WEBVTT

0:00:07.540000 --> 0:00:11.440000
 This video, which is part of the CCT
 routing and switching series, is

0:00:11.440000 --> 0:00:16.120000
 called Telco termination
 points and CSU DSUs.

0:00:16.120000 --> 0:00:21.520000
 My name is Keith Bogart and I will be
 your instructor for this session.

0:00:21.520000 --> 0:00:25.400000
 In this session I'm going to cover two
 of the bullet points that are in

0:00:25.400000 --> 0:00:30.000000
 the CCT routing and switching Blueprint
 under section 3.0, namely the

0:00:30.000000 --> 0:00:34.320000
 bullets that read described Telco termination
 points such as DMARC and

0:00:34.320000 --> 0:00:41.500000
 etc. And describe what a CSU does,
 such as loopback processes and etc.

0:00:41.500000 --> 0:00:46.300000
 So let's go into Telco terminology
 briefly to talk about these various

0:00:46.300000 --> 0:00:48.100000
 different terms.

0:00:48.100000 --> 0:00:53.220000
 So the idea here at a high level is
 that you have gone to a telephone

0:00:53.220000 --> 0:00:59.660000
 company and you are getting a digital
 circuit from that telephone company.

0:00:59.660000 --> 0:01:01.560000
 So let's go back in
 time a little bit.

0:01:01.560000 --> 0:01:06.060000
 I know that now as I record this in 2017,
 most of the time you don't have

0:01:06.060000 --> 0:01:07.220000
 to go to a Telco anymore.

0:01:07.220000 --> 0:01:10.520000
 You go directly to an internet service
 provider and you ask for like a

0:01:10.520000 --> 0:01:14.640000
 Metro Ethernet connection or maybe
 a cable or DSL connection.

0:01:14.640000 --> 0:01:19.560000
 But let me take you back about 25 or
 30 years because you'll still see

0:01:19.560000 --> 0:01:25.280000
 this in parts of the world.

0:01:25.280000 --> 0:01:33.300000
 So in those situations we know that
 back in the before the 1950s, so way

0:01:33.300000 --> 0:01:38.880000
 before the invention of TCPIP, when
 you had Telco technology, what was

0:01:38.880000 --> 0:01:42.180000
 it? Well you would pick up
 your phone at your house.

0:01:42.180000 --> 0:01:47.360000
 You had some wires connecting that
 phone that would go a few miles to

0:01:47.360000 --> 0:01:51.660000
 the telephone company's office where
 an actual human being would sit there

0:01:51.660000 --> 0:01:54.280000
 at a switchboard and they
 would switch you.

0:01:54.280000 --> 0:01:58.640000
 Basically they would connect the wires
 coming from your house and they

0:01:58.640000 --> 0:02:02.440000
 would connect it with a cable to another
 port or jack that connected to

0:02:02.440000 --> 0:02:05.100000
 somebody else's house or
 somebody else's business.

0:02:05.100000 --> 0:02:08.160000
 So it was actually running a complete
 circuit between you and whoever

0:02:08.160000 --> 0:02:09.820000
 you were talking up to.

0:02:09.820000 --> 0:02:16.900000
 So every phone conversation consisted
 of a dedicated circuit between point

0:02:16.900000 --> 0:02:21.540000
 A and point B. Even if you were talking
 across the country, that was still

0:02:21.540000 --> 0:02:24.280000
 the case. It had to have
 dedicated wires.

0:02:24.280000 --> 0:02:28.040000
 Well, in the 50s is more and more and
 more people start getting telephones

0:02:28.040000 --> 0:02:30.420000
 and telephones became
 really popular.

0:02:30.420000 --> 0:02:33.280000
 The telephone companies realized,
 uh oh, we have a problem here.

0:02:33.280000 --> 0:02:39.000000
 If I've got, if we've got 10,000 people
 on the east coast talking to 10

0:02:39.000000 --> 0:02:43.480000
,000 people on the west coast, that's
 going to be a lot of wires to connect

0:02:43.480000 --> 0:02:47.360000
 all the way across the country
 to run all those conversations.

0:02:47.360000 --> 0:02:50.360000
 Whoa, if it gets into the hundreds
 of thousands or even the millions.

0:02:50.360000 --> 0:02:55.680000
 So the telephone company can invent
 something called a T1 line.

0:02:55.680000 --> 0:02:59.380000
 T is in Thomas or T1 is in Telco.

0:02:59.380000 --> 0:03:04.260000
 And the idea behind a T1 line was, why
 don't we have one physical line,

0:03:04.260000 --> 0:03:09.020000
 or I should say one cable that's fairly
 thick and shielded really well,

0:03:09.020000 --> 0:03:12.920000
 but we're going to take all of those
 telephone conversations and multiplex

0:03:12.920000 --> 0:03:15.580000
 them onto this one line.

0:03:15.580000 --> 0:03:17.320000
 Now, what do I mean
 by multiplex them?

0:03:17.320000 --> 0:03:19.960000
 The idea of multiplexing
 is very simple.

0:03:19.960000 --> 0:03:21.000000
 Here's the idea.

0:03:21.000000 --> 0:03:26.660000
 Imagine you have 10 people in a
 room and they all want to talk.

0:03:26.660000 --> 0:03:30.220000
 Well, if they all talk at the same time,
 it's just going to be garbage.

0:03:30.220000 --> 0:03:32.900000
 It's gibberish. No one's going to
 be able to understand anybody.

0:03:32.900000 --> 0:03:34.640000
 So the idea of multiplexing
 is this.

0:03:34.640000 --> 0:03:36.300000
 We say, okay, here's what
 we're going to do.

0:03:36.300000 --> 0:03:40.840000
 We're going to take the next hour,
 a time slot, a period of time, and

0:03:40.840000 --> 0:03:42.300000
 we're going to divide it up.

0:03:42.300000 --> 0:03:45.460000
 And each person's going to get
 a unique slice of that time.

0:03:45.460000 --> 0:03:48.660000
 So Tom, you can talk for
 the first five minutes.

0:03:48.660000 --> 0:03:51.100000
 Sally, you get the
 next five minutes.

0:03:51.100000 --> 0:03:52.620000
 John, you get the third
 five minutes.

0:03:52.620000 --> 0:03:54.440000
 And then I'll roll
 back to John again.

0:03:54.440000 --> 0:03:58.080000
 So every five minutes, you guys get
 your own dedicated time slot.

0:03:58.080000 --> 0:04:02.680000
 You can only talk when it's your turn
 or your slot of time to talk.

0:04:02.680000 --> 0:04:06.340000
 And if your turn comes around and you
 have nothing to say, well, we'll

0:04:06.340000 --> 0:04:09.900000
 just sit here and twiddle our thumbs
 for five minutes because maybe you'll

0:04:09.900000 --> 0:04:11.220000
 think of something.

0:04:11.220000 --> 0:04:13.700000
 And then when your five minute time
 period is over, it goes on to the

0:04:13.700000 --> 0:04:18.900000
 next time slot. Same idea was true
 with telco terminology and T1s.

0:04:18.900000 --> 0:04:22.080000
 They say, we're going to take all these
 telephone calls and multiplex

0:04:22.080000 --> 0:04:23.760000
 them onto this T1 line.

0:04:23.760000 --> 0:04:27.240000
 This one phone call, he'll get this tiny
 little slice of time that's repeating,

0:04:27.240000 --> 0:04:28.740000
 repeating, repeating, repeating.

0:04:28.740000 --> 0:04:30.000000
 There'll be another
 telephone call.

0:04:30.000000 --> 0:04:32.600000
 He'll get the slice of time
 right next to that.

0:04:32.600000 --> 0:04:36.320000
 And so now we had instead of multiple
 wires carrying phone calls from

0:04:36.320000 --> 0:04:41.220000
 everybody, we just had one cable that
 was digitally carrying all these

0:04:41.220000 --> 0:04:42.800000
 phone calls on one circuit.

0:04:42.800000 --> 0:04:45.280000
 So that was called a T1 line.

0:04:45.280000 --> 0:04:49.760000
 Well, very soon people start realizing,
 hey, these T1 lines can carry

0:04:49.760000 --> 0:04:52.640000
 a pretty good amount of bandwidth,
 go at a pretty good speed.

0:04:52.640000 --> 0:04:56.280000
 I'd like to actually have a T1 line
 run all the way to my business.

0:04:56.280000 --> 0:05:01.140000
 If I have a T1 line going all the way
 to my company, then I can get a

0:05:01.140000 --> 0:05:05.140000
 much faster connection to the internet
 than if I'm just using a dial up

0:05:05.140000 --> 0:05:06.940000
 modem or something like that.

0:05:06.940000 --> 0:05:10.020000
 So that's where we are in
 this slide right here.

0:05:10.020000 --> 0:05:13.760000
 So we're talking about the telephone
 company running a wire to your house,

0:05:13.760000 --> 0:05:18.300000
 which is carrying a T1, the same type
 of T1 that they're using between

0:05:18.300000 --> 0:05:19.440000
 their buildings.

0:05:19.440000 --> 0:05:21.460000
 So what's the terminology
 of all this?

0:05:21.460000 --> 0:05:25.440000
 Let's start with a term of CPE.

0:05:25.440000 --> 0:05:30.500000
 So you're going to have to have some
 equipment in your house or in your

0:05:30.500000 --> 0:05:34.900000
 business that connects to this line
 that is your responsibility.

0:05:34.900000 --> 0:05:38.580000
 If this equipment fails, you're
 responsible for replacing it.

0:05:38.580000 --> 0:05:41.980000
 If you want to get something bigger, better,
 faster, it's your responsibility

0:05:41.980000 --> 0:05:43.120000
 for replacing it.

0:05:43.120000 --> 0:05:44.960000
 It's your responsibility.

0:05:44.960000 --> 0:05:48.240000
 That is called the customer
 premises equipment.

0:05:48.240000 --> 0:05:52.220000
 In this particular terminology or in
 this diagram here, that would consist

0:05:52.220000 --> 0:05:56.360000
 of the router and then that router
 is connected to some kind of a box.

0:05:56.360000 --> 0:05:59.080000
 And we'll talk about what that
 box is here in just a minute.

0:05:59.080000 --> 0:06:01.280000
 And those two things are your
 job, your responsibility.

0:06:01.280000 --> 0:06:03.540000
 So that is the customer
 premises equipment.

0:06:03.540000 --> 0:06:06.860000
 Now, there's going to be a line that
 runs into your house or into your

0:06:06.860000 --> 0:06:10.260000
 building and that line is going
 to stop at some point.

0:06:10.260000 --> 0:06:14.440000
 And the telephone company is going to
 say, okay, if anything goes wrong,

0:06:14.440000 --> 0:06:18.840000
 we're responsible for fixing
 it from this point on.

0:06:18.840000 --> 0:06:23.740000
 So from this point, this jack or this
 wall plate in your wall and the

0:06:23.740000 --> 0:06:28.080000
 line that goes outside of your building
 to us will take care of any problems.

0:06:28.080000 --> 0:06:32.000000
 But beyond that point, you have to take
 care of the problem if the problem

0:06:32.000000 --> 0:06:32.920000
 is on the other side.

0:06:32.920000 --> 0:06:35.940000
 That point is called the
 demarcation point.

0:06:35.940000 --> 0:06:38.720000
 Otherwise, frequently
 known as the demarc.

0:06:38.720000 --> 0:06:42.380000
 So the demarc would typically look like
 some sort of wall jack or plate

0:06:42.380000 --> 0:06:46.480000
 or maybe some sort of embedded box in
 your wall where the wires from the

0:06:46.480000 --> 0:06:49.500000
 outside world is coming in and
 terminating right there.

0:06:49.500000 --> 0:06:51.740000
 That is the demarcation point.

0:06:51.740000 --> 0:06:56.300000
 Now the local loop is the actual physical
 wire that's going from the demarcation

0:06:56.300000 --> 0:07:00.280000
 point out to the telephone
 company's buildings.

0:07:00.280000 --> 0:07:05.960000
 So that local loop is probably a few
 miles long, but that is the local

0:07:05.960000 --> 0:07:09.620000
 loop. Is that actual wire that's strung
 up on the telephone poles or maybe

0:07:09.620000 --> 0:07:12.400000
 buried underneath the ground that goes
 between your house and your building

0:07:12.400000 --> 0:07:15.160000
 to the telephone company's
 building?

0:07:15.160000 --> 0:07:18.100000
 And now technically where that wire
 terminates to the other end, what

0:07:18.100000 --> 0:07:21.520000
 I've been calling the telephone company's
 building, the technical term

0:07:21.520000 --> 0:07:23.820000
 for that is the central office.

0:07:23.820000 --> 0:07:29.780000
 So we have here, if we take a look at
 all this, we have the central office,

0:07:29.780000 --> 0:07:33.400000
 they have a wire which
 is the local loop.

0:07:33.400000 --> 0:07:37.080000
 That wire terminates at some point where
 they say beyond this point, if

0:07:37.080000 --> 0:07:39.320000
 there's a problem it's
 your job to fix it.

0:07:39.320000 --> 0:07:40.840000
 That's the demarcation.

0:07:40.840000 --> 0:07:45.740000
 And then everything over here is
 the customer premises equipment.

0:07:45.740000 --> 0:07:52.040000
 Okay, so let's now talk a little bit
 more about this thing right here.

0:07:52.040000 --> 0:07:56.960000
 This box, what is that
 and why do we need it?

0:07:56.960000 --> 0:08:01.960000
 So in this type of scenario where we
 have a T1 line or if you're in Europe

0:08:01.960000 --> 0:08:08.380000
 in E1 line that's connecting into your
 company, that box would be what

0:08:08.380000 --> 0:08:14.560000
 we call a CSU, DSU or a channel
 service unit, data service unit.

0:08:14.560000 --> 0:08:19.180000
 And this is the fundamental device
 that connects their circuit, their

0:08:19.180000 --> 0:08:23.940000
 line to your customer premises equipment,
 which is probably a router,

0:08:23.940000 --> 0:08:29.280000
 your router. So connects DTE equipment,
 which is routers, to the digital

0:08:29.280000 --> 0:08:34.580000
 lines. So even though it has two acronyms,
 channel service unit, data

0:08:34.580000 --> 0:08:39.280000
 service units, one physical box, but
 we can sort of logically imagine

0:08:39.280000 --> 0:08:43.560000
 the box being separated into
 two functional pieces.

0:08:43.560000 --> 0:08:48.360000
 So some of the hardware in that box
 is designed to connect to the DTE

0:08:48.360000 --> 0:08:51.940000
 equipment. It's designed to
 connect to your router.

0:08:51.940000 --> 0:08:55.320000
 So that is the data service unit.

0:08:55.320000 --> 0:08:58.820000
 So the DSU connects to
 your router to the DTE.

0:08:58.820000 --> 0:09:02.360000
 Some other components within that same
 box, some other transistors and

0:09:02.360000 --> 0:09:06.700000
 wires and buttons and jacks and everything
 connect to that cable that

0:09:06.700000 --> 0:09:09.040000
 the telephone company has
 run into your building.

0:09:09.040000 --> 0:09:12.100000
 That is called the channel
 service unit.

0:09:12.100000 --> 0:09:14.400000
 Now, why do we need this thing?

0:09:14.400000 --> 0:09:15.220000
 What's the purpose of it?

0:09:15.220000 --> 0:09:20.480000
 Well, I'd create some whiteboards here
 that I want to help explain this.

0:09:20.480000 --> 0:09:26.540000
 So back in the day, if you had a router
 and you need to connect it to

0:09:26.540000 --> 0:09:29.100000
 a T1 line, you had
 to buy a CSU DSU.

0:09:29.100000 --> 0:09:30.400000
 And why was that?

0:09:30.400000 --> 0:09:35.040000
 Well, because on the router, your LAN
 interfaces were RJ45 interfaces.

0:09:35.040000 --> 0:09:36.520000
 They were Ethernet.

0:09:36.520000 --> 0:09:38.260000
 And Ethernet doesn't talk.

0:09:38.260000 --> 0:09:42.080000
 Ethernet was not designed for
 wide area network protocols.

0:09:42.080000 --> 0:09:43.240000
 It doesn't do that.

0:09:43.240000 --> 0:09:46.440000
 So you had another type of interface on
 your router called a WAN interface,

0:09:46.440000 --> 0:09:52.080000
 which might take the form
 of an RS-232 interface.

0:09:52.080000 --> 0:09:56.700000
 And for example, if you have not seen
 an RS-232, there's a picture of

0:09:56.700000 --> 0:09:58.580000
 what one looks like.

0:09:58.580000 --> 0:10:02.080000
 You know, as the type of interface has
 got lots of different pins in it.

0:10:02.080000 --> 0:10:07.300000
 And the point of an RS-232, as you can
 see here, lots of different wires,

0:10:07.300000 --> 0:10:12.820000
 lots of different pins, each with its
 own distinct, separate functionality,

0:10:12.820000 --> 0:10:14.620000
 its own purpose.

0:10:14.620000 --> 0:10:18.320000
 Now for the purpose of this video and
 for the CCT, you don't need to know

0:10:18.320000 --> 0:10:20.080000
 what all these pins do.

0:10:20.080000 --> 0:10:25.780000
 For example, clear to send,
 data set ready to send.

0:10:25.780000 --> 0:10:29.020000
 You don't need to know what those acronyms
 mean or why they're there.

0:10:29.020000 --> 0:10:32.900000
 The main takeaway I want you to have
 right now is that your RS-232, this

0:10:32.900000 --> 0:10:38.180000
 is your serial interface, on your router,
 has lots of different pins and

0:10:38.180000 --> 0:10:41.900000
 each pin is actually connecting to a
 physical wire inside of a cable and

0:10:41.900000 --> 0:10:44.440000
 each pin is doing its
 own unique thing.

0:10:44.440000 --> 0:10:48.160000
 However, the wire that's coming into
 your office that's carrying that

0:10:48.160000 --> 0:10:52.660000
 T1 line is coming in
 on an RJ48 interface.

0:10:52.660000 --> 0:10:55.520000
 That only has six wires
 inside of it.

0:10:55.520000 --> 0:10:58.300000
 Well, only six of them
 are actually used.

0:10:58.300000 --> 0:11:02.060000
 So right here, you can see there's, we
 need something to translate because

0:11:02.060000 --> 0:11:08.140000
 on the one hand, our router has a connector
 that's got like 15, 20 different

0:11:08.140000 --> 0:11:13.100000
 connectors in it, different pins and
 that certainly cannot connect to

0:11:13.100000 --> 0:11:16.200000
 another wire that's only
 got six pins in it.

0:11:16.200000 --> 0:11:17.340000
 That's not going to work.

0:11:17.340000 --> 0:11:19.900000
 The two wires just won't connect.

0:11:19.900000 --> 0:11:23.700000
 So we had a need to put something in
 the middle here that can connect

0:11:23.700000 --> 0:11:25.940000
 to these two different connectors.


0:11:25.940000 --> 0:11:28.740000
 Not only that. Okay.

0:11:28.740000 --> 0:11:30.360000
 Look at the signal levels here.

0:11:30.360000 --> 0:11:34.100000
 Now you don't need to know what's a one
 and what's a zero as far as voltage

0:11:34.100000 --> 0:11:35.280000
 levels are concerned.

0:11:35.280000 --> 0:11:40.720000
 But I've drawn this in a very specific
 way to indicate that your serial

0:11:40.720000 --> 0:11:47.280000
 interface, your voltage levels are
 about that high and but the voltage

0:11:47.280000 --> 0:11:52.280000
 levels coming in off of the
 T1 are about that high.

0:11:52.280000 --> 0:11:57.700000
 Because remember, keep in mind, the
 WAN circuit, the T1 line has to be

0:11:57.700000 --> 0:12:02.880000
 able to put a one or a zero on a wire
 and have that one or zero go for

0:12:02.880000 --> 0:12:07.660000
 possibly miles down that wire
 and still be recognized.

0:12:07.660000 --> 0:12:12.840000
 That electrical pulse still has to
 be recognizable as a one or a zero,

0:12:12.840000 --> 0:12:17.640000
 five, 10, 15 miles down the wire when
 it terminates at the demarcation

0:12:17.640000 --> 0:12:21.840000
 point. So we need a lot more electrical
 energy to push that down the wire

0:12:21.840000 --> 0:12:23.760000
 so it doesn't get degraded.

0:12:23.760000 --> 0:12:27.880000
 But a serial interface on a router
 was never designed to connect to a

0:12:27.880000 --> 0:12:32.000000
 wire that goes three, four,
 five, 10, 15 miles.

0:12:32.000000 --> 0:12:33.580000
 It wasn't designed for that.

0:12:33.580000 --> 0:12:36.440000
 So a serial interface, when it's pumping
 out its voltage levels for ones

0:12:36.440000 --> 0:12:41.020000
 and zeros, that voltage level is much
 less than the voltage level used

0:12:41.020000 --> 0:12:44.640000
 in your T1. So that's another reason
 why we need something in the middle

0:12:44.640000 --> 0:12:48.140000
 here to be able to handle these different
 voltage levels and translate

0:12:48.140000 --> 0:12:56.480000
 between them. And then lastly, notice
 that on the left, on the RS-232

0:12:56.480000 --> 0:13:00.220000
 interface, I mentioned that we have
 these dedicated wires that are used

0:13:00.220000 --> 0:13:02.160000
 just for signaling.

0:13:02.160000 --> 0:13:05.240000
 So for example, here I have my wire
 that's just for my transmit.

0:13:05.240000 --> 0:13:06.940000
 That's for my transmitting
 and my data.

0:13:06.940000 --> 0:13:13.220000
 But this other stuff, RTS, CTS, clocking,
 DCD, that's not concerned with

0:13:13.220000 --> 0:13:14.680000
 actually carrying the data.

0:13:14.680000 --> 0:13:16.580000
 That's not carrying your
 ethernet frames.

0:13:16.580000 --> 0:13:19.340000
 That's not carrying your web
 browsing or your telnet.

0:13:19.340000 --> 0:13:22.440000
 That's carrying signaling
 or control information.

0:13:22.440000 --> 0:13:24.740000
 Can I go? Do I need to stop?

0:13:24.740000 --> 0:13:26.060000
 Hold on a second.

0:13:26.060000 --> 0:13:30.000000
 Pause. That's all the types of signaling
 that these wires are carrying

0:13:30.000000 --> 0:13:32.740000
 on completely separate wires.

0:13:32.740000 --> 0:13:37.900000
 But in a T1, signaling is actually embedded
 in the exact same wires, the

0:13:37.900000 --> 0:13:42.300000
 exact same cables that your data
 is being transmitted on.

0:13:42.300000 --> 0:13:46.480000
 So as 1s and 0s are coming in at these
 really high voltage levels, some

0:13:46.480000 --> 0:13:48.420000
 of them carry your data.

0:13:48.420000 --> 0:13:52.540000
 But some of those 1s and 0s right next
 to it are interpreted completely

0:13:52.540000 --> 0:13:56.060000
 differently as signaling
 bits or control bits.

0:13:56.060000 --> 0:14:01.060000
 So that's another reason why we need
 our CSUDSU to be able to interpret

0:14:01.060000 --> 0:14:05.400000
 between signaling that's on separate
 pins and separate wires as opposed

0:14:05.400000 --> 0:14:09.340000
 to signaling it's being embedded
 within the signal itself.

0:14:09.340000 --> 0:14:15.220000
 So the long and short of it is to say
 that the CSUDSU is a box, and you

0:14:15.220000 --> 0:14:18.740000
 can see here an example of what one
 of them looks like, that translates

0:14:18.740000 --> 0:14:24.460000
 or converts the signal coming in from
 a digital line like a T1 or E1 into

0:14:24.460000 --> 0:14:29.060000
 something that your RS-232 serial interface
 on your router can actually

0:14:29.060000 --> 0:14:34.060000
 understand. Now one other thing about
 the CSUDSU I want to point out that

0:14:34.060000 --> 0:14:39.940000
 was on the blueprint for X, they want
 you to know what a loopback test

0:14:39.940000 --> 0:14:46.680000
 is. Okay so let's say that I'm
 back here and I have a problem.

0:14:46.680000 --> 0:14:48.900000
 I'm not getting any
 data through here.

0:14:48.900000 --> 0:14:50.960000
 Everything seems to be set up.

0:14:50.960000 --> 0:14:55.680000
 The telco has told me that they've set
 up my circuit and yet I can't get

0:14:55.680000 --> 0:15:00.400000
 any data through this router to my office
 at the other end of the T1 which

0:15:00.400000 --> 0:15:04.260000
 is in Boston or in New York
 City or Lando or something.

0:15:04.260000 --> 0:15:06.400000
 I'm just not able to reach them.

0:15:06.400000 --> 0:15:10.240000
 Or maybe I am able to reach them but there's
 a lot of noise on the circuit.

0:15:10.240000 --> 0:15:11.820000
 It's really slow.

0:15:11.820000 --> 0:15:13.300000
 I'm getting a lot of delay.

0:15:13.300000 --> 0:15:15.700000
 A lot of the bits are
 having to be reset.

0:15:15.700000 --> 0:15:18.700000
 And I'm wondering okay
 where is the problem?

0:15:18.700000 --> 0:15:21.380000
 Is the problem on my
 serial interface?

0:15:21.380000 --> 0:15:23.340000
 Is the problem with this cable?

0:15:23.340000 --> 0:15:28.160000
 Could the problem possibly be my CSUDSU
 is messed up and I need to get

0:15:28.160000 --> 0:15:34.140000
 another one? Or could the problem be
 beyond my DMARC and into the realm

0:15:34.140000 --> 0:15:35.820000
 of responsibility of the telco?

0:15:35.820000 --> 0:15:38.240000
 Could it be on their line
 or something like that?

0:15:38.240000 --> 0:15:43.160000
 That's where we would use loopback tests
 to try to identify and isolate

0:15:43.160000 --> 0:15:45.340000
 where that problem is.

0:15:45.340000 --> 0:15:48.620000
 So there's two different
 kinds of loopback tests.

0:15:48.620000 --> 0:15:50.400000
 Software and hardware.

0:15:50.400000 --> 0:15:55.280000
 So the main sort of idea behind a loopback
 test is we're going to do something

0:15:55.280000 --> 0:16:01.920000
 somewhere so that when I send my bits
 out I know exactly where they stop

0:16:01.920000 --> 0:16:04.420000
 and they're loopback to me.

0:16:04.420000 --> 0:16:08.120000
 So in other words when I send a bit out
 I know that I've at this particular

0:16:08.120000 --> 0:16:11.820000
 point this point knows it needs to
 take that bit and basically reflect

0:16:11.820000 --> 0:16:13.920000
 it right back to me again.

0:16:13.920000 --> 0:16:17.540000
 So if I can send bits out and I get those
 same bits back I know that everything

0:16:17.540000 --> 0:16:20.160000
 from here to here is okay.

0:16:20.160000 --> 0:16:22.440000
 Then I can move my loopback maybe
 a little bit further out.

0:16:22.440000 --> 0:16:26.400000
 And now if I send bits and I don't
 get anything back well I know okay

0:16:26.400000 --> 0:16:29.720000
 it's between this point and
 this point right here.

0:16:29.720000 --> 0:16:31.720000
 So that's what we're
 talking about.

0:16:31.720000 --> 0:16:33.760000
 So there's two different
 kinds of loopback tests.

0:16:33.760000 --> 0:16:38.940000
 Software loopbacks and hardware loopbacks
 and where can they be implemented?

0:16:38.940000 --> 0:16:44.300000
 Well within the CSU DSU or within the
 telcos connection to your CSU DSU.

0:16:44.300000 --> 0:16:50.600000
 As an example. Let's say I had a physical
 CSU DSU like that box that we

0:16:50.600000 --> 0:16:54.560000
 just saw that's like so big on the slide
 just a second ago and I've got

0:16:54.560000 --> 0:16:58.160000
 that sitting at my table and that's
 connected to my router.

0:16:58.160000 --> 0:17:02.320000
 Well one thing I could do is on the
 CSU DSU there's probably a button

0:17:02.320000 --> 0:17:07.340000
 I can press or maybe a digital keypad
 I can type something in which will

0:17:07.340000 --> 0:17:09.960000
 cause the CSU DSU to
 perform a loopback.

0:17:09.960000 --> 0:17:16.820000
 So if I press that button then that
 means that the received side of the

0:17:16.820000 --> 0:17:20.380000
 DSU is loopback to
 the transmit side.

0:17:20.380000 --> 0:17:25.740000
 So once I press that button or take
 whatever that action is on the CSU

0:17:25.740000 --> 0:17:30.220000
 DSU. Now what I can do is I can say okay
 this right here is some interface

0:17:30.220000 --> 0:17:35.200000
 like serial 0 slash
 0 on my router.

0:17:35.200000 --> 0:17:39.080000
 And that interface has
 some IP address on it.

0:17:39.080000 --> 0:17:41.560000
 Let's just say 1.1.1.1.

0:17:41.560000 --> 0:17:45.760000
 Okay now they performed a loopback so
 this would be a hardware loopback

0:17:45.760000 --> 0:17:50.340000
 within the CSU DSU itself because I'm
 actually using its internal circuitry

0:17:50.340000 --> 0:17:54.760000
 to do this. Then I would just ping
 myself with an extended ping.

0:17:54.760000 --> 0:18:00.340000
 Do like several thousands of pings
 to 1111 which is yourself.

0:18:00.340000 --> 0:18:04.320000
 Now if I don't get those pings back
 or if I'm only getting some of them

0:18:04.320000 --> 0:18:07.240000
 back. Hey I know it's not
 the telcos problem now.

0:18:07.240000 --> 0:18:12.260000
 Now the problem is either with the
 cable itself or with the CSU DSU.

0:18:12.260000 --> 0:18:18.560000
 If I suspect now I could narrow it down
 even further a hardware loopback

0:18:18.560000 --> 0:18:23.640000
 would be simply meaning okay let me
 just unplug this cable entirely.

0:18:23.640000 --> 0:18:27.520000
 And I'll actually take the end
 of that cable cut it off.

0:18:27.520000 --> 0:18:32.080000
 I'll pull out the wires and I will
 physically attach the receive wire

0:18:32.080000 --> 0:18:33.520000
 to the transmit wire.

0:18:33.520000 --> 0:18:34.980000
 I will twist them together.

0:18:34.980000 --> 0:18:38.620000
 Now I've created another type of a
 hardware loopback that doesn't even

0:18:38.620000 --> 0:18:40.940000
 involve my CSU DSU at all.

0:18:40.940000 --> 0:18:45.960000
 It's like a similar analogy would be
 taking a switch, an ethernet switch

0:18:45.960000 --> 0:18:49.680000
 and taking a crossover cable for one
 port and connecting it to another

0:18:49.680000 --> 0:18:51.780000
 port on that exact same switch.

0:18:51.780000 --> 0:18:54.980000
 Except here I've got one cable coming
 out and on the end I've twisted

0:18:54.980000 --> 0:18:57.800000
 the wires together creating
 a loopback.

0:18:57.800000 --> 0:19:03.540000
 Now when I ping myself if the ping is
 fine I say oh okay when I did the

0:19:03.540000 --> 0:19:06.960000
 loopback test on the CSU DSU
 my pings were messed up.

0:19:06.960000 --> 0:19:10.600000
 I wasn't getting them but when I removed
 the CSU DSU and I actually physically

0:19:10.600000 --> 0:19:14.720000
 twisted the wires of the cable
 together my ping is working.

0:19:14.720000 --> 0:19:18.760000
 That tells me the CSU
 DSU is at fault.

0:19:18.760000 --> 0:19:25.020000
 Also you might say okay well the CSU
 DSU is a two part box right it's

0:19:25.020000 --> 0:19:26.840000
 got a DSU and a CSU.

0:19:26.840000 --> 0:19:31.760000
 When you press that button
 on here it was doing this.

0:19:31.760000 --> 0:19:34.680000
 There's another way you could do is
 you could say all right let me take

0:19:34.680000 --> 0:19:40.340000
 this cable out right here let me take
 that one out and put a wire in there

0:19:40.340000 --> 0:19:42.840000
 and loop loop that back.

0:19:42.840000 --> 0:19:49.200000
 Now it's testing not only the DSU portion
 but the CSU portion as well.

0:19:49.200000 --> 0:19:52.400000
 Now let's say I do all that that's
 that's the extent to what I can do

0:19:52.400000 --> 0:19:56.180000
 and my pings work all along
 the way my pings work.

0:19:56.180000 --> 0:20:01.100000
 So my cable connecting to the CSU DSU
 is okay both the DSU and the CSU

0:20:01.100000 --> 0:20:04.280000
 portions of that box are okay.

0:20:04.280000 --> 0:20:09.680000
 At that point the next step in the line
 would be to get the telco involved.

0:20:09.680000 --> 0:20:12.920000
 You'd have to call them on the line
 and say hey can you put your circuit

0:20:12.920000 --> 0:20:15.720000
 into a loopback for me because
 I need to do some testing.

0:20:15.720000 --> 0:20:17.420000
 And that's exactly
 what they would do.

0:20:17.420000 --> 0:20:21.100000
 So if they do that they would go on to
 their WAN switch their telco switch

0:20:21.100000 --> 0:20:28.260000
 and they would take the receive and
 loop it back to the transmit.

0:20:28.260000 --> 0:20:33.260000
 And now if I do my ping test and it fails
 I know okay the problem is here

0:20:33.260000 --> 0:20:38.180000
 it's on this wire or it's on the WAN
 switch it's but so these loopback

0:20:38.180000 --> 0:20:43.120000
 tests are ways of identifying
 where the circuit is broken.

0:20:43.120000 --> 0:20:45.740000
 And like I said there's
 software or hardware.

0:20:45.740000 --> 0:20:47.920000
 Now in this particular case pretty much
 everything I've been describing

0:20:47.920000 --> 0:20:49.800000
 has been hardware loopbacks.

0:20:49.800000 --> 0:20:55.060000
 A lot of Cisco routers these days have
 CSU DSUs actually built inside

0:20:55.060000 --> 0:20:56.320000
 the router itself.

0:20:56.320000 --> 0:21:00.240000
 Like you'll actually see the router
 has an RJ48 interface that connects

0:21:00.240000 --> 0:21:05.740000
 right to the D-mark and internal
 to the router it has a CSU DSU.

0:21:05.740000 --> 0:21:08.860000
 You'll actually see on the RJ48 interface
 of the router you'll see CSU

0:21:08.860000 --> 0:21:10.960000
 DSU across the top of it.

0:21:10.960000 --> 0:21:15.460000
 So you could still do a hardware loopback
 by putting a special plug or

0:21:15.460000 --> 0:21:19.740000
 a special cable in there that's loopback
 or you could actually go on to

0:21:19.740000 --> 0:21:24.860000
 that T1 interface in your Cisco iOS software
 and type in a loopback command.

0:21:24.860000 --> 0:21:30.120000
 For example the command might be loopback
 local or loopback T1 or something

0:21:30.120000 --> 0:21:32.700000
 like that but it's an interface
 level command.

0:21:32.700000 --> 0:21:37.120000
 And that's programming the internal
 CSU DSU to loopback to itself and

0:21:37.120000 --> 0:21:40.480000
 that's what we call
 a software loopback.

0:21:40.480000 --> 0:21:44.480000
 So that concludes this
 section of this video.