10.520000
 But hexadecimal is a base 16
 counting system, base 16.

0:12:10.520000 --> 0:12:13.880000
 So the first placeholder is
 still the ones position.

0:12:13.880000 --> 0:12:15.920000
 That doesn't change.

0:12:15.920000 --> 0:12:17.560000
 But here's what's different.

0:12:17.560000 --> 0:12:29.020000
 In a base 10 system, each placeholder
 could have a single digit ranging

0:12:29.020000 --> 0:12:31.940000
 from zero to zero.

0:12:31.940000 --> 0:12:37.440000
 To nine. There were 10 different combinations
 that could be placed in

0:12:37.440000 --> 0:12:38.960000
 each one of these digits.

0:12:38.960000 --> 0:12:41.340000
 In each one of these placeholders.


0:12:41.340000 --> 0:12:53.860000
 Well in hexadecimal, each placeholder
 could have a single digit ranging

0:12:53.860000 --> 0:13:00.440000
 from zero to F. You
 say F, what's that?

0:13:00.440000 --> 0:13:10.160000
 Well in hexadecimal, you still start
 out with your decimal digits, zero

0:13:10.160000 --> 0:13:12.700000
 through nine. That only
 gives us 10 digits.

0:13:12.700000 --> 0:13:14.000000
 And this is a base 16.

0:13:14.000000 --> 0:13:17.380000
 We need 16 things, 16 digits.

0:13:17.380000 --> 0:13:23.620000
 So now we start going into letters
 A, B, C, D, E, and F.

0:13:23.620000 --> 0:13:30.620000
 So in hexadecimal, A would be the equivalent
 of 10 in decimal, B would

0:13:30.620000 --> 0:13:32.520000
 be the equivalent of 11.

0:13:32.520000 --> 0:13:34.640000
 C would be the equivalent of 12.

0:13:34.640000 --> 0:13:39.280000
 And if we keep going on up,
 F is the equivalent of 15.

0:13:39.280000 --> 0:13:44.100000
 So in a single placeholder here,
 I could have from zero to F.

0:13:44.100000 --> 0:13:52.000000
 So if I put, let's say, A right here,
 well we know that's A times one,

0:13:52.000000 --> 0:13:54.080000
 well A is really the
 number 10 in decimal.

0:13:54.080000 --> 0:13:56.900000
 So that's 10 times one, that's 10.


0:13:56.900000 --> 0:14:06.620000
 If I put, let's say, three right here,
 well in decimal, we multiplied

0:14:06.620000 --> 0:14:11.200000
 by 10. Each placeholder was a multiple
 of 10 from the previous placeholder.

0:14:11.200000 --> 0:14:14.600000
 Well in hexadecimal, we're
 talking about base 16.

0:14:14.600000 --> 0:14:20.000000
 So we multiply by 16, so we got one times
 16, which is the 16's position.

0:14:20.000000 --> 0:14:28.660000
 The next position is going to be
 16 times 16, which is the 256's.

0:14:28.660000 --> 0:14:37.520000
 So 3A in hexadecimal is 3 times 16,
 which is 48, plus 10, plus A times

0:14:37.520000 --> 0:14:38.440000
 one, which is 10.

0:14:38.440000 --> 0:14:42.000000
 So 48 plus 10, this is 58.

0:14:42.000000 --> 0:14:45.600000
 So the hexadecimal number, hexadecimals
 are usually represented as zero

0:14:45.600000 --> 0:14:47.100000
 X, but not always.

0:14:47.100000 --> 0:14:55.880000
 So zero X3A in hexadecimal
 is equal to 58 in decimal.

0:14:55.880000 --> 0:15:05.200000
 If I put a 2 right here, that'd be
 256 times 2, plus 16 times 3, plus

0:15:05.200000 --> 0:15:10.640000
 10 times 1. So why do
 they do it this way?

0:15:10.640000 --> 0:15:20.660000
 Well when it comes to MAC addresses,
 I'm not going to do all of it, but

0:15:20.660000 --> 0:15:25.500000
 what have we got here?

0:15:25.500000 --> 0:15:33.040000
 So right now, 8 times 4, so this is
 32 bits right now, out of my 48.

0:15:33.040000 --> 0:15:38.620000
 So if this was the first 32 bits of
 my 48-bit MAC address, and I want

0:15:38.620000 --> 0:15:42.440000
 to represent this in some way that
 was meaningful, they decide to use

0:15:42.440000 --> 0:15:47.520000
 hexadecimal. So they said every 4 bits is
 going to be represented by hexadecimal

0:15:47.520000 --> 0:15:51.320000
 character. So that number right
 there, 0010 and binary.

0:15:51.320000 --> 0:15:55.720000
 If that were a decimal number,
 that'd be the number 2.

0:15:55.720000 --> 0:16:01.440000
 Well we know that in hexadecimal,
 2 is the same, it's still 2.

0:16:01.440000 --> 0:16:08.060000
 In binary, 1111, what
 is that in decimal?

0:16:08.060000 --> 0:16:11.140000
 Wasn't that the number 15?

0:16:11.140000 --> 0:16:18.360000
 8 plus 4 plus 2 plus 1 is 15,
 but in hexadecimal, 15 is F.

0:16:18.360000 --> 0:16:26.540000
 This here's the number 1, this here's
 the number 13, so it'll be D.

0:16:26.540000 --> 0:16:35.160000
 So your MAC addresses are always going
 to be represented like this.

0:16:35.160000 --> 0:16:38.940000
 The 48 bits in binary are going to be
 showing up to you in whatever show

0:16:38.940000 --> 0:16:43.900000
 command you use as a
 hexadecimal number.

0:16:43.900000 --> 0:16:50.160000
 So for example, here's an example of
 a MAC address, aaaa.aaaa, so on and

0:16:50.160000 --> 0:16:55.860000
 so forth. Now depending on the device
 you're on, they will sometimes display

0:16:55.860000 --> 0:16:59.700000
 MAC addresses differently, some devices
 will show MAC addresses like this.

0:16:59.700000 --> 0:17:08.360000
 For every 4 characters, hex characters,
 it'll be separated by a dot.

0:17:08.360000 --> 0:17:15.620000
 Sometimes that same thing will be separated
 by colons, sometimes every

0:17:15.620000 --> 0:17:21.260000
 2 will be separated by colons, it just
 depends on the device that you're

0:17:21.260000 --> 0:17:27.660000
 on. The main thing is, is that these
 are hexadecimal characters and they

0:17:27.660000 --> 0:17:35.760000
 add up to a total of
 48 bits in binary.

0:17:35.760000 --> 0:17:42.300000
 So of our MAC address, the first half
 of it, the first 24 bits is what's

0:17:42.300000 --> 0:17:45.480000
 called an organizationally
 unique identifier.

0:17:45.480000 --> 0:17:46.980000
 What's that mean?

0:17:46.980000 --> 0:17:51.760000
 Let's say for example that I had a machine
 shop in my garage and I thought,

0:17:51.760000 --> 0:17:55.480000
 you know what? I have all the equipment
 necessary to create my own Ethernet

0:17:55.480000 --> 0:17:59.940000
 adapters. I want to start making my
 own Ethernet adapters and sell them

0:17:59.940000 --> 0:18:04.080000
 on the open market and compete against
 Intel and some of these other big

0:18:04.080000 --> 0:18:09.680000
 companies. In order to do that, all
 of the adapters that I create in my

0:18:09.680000 --> 0:18:14.580000
 garage and my machine shop, the first half
 of them have to have an organizationally

0:18:14.580000 --> 0:18:18.760000
 unique identifier that is
 unique to my organization.

0:18:18.760000 --> 0:18:19.440000
 So what would I do?

0:18:19.440000 --> 0:18:23.180000
 Well, I would go to the IEEE and I'd
 pay them something like 500 American

0:18:23.180000 --> 0:18:25.000000
 dollars or something like that.

0:18:25.000000 --> 0:18:29.500000
 And once I pay them some money,
 they will give me an OUI.

0:18:29.500000 --> 0:18:33.880000
 And now every single NIC card that I
 create in my machine shop will have

0:18:33.880000 --> 0:18:36.040000
 my OUI at the front half.

0:18:36.040000 --> 0:18:37.600000
 They will all have
 the same number.

0:18:37.600000 --> 0:18:41.460000
 And then the second half of the address,
 as you can see here, will be

0:18:41.460000 --> 0:18:48.060000
 unique. So every single NIC card should
 have its own unique MAC address

0:18:48.060000 --> 0:18:52.420000
 burned into it at the time of manufacture
 that is unchanging.

0:18:52.420000 --> 0:18:56.560000
 So the manufacturer's stamp, the OUI
 will be the first half and then the

0:18:56.560000 --> 0:19:01.780000
 second half will be a unique number
 just for that MAC address, just for

0:19:01.780000 --> 0:19:09.000000
 that NIC card. And you can see here,
 if you're curious, I have up here,

0:19:09.000000 --> 0:19:35.800000
 you can go to this website,
 wireshark.org.

0:19:35.800000 --> 0:19:38.600000
 00.00.00c. Who owns that?

0:19:38.600000 --> 0:19:43.700000
 Search. Cisco. Cisco
 owns that one.

0:19:43.700000 --> 0:19:46.900000
 You can type in, you know, you can look
 at the OUI of your own NIC card

0:19:46.900000 --> 0:19:48.980000
 on your laptop or your PC.

0:19:48.980000 --> 0:19:53.220000
 Maybe you own 00.002.11.

0:19:53.220000 --> 0:19:55.300000
 Does anybody own that?

0:19:55.300000 --> 0:19:58.040000
 Nature Worldwide Technology
 Corporation.

0:19:58.040000 --> 0:20:01.060000
 So this is kind of a, and there are
 other websites that do the same type

0:20:01.060000 --> 0:20:04.220000
 of thing where you can plug in an OUI
 and it will tell you what company

0:20:04.220000 --> 0:20:13.220000
 owns that OUI. But we're not done
 with the MAC address just yet.

0:20:13.220000 --> 0:20:20.840000
 So the MAC address here, we know that
 this is the first 24 bits, first

0:20:20.840000 --> 0:20:25.900000
 3 bytes. Let me go back to the
 whiteboard here for a moment.

0:20:25.900000 --> 0:20:29.120000
 So let's say this was my MAC address,
 this is the first 32 bits of my

0:20:29.120000 --> 0:20:32.480000
 MAC address. Let me get
 rid of some of this.

0:20:32.480000 --> 0:20:38.700000
 Well, the first byte is this.

0:20:38.700000 --> 0:20:41.360000
 That's the first byte,
 the first 8 bits.

0:20:41.360000 --> 0:20:48.880000
 In every MAC address, in the first byte,
 this least significant bit right

0:20:48.880000 --> 0:20:51.620000
 here. I'll put a little
 box around that.

0:20:51.620000 --> 0:20:54.580000
 That bit has a special meaning.

0:20:54.580000 --> 0:21:03.820000
 That is called the individual
 slash group bit.

0:21:03.820000 --> 0:21:12.280000
 If that bit is a zero, that means this
 MAC address belongs to an individual

0:21:12.280000 --> 0:21:17.780000
 device. This is a unique MAC address
 that doesn't belong to anybody else.

0:21:17.780000 --> 0:21:20.580000
 Clearly, this one is not a zero.

0:21:20.580000 --> 0:21:26.640000
 If it's a one, that means this
 MAC address is a group address.

0:21:26.640000 --> 0:21:30.160000
 You might be wondering, what do
 you mean by a group address?

0:21:30.160000 --> 0:21:32.640000
 Well, think of the concept
 of a broadcast.

0:21:32.640000 --> 0:21:34.060000
 What is a broadcast?

0:21:34.060000 --> 0:21:38.460000
 A broadcast is I put one data unit on
 the wire and it's meant for everybody

0:21:38.460000 --> 0:21:43.500000
 to see. Well, if I'm going to put that
 data unit into an Ethernet frame,

0:21:43.500000 --> 0:21:47.460000
 the destination MAC address of that
 frame has to indicate this is not

0:21:47.460000 --> 0:21:50.760000
 for anybody in particular,
 this is for everybody.

0:21:50.760000 --> 0:22:04.520000
 Well, the broadcast MAC
 address looks like this.

0:22:04.520000 --> 0:22:09.200000
 Or in binary, it's just
 48 bits of all ones.

0:22:09.200000 --> 0:22:11.040000
 That is the broadcast MAC address.


0:22:11.040000 --> 0:22:13.480000
 And you can see here that if we actually
 convert that into binary, which

0:22:13.480000 --> 0:22:19.840000
 I did, and I take a look at the first
 byte, 1, 2, 3, 4, 1, 2, 3, 4, I

0:22:19.840000 --> 0:22:21.900000
 think I've got all
 four of them there.

0:22:21.900000 --> 0:22:28.000000
 We can see here that the individual
 group bit is set to a one, because

0:22:28.000000 --> 0:22:29.800000
 that is a group address.

0:22:29.800000 --> 0:22:33.960000
 If you have any experience with multicasts
 at layer two, there are special

0:22:33.960000 --> 0:22:36.000000
 MAC addresses for multicasts.

0:22:36.000000 --> 0:22:38.040000
 Those are also group addresses.

0:22:38.040000 --> 0:22:42.040000
 So their least significant bit will
 also be turned on as a one.

0:22:42.040000 --> 0:22:45.540000
 So any MAC address that has a one bit
 here means it does not belong to

0:22:45.540000 --> 0:22:47.080000
 a specific NIC card.

0:22:47.080000 --> 0:22:50.460000
 It belongs to a group of devices.

0:22:50.460000 --> 0:22:53.420000
 That is the individual group bit.

0:22:53.420000 --> 0:23:03.640000
 Now, in addition to that, the bit right
 next to it, right here, that bit

0:23:03.640000 --> 0:23:04.840000
 also has a special significance.

0:23:04.840000 --> 0:23:14.260000
 That's called the universal
 or global local bit.

0:23:14.260000 --> 0:23:23.040000
 If that is a zero, that means this address
 is universally slash globally

0:23:23.040000 --> 0:23:29.160000
 unique. That means nobody else in the
 entire world should have that MAC

0:23:29.160000 --> 0:23:31.280000
 address. It belongs to you.

0:23:31.280000 --> 0:23:36.780000
 It is yours. Now, if I was to go into
 a device and change its MAC address,

0:23:36.780000 --> 0:23:41.200000
 which you actually can do on most devices,
 there's nothing that forces

0:23:41.200000 --> 0:23:45.000000
 me to do this, but if I'm changing
 my MAC address, what certainty do I

0:23:45.000000 --> 0:23:48.700000
 have that the new MAC address I'm putting
 on there manually isn't already

0:23:48.700000 --> 0:23:50.240000
 out there in the world somewhere.

0:23:50.240000 --> 0:23:51.800000
 That's reserved for somebody else.


0:23:51.800000 --> 0:23:56.160000
 I don't know. So if I change it, I should
 take that second bit and flip

0:23:56.160000 --> 0:24:01.920000
 it to a one, which means that I have
 now a little bit of a memory.

0:24:01.920000 --> 0:24:05.380000
 Now, I created what's called a
 locally administered address.

0:24:05.380000 --> 0:24:08.480000
 I mean, this MAC address is not the
 MAC address that was burned on here

0:24:08.480000 --> 0:24:11.580000
 from the manufacturer has
 been locally modified.

0:24:11.580000 --> 0:24:15.640000
 No guarantees anymore that
 this MAC address is unique.

0:24:15.640000 --> 0:24:19.200000
 So those two bits have
 special meaning there.

0:24:19.200000 --> 0:24:25.380000
 And that's what this slide
 is referring to.

0:24:25.380000 --> 0:24:30.220000
 All right. So within the Ethernet frame,
 Ethernet version two, after our

0:24:30.220000 --> 0:24:34.180000
 MAC addresses, after we have a destination
 MAC and a source MAC, we have

0:24:34.180000 --> 0:24:36.440000
 a type field, two bytes long.

0:24:36.440000 --> 0:24:41.320000
 And this indicates what type of upper
 layer data is this carrying, some

0:24:41.320000 --> 0:24:46.480000
 common type codes you might see.

0:24:46.480000 --> 0:24:48.800000
 I'll just say them verbally
 here to you.

0:24:48.800000 --> 0:24:49.860000
 Actually, let's see here.

0:24:49.860000 --> 0:24:52.080000
 Do I have a way of doing this?

0:24:52.080000 --> 0:24:58.980000
 No, not let me do it.

0:24:58.980000 --> 0:25:06.940000
 Okay. Okay. Okay.

0:25:06.940000 --> 0:25:11.380000
 So if the type code you see is, actually,
 I want to go ahead and type

0:25:11.380000 --> 0:25:21.180000
 this out. Here's some
 common ether types.

0:25:21.180000 --> 0:25:25.180000
 These are probably the three most
 common ones that you'll ever see.

0:25:25.180000 --> 0:25:34.760000
 0x800. That means this Ethernet frame
 is carrying an IP version four packet.

0:25:34.760000 --> 0:25:40.000000
 0x806 means it's carrying an ARP, either
 an ARP request or an ARP response.

0:25:40.000000 --> 0:25:47.380000
 And 0x86DD means we're carrying
 an IPV6 packet.

0:25:47.380000 --> 0:25:51.520000
 There are many, many
 other ones as well.

0:25:51.520000 --> 0:25:57.300000
 And if you're curious about those, you
 can go to this website right here.

0:25:57.300000 --> 0:26:00.380000
 Go ahead and make this a little
 bit larger so you can see it.

0:26:00.380000 --> 0:26:07.700000
 kbear.com. Archive, kbear,
 ethernet, slash type.

0:26:07.700000 --> 0:26:11.000000
 You can pause this video for a moment
 if you want to write that down.

0:26:11.000000 --> 0:26:12.720000
 There are other websites
 that do this as well.

0:26:12.720000 --> 0:26:16.220000
 You can just Google Ethernet
 type value or type code.

0:26:16.220000 --> 0:26:21.020000
 And from here you can see all the different
 type values and what they've

0:26:21.020000 --> 0:26:22.520000
 been assigned to.

0:26:22.520000 --> 0:26:32.260000
 Now with the 802.3 frame, they decide
 to change that into a length field.

0:26:32.260000 --> 0:26:38.200000
 And the length field that says how long
 is this yellow portion here, our

0:26:38.200000 --> 0:26:42.880000
 802.2 header and our data.

0:26:42.880000 --> 0:26:46.500000
 So I'm going to talk a little bit more
 about this as we, when we get into

0:26:46.500000 --> 0:26:50.580000
 the section about the size of Ethernet
 frames and what are meant by runts

0:26:50.580000 --> 0:26:52.340000
 and giants and things like that.

0:26:52.340000 --> 0:26:58.920000
 But for now, the Ethernet specification
 says, then Ethernet frame, that

0:26:58.920000 --> 0:27:03.400000
 the data of an Ethernet frame should
 be a minimum of 46 bytes in size

0:27:03.400000 --> 0:27:07.780000
 up to a maximum of
 1500 bytes in size.

0:27:07.780000 --> 0:27:13.000000
 46 to 1500. That being the case, sometimes
 the question arises, okay,

0:27:13.000000 --> 0:27:16.900000
 well after my source address, how does
 the net card that's receiving this

0:27:16.900000 --> 0:27:21.160000
 frame know if the next two bytes are
 a type value or a length value?

0:27:21.160000 --> 0:27:22.480000
 How does it know?

0:27:22.480000 --> 0:27:24.000000
 Well, here's how it knows.

0:27:24.000000 --> 0:27:31.040000
 All of the valid type codes are values
 that in decimal are greater than

0:27:31.040000 --> 0:27:33.700000
 or equal to 1536.

0:27:33.700000 --> 0:27:36.780000
 You might say 1536,
 what about 1501?

0:27:36.780000 --> 0:27:42.060000
 Well, actually the values of 1501
 through 1535 are undefined.

0:27:42.060000 --> 0:27:44.200000
 They are sort of left
 there for future use.

0:27:44.200000 --> 0:27:51.260000
 But the type values of 1536 and above
 are used for ARP and IPv4 and IPv6

0:27:51.260000 --> 0:28:02.540000
 and all those things in that
 list I just showed you.

0:28:02.540000 --> 0:28:03.340000
 So, what does that ever be?

0:28:03.340000 --> 0:28:10.440000
 Greater than 1500 because 1500 is
 the maximum size of the frame.

0:28:10.440000 --> 0:28:15.440000
 Now, for talking about 802.3, you might
 have been thinking, well, if we

0:28:15.440000 --> 0:28:20.080000
 didn't have a type field, how does
 the receiving device know what the

0:28:20.080000 --> 0:28:24.700000
 data is? If it should go to the IPv4
 process, or the IPv6 process, or

0:28:24.700000 --> 0:28:30.420000
 if it should go to ARP, well, this is
 where the 802.2 working group came

0:28:30.420000 --> 0:28:33.360000
 into play. Remember, 802.2 was the
 working group that came up with the

0:28:33.360000 --> 0:28:38.620000
 logical link control, that upper
 sublayer of the data link layer.

0:28:38.620000 --> 0:28:42.960000
 And they said, okay, we're going
 to put three subfields in here.

0:28:42.960000 --> 0:28:47.060000
 These three subfields comprise
 your logical link control.

0:28:47.060000 --> 0:28:52.260000
 DSAAP stands for destination
 service access point.

0:28:52.260000 --> 0:28:54.500000
 Destination service access point.

0:28:54.500000 --> 0:28:57.240000
 It's basically the exact same
 thing as a type code.

0:28:57.240000 --> 0:29:02.280000
 It's a value. And there's certain DSAAP
 values for IPv4, IPv6, and all

0:29:02.280000 --> 0:29:04.100000
 sorts of other stuff too.

0:29:04.100000 --> 0:29:10.220000
 SSAAP, as you can probably guess,
 is source service access point.

0:29:10.220000 --> 0:29:12.120000
 Usually these two values
 are the same.

0:29:12.120000 --> 0:29:18.180000
 Whatever the protocol number was that
 created this field at the source

0:29:18.180000 --> 0:29:22.960000
 is going to be talking to the exact
 same protocol at the destination.

0:29:22.960000 --> 0:29:26.480000
 It's not always the same, but the vast
 majority of time, these two numbers

0:29:26.480000 --> 0:29:29.300000
 are the same. The control field.

0:29:29.300000 --> 0:29:33.180000
 In modern day implementations of Ethernet,
 the control field really isn't

0:29:33.180000 --> 0:29:34.720000
 used for anything.

0:29:34.720000 --> 0:29:40.840000
 But what this is for is because remember,
 LLC, the 802.2 working group,

0:29:40.840000 --> 0:29:43.360000
 didn't create LLC
 just for Ethernet.

0:29:43.360000 --> 0:29:47.480000
 They said, we want lots of different
 types of layer two protocols to make

0:29:47.480000 --> 0:29:54.640000
 use of LLC. So they said, okay, well, we
 want LLC to be used in some protocols

0:29:54.640000 --> 0:29:58.860000
 that layer two are connection
 oriented.

0:29:58.860000 --> 0:30:02.920000
 So for example, LLC designs basically
 what's called three different types

0:30:02.920000 --> 0:30:07.500000
 of services. There's what's called
 unacknowledged connectionless mode

0:30:07.500000 --> 0:30:09.560000
 that's like Ethernet.

0:30:09.560000 --> 0:30:12.800000
 When you send out an Ethernet frame,
 do you get an acknowledgment back

0:30:12.800000 --> 0:30:25.700000
 for it? No you don't.

0:30:25.700000 --> 0:30:29.060000
 So Ethernet is unacknowledged connectionless
 mode, which means the control

0:30:29.060000 --> 0:30:31.600000
 field really doesn't do anything.

0:30:31.600000 --> 0:30:35.340000
 But if you're using another type of
 layer two protocol off the top of

0:30:35.340000 --> 0:30:36.760000
 my head, I can't think
 of what they would be.

0:30:36.760000 --> 0:30:40.820000
 Maybe some like mainframe
 IBM SNA type protocols.

0:30:40.820000 --> 0:30:45.620000
 You might have connection mode, which means
 you actually establish a connection

0:30:45.620000 --> 0:30:47.200000
 first. You get acknowledgments
 back.

0:30:47.200000 --> 0:30:49.020000
 So you get the other type of layer
 two protocols that are like TCP at

0:30:49.020000 --> 0:30:50.200000
 the transport layer.

0:30:50.200000 --> 0:30:54.560000
 And there's a third mode called acknowledged
 connectionless mode.

0:30:54.560000 --> 0:30:57.420000
 We actually do get acknowledgments back
 even though you're connectionless.

0:30:57.420000 --> 0:31:00.300000
 I don't know what layer two
 protocols actually use that.

0:31:00.300000 --> 0:31:03.660000
 So if you're using one of those other
 types of layer two protocols, which

0:31:03.660000 --> 0:31:07.740000
 I don't know what they are, that are either
 doing connection mode or acknowledged

0:31:07.740000 --> 0:31:11.680000
 connectionless mode, that's when the
 control field would actually take

0:31:11.680000 --> 0:31:13.020000
 on significance.

0:31:13.020000 --> 0:31:15.500000
 But in the world of Ethernet, it
 doesn't really mean anything.

0:31:15.500000 --> 0:31:17.100000
 Doesn't do anything.

0:31:17.100000 --> 0:31:26.020000
 And at the end, we have a trailer, which
 consists of our frame check sequence.

0:31:26.020000 --> 0:31:31.280000
 So this is used for error detection,
 not error correction.

0:31:31.280000 --> 0:31:35.300000
 So the FCS field, so if you receive
 an Ethernet frame by looking at the

0:31:35.300000 --> 0:31:39.620000
 FCS field, you can tell if any of the
 bits in that frame have been modified

0:31:39.620000 --> 0:31:44.940000
 or changed. But you can't tell which
 bits have been modified or changed.

0:31:44.940000 --> 0:31:48.300000
 All you know is that the frame does
 not look the same as when the source

0:31:48.300000 --> 0:31:54.280000
 sent it. So basically the way this
 works is that when the originator,

0:31:54.280000 --> 0:31:58.440000
 the source of the frame, put this frame
 together, it runs a cyclic redundancy

0:31:58.440000 --> 0:32:02.380000
 check, a CRC, which is a special algorithm,
 where it takes all the bits

0:32:02.380000 --> 0:32:06.740000
 starting with the destination address
 all the way through to the end of

0:32:06.740000 --> 0:32:10.160000
 the data. So from the DA, all the way
 to the end of the data, it takes

0:32:10.160000 --> 0:32:13.760000
 all those bits, runs them through an
 algorithm called a cyclic redundancy

0:32:13.760000 --> 0:32:19.280000
 check, which then computes some sort
 of number, like let's say A123, and

0:32:19.280000 --> 0:32:22.380000
 it puts that number into the FCS.

0:32:22.380000 --> 0:32:27.520000
 So the idea is, when I send you this
 frame, you're going to take the exact

0:32:27.520000 --> 0:32:31.820000
 same bits from the destination address
 to the end of the data, and you're

0:32:31.820000 --> 0:32:35.320000
 going to run it through the exact
 same cyclic redundancy check.

0:32:35.320000 --> 0:32:38.720000
 And you're going to compare the number
 that you came up with, with the

0:32:38.720000 --> 0:32:40.440000
 number that's in the FCS here.

0:32:40.440000 --> 0:32:44.600000
 Now if you come up with A123 and
 it matches this, you say, great!

0:32:44.600000 --> 0:32:48.160000
 Clearly none of these bits have been
 modified, because if they did, your

0:32:48.160000 --> 0:32:51.740000
 cyclic redundancy check would not
 come up with the same number.

0:32:51.740000 --> 0:32:56.160000
 And if that happened, that would be
 considered an FCS or a CRC error,

0:32:56.160000 --> 0:32:57.900000
 and you would just simply
 throw away the frame.

0:32:57.900000 --> 0:33:00.340000
 There's no way to figure
 out what changed.

0:33:00.340000 --> 0:33:02.660000
 All you know is that that frame
 is no longer reliable.

0:33:02.660000 --> 0:33:04.300000
 Something has been modified.

0:33:04.300000 --> 0:33:06.560000
 There has been an error.

0:33:06.560000 --> 0:33:11.740000
 So that concludes this section on the
 various fields and components of

0:33:11.740000 --> 0:33:13.100000
 the Ethernet frame.

0:33:13.100000 --> 0:33:16.200000
 In the next section, we're going to look
 at Ethernet frame sizes and talk

0:33:16.200000 --> 0:33:19.640000
 about things like Runtz,
 Giants, and Jumbo frames.